03-14-2023 Agenda Packet
MEETING AGENDA
City Council
REGULAR SESSION CITY COUNCIL
March 14, 2023
HAL BALDWIN MUNICIPAL COMPLEX COUNCIL CHAMBERS
1400 SCHERTZ PARKWAY BUILDING #4
SCHERTZ, TEXAS 78154
CITY OF SCHERTZ CORE VALUES
Do the right thing
Do the best you can
Treat others the way you want to be treated
Work cooperatively as a team
AGENDA
TUESDAY, MARCH 14, 2023 at 6:00 p.m.
Call to Order
Opening Prayer and Pledges of Allegiance to the Flags of the United States and State of Texas
(Councilmember Scagliola)
Proclamations:
National Procurement Month March 2023
City Events and Announcements
Announcements of upcoming City Events (B. James/S. Gonzalez)
Announcements and recognitions by the City Manager (S. Williams)
Announcements and recognitions by the Mayor (R. Gutierrez)
Hearing of Residents
This time is set aside for any person who wishes to address the City Council. Each person should fill
out the speaker’s register prior to the meeting. Presentations should be limited to no more than 3
minutes.
All remarks shall be addressed to the Council as a body, and not to any individual member thereof.
Any person making personal, impertinent, or slanderous remarks while addressing the Council
may be requested to leave the meeting.
March 14, 2023 City Council Agenda Page 1
Discussion by the Council of any item not on the agenda shall be limited to statements of specific
factual information given in response to any inquiry, a recitation of existing policy in response to an
inquiry, and/or a proposal to place the item on a future agenda. The presiding officer, during the
Hearing of Residents portion of the agenda, will call on those persons who
have signed up to speak in the order they have registered.
Consent Agenda Items
The Consent Agenda is considered self-explanatory and will be enacted by the Council with one
motion. There will be no separate discussion of these items unless they are removed from the Consent
Agenda upon the request of the Mayor or a Councilmember.
1.Minutes – Consideration and/or action regarding the approval of the following minutes from
the regular meeting on March 7, 2023. (S. Edmondson/S.Courney)
2.Appointment/Reappointment For Boards/Commissions/Committees (S.Edmondson)
Accept resignation of Patricia Barnes of the Schertz Historical Preservation
Committee.
3.Resolution 23-R-28 - Consideration and/or action by the City Council of the City of
Schertz, TX, approving a Resolution awarding a contract to Linebarger, Goggan, Blair &
Sampson, LLP for court collection agency services (S. Gonzalez/J. Walters)
4.Resolution 23-R-16 - Consideration and/or action by the City Council of the City of
Schertz, Texas approving amended and restated Bylaws of the Schertz Economic
Development Corporation; and other matters therewith. (B. James/H. Malish)
5.Resolution 23-R-24 - Consideration and/or action by the City Council of the City of
Schertz, Texas, authorizing the City Manager to enter into Standard Utility Agreement with
the State of Texas for the relocation of utilities – specifically the Riata Lift Station – along
IH 35 in preparation for the IH 35 NEX Project. (B.James/K.Woodlee/E.Schulze)
Discussion and Action Items
6.Ordinance 23-S-07- Consideration and/or action by the City Council of the City of Schertz,
Texas on an Ordinance to amend Part III, Schertz Code of Ordinances, the Unified
Development Code (UDC) Article 5 Zoning Districts, Subsections 21.5.2, 21.5.5 and
21.5.11; Article 9 Site Design Standards, Subsection 21.9.7 and 21.9.10; Article 10 Parking
Standards, Subsections 21.10.2, 21.10.3, 21.10.4, 21.10.7.C and 21.10.9; and Article 14
Transportation, Subsection 21.14.3. (Final Reading) (B. James/S. Williams)
Closed Session
March 14, 2023 City Council Agenda Page 2
7.The City Council will meet in closed session in accordance with Section 551.072, Texas
Government Code deliberation regarding the purchase, exchange, lease, or value of Real
Property for future roadways, roadway extensions, and roadway expansions.
Reconvene into Regular Session
Roll Call Vote Confirmation
Information available in City Council Packets - NO DISCUSSION TO OCCUR
Requests and Announcements
Announcements by the City Manager
Requests by Mayor and Councilmembers for updates or information from Staff
Requests by Mayor and Councilmembers that items or presentations be placed on a future City
Council agenda
Announcements by Mayor and Councilmembers
City and Community Events attended and to be attended
City Council Committee and Liaison Assignments (see assignments below)
Continuing Education Events attended and to be attended
Recognition of actions by City Employees
Recognition of actions by Community Volunteers
Adjournment
CERTIFICATION
I, SHEILA EDMONDSON, CITY SECRETARY OF THE CITY OF SCHERTZ, TEXAS, DO HEREBY CERTIFY THAT
THE ABOVE AGENDA WAS PREPARED AND POSTED ON THE OFFICIAL BULLETIN BOARDS ON THIS THE
10th DAY OF MARCH 2023 AT 7:00 P.M., WHICH IS A PLACE READILY ACCESSIBLE TO THE PUBLIC AT ALL
TIMES AND THAT SAID NOTICE WAS POSTED IN ACCORDANCE WITH CHAPTER 551, TEXAS GOVERNMENT
CODE.
SHEILA EDMONDSON
I CERTIFY THAT THE ATTACHED NOTICE AND AGENDA OF ITEMS TO BE CONSIDERED BY THE CITY
COUNCIL WAS REMOVED BY ME FROM THE OFFICIAL BULLETIN BOARD ON _____DAY OF
_______________, 2023.
TITLE: ___________________________________
This facility is accessible in accordance with the Americans with Disabilities Act. Handicapped parking spaces are available.
If you require special assistance or have a request for sign interpretative services or other services, please call 210-619-1030.
The City Council for the City of Schertz reserves the right to adjourn into closed session at any time during the course
of this meeting to discuss any of the matters listed above, as authorized by the Texas Open Meetings Act.
Closed Sessions Authorized: This agenda has been reviewed and approved by the City’s legal counsel and the presence
March 14, 2023 City Council Agenda Page 3
Closed Sessions Authorized: This agenda has been reviewed and approved by the City’s legal counsel and the presence
of any subject in any Closed Session portion of the agenda constitutes a written interpretation of Texas Government
Code Chapter 551 by legal counsel for the governmental body and constitutes an opinion by the attorney that the items
discussed therein may be legally discussed in the closed portion of the meeting considering available opinions of a
court of record and opinions of the Texas Attorney General known to the attorney. This provision has been added to
this agenda with the intent to meet all elements necessary to satisfy Texas Government Code Chapter 551.144(c) and
the meeting is conducted by all participants in reliance on this opinion.
COUNCIL COMMITTEE AND LIAISON ASSIGNMENTS
Mayor Gutierrez
Audit Committee
Board of Adjustments
Investment Advisory Committee
Main Street Committee
Senior Center Advisory Board-Alternate
Councilmember Davis– Place 1
Interview Committee for Boards and Commissions
Main Street Committee - Chair
Parks & Recreation Advisory Board
Schertz Housing Authority Board
Transportation Safety Advisory Commission
TIRZ II Board
Councilmember Watson - Place 2
Audit Committee
Library Advisory Board
Senior Center Advisory Board
Cibolo Valley Local Government Corporation-Alternate
Councilmember Whittaker – Place 3
Historical Preservation Committee
Interview Committee for Boards and Commissions
TIRZ II Board
Councilmember Dahle – Place 4
Cibolo Valley Local Government Corporation
Interview Committee for Boards and Commissions
Planning & Zoning Commission
TIRZ II Board
Councilmember Scagliola – Place 5
Animal Advisory Commission - Alternate
Hal Baldwin Scholarship Committee
Schertz-Seguin Local Government Corporation
Councilmember Heyward – Place 6
Animal Advisory Commission
Audit Committee
Building and Standards Commission
Economic Development Corporation - Alternate
Investment Advisory Committee
Main Street Committee
Interview Committee for Boards and Commissions-Alternate
Senior Center Advisory Board-Alternate
Councilmember Brown – Place 7
Economic Development Corporation
Main Street Committee
Schertz-Seguin Local Government Corporation - Alternate
March 14, 2023 City Council Agenda Page 4
Agenda No.
CITY COUNCIL MEMORANDUM
City Council Meeting:March 14, 2023
Department:City Secretary
Subject:Proclamations:
National Procurement Month March 2023
Agenda No. 1.
CITY COUNCIL MEMORANDUM
City Council
Meeting:March 14, 2023
Department:City Secretary
Subject:Minutes – Consideration and/or action regarding the approval of the following
minutes from the regular meeting on March 7, 2023. (S. Edmondson/S.Courney)
Agenda No. 3.
CITY COUNCIL MEMORANDUM
City Council
Meeting:March 14, 2023
Department:Finance
Subject:Resolution 23-R-28 - Consideration and/or action by the City Council of the City
of Schertz, TX, approving a Resolution awarding a contract to Linebarger,
Goggan, Blair & Sampson, LLP for court collection agency services (S.
Gonzalez/J. Walters)
BACKGROUND
Linebarger Goggan Blair & Sampson, LLP (LGBS) has been representing the City of Schertz in the
collection of fees, fines and costs pursuant to Article 103 of the Code of Criminal Procedure since
March 2, 2012.
LGBS is fully qualified to provide this representation being the largest delinquent collection law firm in
the State of Texas, as well as the United States, having been engaged in this specialized legal service
for more than 40 years. In additional, LGBS possesses infrastructure and technology, such as a call
center technology that the City does not currently possess.
A collection fee of 30% of the fine amounts are added to delinquent accounts and are paid at the time
of collection. The city incurs no additional costs in utilizing the program as all the additional collection
fee goes to LGBS. Accounts are sent to LGBS 90 days after issuing a warrant.
With court staff being composed of four full time staff members; the assistance of this program has
been effective in aiding the court is resolving outstanding cases.
Legal services are considered exempt from procurement requirements as per Local Government Code
252.022
GOAL
To renew the existing collection services contract.
COMMUNITY BENEFIT
This is another way to provide for safe community by helping to hold defendants accountable.
SUMMARY OF RECOMMENDED ACTION
To approve this resolution and renew the existing contract with LGBS.
FISCAL IMPACT
In FY 2021-22, LGBS helped to collect $283,000 in municipal court fees and fines and received
In FY 2021-22, LGBS helped to collect $283,000 in municipal court fees and fines and received
$48,400 for their services at no additional cost to the City. The amount is less than the 30% of the total
fines as some accounts fees are waived in coordination with LGBS and the Judge varying on the
circumstances of the defendant and the case.
RECOMMENDATION
Staff recommends approval of Resolution 23-R-28
Attachments
Resolution 23-R-28
Exhibit A - Contract Terms
50077397.1 A-1
RESOLUTION NO. 23-R-28
A RESOLUTION BY THE CITY COUNCIL OF THE CITY OF
SCHERTZ, TEXAS AUTHORIZING A PROFESSIONAL SERVICES
AGREEMENT WITH LINEBAGER GOGGAN BLAIR & SAMPSON,
LLP.
WHEREAS, the City staff of the City of Schertz (the “City”) has determined that the City
requires professional services relating to fines and fees collection services; and
WHEREAS, City staff has determined that Linebarger Goggan Blair & Sampson, LLP is
uniquely qualified to provide such services for the City; and
WHEREAS, pursuant to Section 252.022(a)(4), the City is not required to seek bids or
proposals with respect to a procurement for personal, professional, or planning purposes; and
WHEREAS, pursuant to Section 2254.1036 of the Texas Government Code, the City of
Schertz City Council finds as follows:
1. There is a substantial need for the legal services to be provided pursuant to the
Contract for Fines and Fees Collection Services;
2. These legal services cannot be adequately performed by the employees and
supporting personnel of the City at a reasonable cost;
3. Linebarger Goggan Blair & Sampson, LLP has represented the City for the past
eleven (11) years with competence and professionalism, in the collection of
unpaid fines, fees and court costs beginning on March 2, 2012.
4. These legal services cannot reasonably be obtained from attorneys in private
practice under a contract providing only for the payment of hourly fees, without
regard to the outcome of the matter, because of the nature of t he collection fee
authorized by Tx Code of Criminal Procedure Art. 103.0031 and because the
City of Schertz does not have the funds to pay the estimated amounts required
under a contract only for the payment of hourly fees;
5. Linebarger Goggan Blair & Sampson LLP is well qualified and competent to
perform the legal services required to comply with the terms of this contract.
WHEREAS, the City Council has determined that it is in the best interest of the City to
contract with Linebarger Goggan Blair & Sampson, LLP pursuant to the Agreement attached
hereto as Exhibit A (the “Agreement”).
50077397.1 A-2
NOW THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF
SCHERTZ, TEXAS THAT:
Section 1. The City Council hereby authorizes the City Manager to execute and
deliver the Agreement with Linebarger Goggan Blair & Sampson, LLP in substantially the form
set forth on Exhibit A.
Section 2. The recitals contained in the preamble hereof are hereby found to be true,
and such recitals are hereby made a part of this Resolution for all purposes and are adopted as a
part of the judgment and findings of the City Council.
Section 3. All resolutions, or parts thereof, which are in conflict or inconsistent with
any provision of this Resolution are hereby repealed to the extent of such conflict, and the
provisions of this Resolution shall be and remain controlling as to the matters resolved herein.
Section 4. This Resolution shall be construed and enforced in accordance with the
laws of the State of Texas and the United States of America.
Section 5. If any provision of this Resolution or the application thereof to any person
or circumstance shall be held to be invalid, the remainder of this Resolution and the application
of such provision to other persons and circumstances shall nevertheless be valid, and the City
Council hereby declares that this Resolution would have been enacted without such invalid
provision.
Section 6. It is officially found, determined, and declared that the meeting at which
this Resolution is adopted was open to the public and public notice of the t ime, place, and subject
matter of the public business to be considered at such meeting, including this Resolution, was
given, all as required by Chapter 551, Texas Government Code, as amended.
Section 7. This Resolution shall be in force and effect from and after its final
passage, and it is so resolved.
PASSED AND ADOPTED, this 14th day of March, 2023.
CITY OF SCHERTZ, TEXAS
Ralph Gutierrez, Mayor
ATTEST:
Sheila Edmondsun, City Secretary
Contract for Fines and Fees Collection Services
STATE OF TEXAS
COUNTY OF GUADALUPE
THIS CONTRACT (hereinafter “AGREEMENT”) is made and entered into by and
between CITY OF SCHERTZ, acting herein by and through its governing body,
hereinafter styled “CLIENT”, and Linebarger Goggan Blair & Sampson, LLP, hereinafter
styled “FIRM”.
Article I
Nature of Relationship and Authority for Contract
1.01 The parties hereto acknowledge that this AGREEMENT creates an attorney -client
relationship between CLIENT and FIRM.
1.02 The CLIENT hereby employs the FIRM to provide the services hereinafter
described for compensation hereinafter provided.
1.03 This AGREEMENT is entered into pursuant to and as authorized by Subsection (a)
of ART. 103.0031, Texas Code of Criminal Procedure.
Article 2
Scope of Services
2.01 CLIENT agrees to employ and does hereby employ FIRM to provide specific legal
services provided herein and enforce the collection of delinquent court fees and fines
that are subject to this AGREEMENT, pursuant t o the terms and conditions described
herein. Such legal services shall include but not be limited to recommendations and
legal advice to CLIENT to take legal enforcement action; representing CLIENT in any
dispute or legal challenge over authority to collec t such court fees and fines; defending
CLIENT in litigation or challenges of its collection authority; and representing CLIENT in
collection interests in bankruptcy matters as determined by FIRM and CLIENT. This
AGREEMENT supersedes all prior oral and written agreements between the parties
regarding court fees and fines, and can only be amended if done so in writing and
signed by all parties. Furthermore, this contract cannot be transferred or assigned by
either party without the written consent of all parties.
2.02 The CLIENT may from time-to-time specify in writing additional actions that should
be taken by the FIRM in connection with the collection of the fines and fees that are
subject to this AGREEMENT. CLIENT further constitutes and appoints the FIRM as
CLIENT's attorneys to sign all legal instruments, pleadings, drafts, authorizations and
papers as shall be reasonably necessary to pursue collection of the CLIENT’s claims.
2.03 Fines and Fees are subject to this AGREEMENT pursuant to the terms of Art.
103.0031, Texas Code of Criminal Procedure [as amended by Senate Bill 782, 78th
Legislature (2003), effective June 18, 2003].
2.04 The CLIENT agrees to provide to the FIRM data regarding any fines and fees that
are subject to this AGREEMENT. The data shall be provided by electronic medium in a
file format specified by the FIRM. The CLIENT and the FIRM may from time -to-time
agree in writing to modify this format. The CLIENT shall provide the data to the FIRM
not less frequently than monthly.
2.05 The FIRM, in all communications seeking the collection of fines and fees, shall
direct all payments directly to the CLIENT at an address designated by the CLIENT. If
any fines and fees are paid to the FIRM, said payments shall be expeditiously turned
over to the CLIENT.
Article 3
Compensation
3.01 The CLIENT agrees to pay the FIRM as compensation for the services required
hereunder:
(a) Zero percent (0%) of all the fines and fees subject to the terms of this
AGREEMENT as set forth in Section 2.3 above that are col lected by the CLIENT
during the term of this AGREEMENT and that were incurred under Art.
103.0031(a)(2), Texas Code of Criminal Procedure, as a result of the commission of a
criminal or civil offense committed before June 18, 2003;
(b) Thirty percent (30%), pursuant to Article 103.0031(b), Texas Code of
Criminal Procedure, of all the fines and fees subject to the terms of this AGREEMENT
that are collected by the CLIENT during the term of this AGREEMENT and that were
incurred under Art. 103.0031(a)(2), Texas Code of Criminal Procedure, as a result of
the commission of a criminal or civil offense committed after June 18, 2003.
3.02 All compensation shall become the property of the FIRM at the time payment of
the fines and fees is made to the CLIENT.
3.03 The CLIENT shall pay the FIRM by the twentieth day of each month all
compensation earned by the FIRM for the previous month as provided in this Article 3.
The CLIENT shall provide an accounting showing all collections for the previous month
with the remittance.
Article 4
Intellectual Property Rights
4.01 The CLIENT recognizes and acknowledges that the FIRM owns all right, title and
interest in certain proprietary software that the FIRM may utilize in conjunction with
performing the services provided in this AGREEMENT. The CLIENT agrees and hereby
grants to the FIRM the right to use and incorporate any information provided by the
CLIENT ("CLIENT Information") to update the databases in this proprietary software,
and, notwithstanding that CLIENT Information has been or shall be used to update the
databases in this proprietary software, further stipulates and agrees that the CLIENT
shall have no rights or ownership whatsoever in and to the software or the data
contained therein, except that the CLIENT shall be entitled to obtain a copy of such data
that directly relates to the CLIENT’s accounts at any time.
4.02 The FIRM agrees that it will not share or disclose any specific confidential CLIENT
Information with any other company, individual, organization or agency, without the prior
written consent of the CLIENT, except as may be required by law or where such
information is otherwise publicly available. It is agreed that the FIRM shall have the right
to use CLIENT Information for internal analysis, improving the proprietary software and
database, and generating aggregate data and statistics that may inherently contain
CLIENT Information. These aggregate statistics are owned solely by the FIRM and will
generally be used internally, but may be shared with the FIRM's affiliates, partners or
other third parties for purposes of improving the FIRM's software and services.
Article 5
Costs
5.01 The FIRM and CLIENT recognize that certain costs may be incurred in the process
of providing any additional services contemplated in Section 2.02 above or in providing
any special litigation services. The CLIENT agrees that all such costs shall be billed to
the CLIENT, but that the FIRM will either (i) advance such costs on behalf of the
CLIENT or, (ii) when possible, arrange with the vendor or agency providing the service
that the costs of services will not be paid unless and until such costs are recovered by
the CLIENT from the debtor.
5.02 The CLIENT acknowledges that the FIRM may provide such services with its own
employees or with other entities or individuals who may be affiliated with the FIRM, but
the FIRM agrees that any charges for such services will be reasonable and consistent
with what the same services would cost if obtained from a third party.
5.03 The CLIENT agrees that upon the recovery of such costs, the CLIENT will (i) pay
the FIRM for any such costs that have been advanced by the FIRM or performed by the
FIRM and (ii) pay any third party agency or vendor owed for performing such services.
Article 6
Term and Termination
6.01 This AGREEMENT shall be effective February 28, 2023 (the “Effective Date”) and
shall expire on February 28, 2026 (the “Expiration Date”) unless extended as hereinafter
provided.
6.02 Unless prior to sixty (60) days before the Expiration Date, the CLIENT or the FIRM
notifies the other in writing that it does not wish to continue this AGREEMENT beyond
its initial term, this AGREEMENT shall be automatically extended for an additional one
(1) year period without the necessity of any further action by either party. In the absence
of any such sixty (60) day notice by either the CLIENT or the FIRM, the AGREEMENT
shall continue to automatically renew for additional and successive one -year terms in
the same manner at the end of each renewal period.
6.03 If, at any time during the initial term of this AGREEMENT or any extension hereof,
the CLIENT determines that the FIRM’s performance under this AGREEMENT is
unsatisfactory, the CLIENT shall notify the FIRM in writing of the CLIENT’s
determination. The notice from the CLIENT shall specify the particular deficiencies that
the CLIENT has observed in the FIRM’s performance. The FIRM shall have sixty (60)
days from the date of the notice to cure any such deficiencies. If, at the conclusion of
that sixty (60) day remedial period, the CLIENT remains unsatisfied with the FIRM’s
performance, the CLIENT may terminate this AGREEMENT effective upon the
expiration of thirty (30) days following the date of written notice to the FIRM of such
termination (“Termination Date”).
6.04 Whether this AGREEMENT expires or is terminated, the FIRM shall be entitled to
continue to collect any items and to pursue collection of any claims that were referred to
and placed with the FIRM by the CLIENT prior to the Termination Date or Expiration
Date for an additional ninety (90) days following termination or expiration. The CLIENT
agrees that the FIRM shall be compensated as provided by Article 3 for any such item
or pending matters during the ninety (90) day period.
6.05 The CLIENT agrees that the FIRM shall be reimbursed for any costs advanced and
shall be paid for any services performed pursuant to Article 5 when such costs are
recovered by or on behalf of the CLIENT, regardless of the date recovered. It is
expressly agreed that neither the expiration nor the termination of this AGREEMENT
constitutes a waiver by the FIRM of its entitlement to be reimbursed for such costs and
to be paid for such services. It is further expressly agreed that the expiration of any
ninety (90) day period under Section 6.04 does not constitute any such waiver by the
FIRM.
Article 7
Miscellaneous
7.01 Subcontracting. The FIRM may from time -to-time obtain co-counsel or subcontract
some of the services provided for herein to other law firms or entities. In such cases, the
FIRM will retain supervisory control and responsibility for any services provided by such
co-counsel or subcontractors and shall be responsible to pay any compensation due to
any such co-counsel or subcontractor.
7.02 Arbitration. Any controversy between the parties to this AGREEMENT involving the
construction or application of any of the terms, covenants, or conditions of this
AGREEMENT shall, on the written request of one party served on the other, be
submitted to arbitration, and such arbitration shall comply with and be governed by the
provisions of the Texas General Arbitration Act.
7.03 Integration. This AGREEMENT contains the entire AGREEMENT between the
parties hereto and may only be modified in a written amendment, executed by both
parties.
7.04 Representation of Other Governmental Entities. The CLIENT acknowledges and
consents to the representation by the FIRM of other governmental entities that may be
seeking the payment of fines and fees or other claims from the same person(s) a s the
CLIENT.
7.05 Notices. For purposes of sending any notice under the terms of this contract, all
notices from CLIENT shall be sent to FIRM by certified United States mail, or delivered
by hand or by courier, and addressed as follows:
Linebarger Goggan Blair & Sampson, LLP Linebarger Goggan Blair & Sampson, LLP
Attention: Director of CMS Attention: Clif Douglass
PO Box 17428 112 E. Pecan St., Suite 2200
Austin, Texas 78760-7428 San Antonio, Texas 78205
All notices from the FIRM to the CLIENT shall be sent to CLIENT by certified United
States mail, or delivered by hand or by courier, and addressed as follows:
City of Schertz
Attention: City Secretary
1400 Schertz Parkway, Bldg 2
Schertz, Texas 78154
7.06. Compliance with Tx. Govt. Code §2271.002. In order to comply with Tx. Govt.
Code §2271.002, the Firm verifies that it does not boycott Israel and will not boycott
Israel during the term of the contract.
7.07 Compliance with Tx. Govt. Code §2252.151- .154. In order to comply with Tx.
Govt. Code §2252.152, the Firm verifies that it is not a company identified on the Texas
Comptroller’s list of companies known to have contracts with, or provide supplies or
services to, a foreign organization designated as a Foreign Terrorist Organization by the
U.S. Secretary of State under federal law.
7.08 Compliance with Tx. Govt. Code §2274.001 - .002. In order to comply with Tx.
Govt. Code §2274.002, the Firm verifies that it does not boycott energy companies and
will not boycott energy companies during the term of the contract.
7.09 Compliance with Tx. Govt. Code §2274.001 - .002. In order to comply with Tx.
Govt. Code §2274.002, the Firm verifies that it does not have a practice, policy,
guidance, or directive that discriminates against a firearm entity or firearm trade
association; and, will not discriminate during the term of the contract against a firearm
entity or firearm trade association.
7.10 VALUE ADDED SERVICES. The FIRM agrees to provide to CLIENT with ACT
Lien Software at no cost to the CLIENT as long as this contract is in force.
EXECUTED ON the 7th day of March, 2023.
CITY OF SCHERTZ
By: __________________________________________
Steve Williams, City Manager
LINEBARGER GOGGAN BLAIR & SAMPSON, LLP
By: __________________________________________
Clifton Douglass, III, Managing Partner
For the FIRM
Agenda No. 4.
CITY COUNCIL MEMORANDUM
City Council
Meeting:March 14, 2023
Department:Economic Development Corporation
Subject:
Resolution 23-R-16 - Consideration and/or action by the City Council of the City
of Schertz, Texas approving amended and restated Bylaws of the Schertz
Economic Development Corporation; and other matters therewith. (B. James/H.
Malish)
BACKGROUND
City Council passed Ordinance 22-M-20 on May 10, 2022, changing term end dates for various boards
and commissions, including the Schertz Economic Develompent Corporation (SEDC). As a result, the
SEDC bylaws need to be updated. In addition to the proposed change for term end dates, staff is
proposing minor changes, including the addition of Chapter 22 of the Texas Business Organizations
Code, as a governing body based on City Attorney recommendation.
GOAL
To update the SEDC bylaws.
COMMUNITY BENEFIT
Provide consistent and clear bylaws for the operation of SEDC.
SUMMARY OF RECOMMENDED ACTION
Staff recommends approval of Resolution No. 23-R-16 to adopt the amended and restated Bylaws.
RECOMMENDATION
Staff recommends approval of Resolution No. 23-R-16.
Attachments
Resolution 23-R-16
SEDC Bylaws
Redline of changes
RESOLUTION NO. 23-R-16
A RESOLUTION BY THE CITY COUNCIL OF THE CITY OF
SCHERTZ, TEXAS, APPROVING AMENDED AND RESTATED
BYLAWS OF THE SCHERTZ ECONOMIC DEVELOPMENT
CORPORTION; AND OTHER MATTERS IN CONNECTION
THEREWITH
WHEREAS, the City Council (the "Council") of the City of Schertz, Texas (the "City")
has previously authorized the creation of the City of Schertz Economic Development
Corporation (the "Corporation") in accordance with the Development Corporation Act, as
amended, Title 12, Subtitle Cl, Texas Local Government Code (the "Act"); and
WHEREAS, on January 12, 2011, the Schertz City Council reviewed and approved the
existing Certificate of Formation and the existing Bylaws of the Corporation in Ordinance 11-M-
21; and
WHEREAS, the Schertz City Council took action on May 10, 2022, to change the term
end dates for City Boards, Commissions, and Committees in Ordinance 22-M-20; and
WHEREAS, the Board of Directors of the City of Schertz Economic Development
Corporation took action on February 23, 2023, to approve the proposed amendments to the
existing Bylaws of the Corporation in SEDC Resolution No. 2023-3; and
WHEREAS, the Schertz City Council have reviewed and approved the proposed
amendments to the existing Bylaws of the Corporation and has determined to authorize and
approve such amendments; and
WHEREAS, the Schertz City Council hereby finds and determines that the adoption of
this Resolution is in the best interests of the citizens of the City.
NOW, THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF
SCHERTZ, TEXAS THAT:
Section 1. The Schertz City Council hereby approves the amended Bylaws for the
Corporation in the form attached hereto as Exhibit A.
Section 2. The recitals contained in the preamble hereof are hereby found to be true, and
such recitals are hereby made a part of this Resolution for all purposes and are adopted as
a part of the judgment and findings of the City Council.
Section 3. All resolutions, or parts thereof, which are in conflict or inconsistent with any
provision of this Resolution are hereby repealed to the extent of such conflict, and the
provisions of this Resolution shall be and remain controlling as to the matters resolved
herein.
Section 4. This Resolution shall be construed and enforced in accordance with the laws
of the State of Texas and the United States of America.
Section 5. If any provision of this Resolution or the application thereof to any person or
circumstance shall be held to be invalid, the remainder of this Resolution and the
application of such provision to other persons and circumstances shall nevertheless be
valid, and the City Council hereby declares that this Resolution would have been enacted
without such invalid provision.
Section 6. It is officially found, determined, and declared that the meeting at which this
Resolution is adopted was open to the public and public notice of the time, place, and
subject matter of the public business to be considered at such meeting, including this
Resolution, was given, all as required by Chapter 551, Texas Government Code, as
amended.
Section 7. This Resolution shall be in force and effect from and after its final passage,
and it is so ordered.
PASSED AND ADOPTED, this 7th day of March, 2023.
CITY OF SCHERTZ, TEXAS
_______________________________
Ralph Gutierrez, Mayor
ATTEST:
________________________________
Sheila Edmondson, City Secretary
<City Seal>
EXHIBIT A
SCHERTZ ECONOMIC DEVELOPMENT CORPORATION
AMENDED AND RESTATED BYLAWS
(See Attached)
SEDC RESOLUTION NO. 2023-3
A RESOLUTION BY THE CITY OF SCHERTZ ECONOMIC DEVELOPMENT
CORPORATION, APPROVING AMENDED AND RESTATED BYLAWS OF SUCH
CORPORATION; AND OTHER MATTERS IN CONNECTION THEREWITH
WHEREAS, the City Council (the "Council") of the City of Schertz, Texas (the "City")
has previously authorized the creation of the City of Schertz Economic Development
Corporation (the "Corporation") in accordance with the Development Corporation Act, as
amended, Title 12, Subtitle Cl, Texas Local Government Code (the "Act"); and
WHEREAS, on February 5, 2013, the Council reviewed and approved the existing
Certificate of Formation and Bylaws of the Corporation in Ordinance l 3-M-04; and
WHEREAS, the Council took action on May 10, 2022, approving Ordinance 22-M-20
changing the term end dates for the City of Schertz Economic Development Corporation; and;
WHEREAS, the Board of Directors of the Corporation desires to change the end dates of
the terms of the directors from May 31 to September 30 of the year in which the directors' term
expires, in order to be consistent with Ordinance 22-M-20; and
WHEREAS, the Board of Directors of the Corporation desires to alter the codes by which the
Corporation shall be governed and the requirements for an action to be taken by the Board; and
WHEREAS, the Board of Directors have reviewed and approved the proposed amendments
to the existing Bylaws of the Corporation and has determined to authorize and approve such
amendments; and
WHEREAS, the Board of Directors hereby finds and determines that the adoption of this
Resolution is in the best interests of the citizens of the City; now, therefore,
NOW, THEREFORE, BE IT RESOLVED BY THE BOARD OF DIRECTORS OF THE
CITY OF SCHERTZ ECONOMIC DEVELOPMENT COPROPARTION THAT:
Section 1. The Board of Directors hereby approves the amended Bylaws for the
Corporation in the form attached hereto as Exhibit A.
Section 2. The recitals contained in the preamble hereof are hereby found to be true, and
such recitals are hereby made a part of this Resolution for all purposes and are adopted as a part
of the judgment and findings of the Governing Body.
Section 3. All ordinances and resolutions, or parts thereof, which are in conflict or
inconsistent with any provision of this Resolution are hereby repealed to the extent of such
conflict, and the provisions of this Resolution shall be and remain controlling as to the matters
resolved herein.
Section 4. This Resolution shall be construed and enforced in accordance with the laws of
the State of Texas and the United States of America.
Section 5. If any provision of this Resolution or the application thereof to any person or
circumstance shall be held to be invalid, the remainder of this Resolution and the application of
such provision to other persons and circumstances shall nevertheless be valid, and the Board
hereby declares that this Resolution would have been enacted without such invalid provision.
Section 6. It is officially found, determined, and declared that the meeting at which this
Resolution is adopted was open to the public and public notice of the time, place, and subject
matter of the public business to be considered at such meeting, including this Resolution, was
given, all as required by Chapter 551, as amended, Texas Government Code.
Section 7. This Resolution shall be in force and effect from and after its final passage,
and it is so ordered.
PASSED AND ADOPTED, this 23rd day of February 2023.
CITY OF SCHERTZ ECONOMIC
DEVELOPMENT C ORATION
Paul
EXH IB IT A
AMENDED AND RESTATED BYLAWS
(See Attached)
AMENDED AND RESTATED BYLAWS
OF
CITY OF SCHERTZ ECONOMIC DEVELOPMENT CORPORATION
ARTICLE I
PURPOSE AND POWERS
Section I.I. Purpose. The Corporation is incorporated for the purposes set forth in
Article Four of its Certificate of Formation, as amended (the "Certificate of Fomlation"), the
same to be accomplished on behalf of the City of Schertz, Texas (the "City") as its duly
constituted authority and instrumentality in accordance with the Development Corporation Act,
as amended (Title 12, Subtitle Cl, Texas Local Government Code) (the "Act"'), and other
applicable laws.
Section 1.2. Powers. In the fulfillment of its corporate purposes, the Corporation shall
be governed by Texas LGC Chapter 501, Chapter 502, and Chapter 505 of the Act and Chapter
22 of the Texas Business Organizations Code, and an election held in the City on August 9, 1997
(the "Election"), and shall have all the powers set forth and conferred in its Certificate of
Formation, in the Act, and in other applicable law, subject to the limitations prescribed therein
and herein and to the provisions thereof and hereof.
ARTICLE II
BOARD OF DIRECTORS
Section 2.1. Powers, Number and Term of Office.
(a) The property and affairs of the Corporation shall be managed and
controlled by a Board of Directors (the "Board ") under the guidance and direction of the City
Council of the City (the "Council ") and, subj ect to the restrictions imposed by law, by the
Certificate of Fom1ation and by these Amended and Restated Bylaws (these "Bylaws"), the
Board shall exercise all of the powers of the Corporation.
(b) The Board shall consist of seven (7) directors, each of whom shall be
appointed by the Council.
( c) Directors serve a two-year term beginning on October 1 st and ending on
September 30th, two years after appointment, or until a successor is appointed . Successor
directors shall have the qualifications, shall be of the classes of directors , and shall be appointed
to the terms set forth in the Certificate of Formation.
( d) Any director may be removed from office by the Council at will.
Section 2.2. Meetings of Directors. (a) The directors may hold their meetings at such
place or places in the City as the Board may from time to time determine; provided, however, in
the absence of any such determination by the Board, the meetings shall be held at the principal
office of the Corporation as specified in Section 5.1 of these Bylaws. R eg ular meetings of the
Board shall be he ld without the nece ssity of notice to directors at s uch times and places as shall
50429380.1 - 1 -
be designated from time to time by the Board. Special meetings of the Board shall be held
whenever called by the president, by a majority of the directors, by the Mayor of the City, or by a
majority of the Council.
(b) The secretary shall give notice to each director of each special meeting in
person or my mail, telephone or telegraph, at least two (2) hours before the meeting. Unless
otherwise indicated in the notice thereof, any and a11 matters pertaining to the purposes of the
Corporation may be considered and acted upon at a special meeting. At any meeting at which
every director shall be present, even though without any notice, any matter pertaining to the
purpose of the Corporation may be considered and acted upon consistent with applicable law.
( c) Whenever any notice is required to be given to the Board, such notice
shall be deemed to be sufficient if given by depositing the same in a post office box in a sealed
postpaid wrapper addressed to the person entitled thereto at his or her post office address as it
appears on the books of the Corporation, and such notice shall be deemed to have been given on
the day of such mailing. Attendance of a director at a meeting shall constitute a waiver of notice
of such meeting, except attendance of a director at a meeting for the express purpose of objecting
to the transaction of any business on the grounds that the meeting is not lawfully called or
convened. Neither the business to be transacted at nor the purpose of any regular or special
meeting of the Board need be specified in the notice to directors or waiver of notice of such
meeting, unless required by the Board. A waiver of notice in writing, signed by the person or
persons entitled to said notice, whether before or after the time stated therein, shall be deemed
equivalent to the giving of such notice.
Section 2.3. Open Meetings Act. All meetings and deliberations of the Board shall be
called, convened, held, and conducted, and notice shall be given to the public, in accordance with
the Texas Open Meetings Act, as amended (Chapter 551 , Texas Government Code) (the "Open
Meetings Act").
Section 2.4. Quorum. A majority of the entire membership of the Board shall
constitute a quorum to conduct official business of the Corporation. The act of a majority of the
Board of Directors present at a meeting at which a quorum is in attendance shall constitute the
act of the Board and of the Corporation, unless the act of a greater number is required by law. An
action that may be taken at a meeting of the Board of Directors, including an action required by
the Act to be taken at a meeting, may be taken without a meeting if each director signs a written
consent providing the action to be taken. The consent has the same effect as a unanimous vote
and may be stated as such in a document filed with the Secretary of State.
Section 2 .5. Conduct of Business.
(a) At the meetings of the Board, matters pertaining to the business of the
Corporation shall be considered in accordance with rules of procedure as from time to time
prescribed by the Board.
(b) The president shall preside at all meetings of the Board. In the absence of
the president, the vice president shall preside.
50429380.1 -2-
(c) The president shall be a voting member of the Board.
( d) The secretary of the Corporation shall act as secretary of all meetings of
the Board, but in the absence of the secretary, the presiding officer may appoint any person to act
as secretary of the meeting. The treasurer and any assistant secretary may, at the option of the
Board, be employees of the City and each member of the Board with the exception of the
president, vice president, or secretary, may be appointed as assistant secretaries; provided,
however, that to the extent the treasurer or any assistant secretary is an employee of the City such
person shall not be a member of the Board.
Section 2.6. Committees of the Board. The Board may designate two (2) or more
directors · or other persons to constitute a committee (including an advisory committee) of the
Board to exercise such authority, as approved by resolution of the Board; provided, however,
that all final, official actions of the Corporation may be exercised only by the Board. Each
committee so designated shal1 keep regular minutes of the transactions of its meetings and shall
cause such minutes to be recorded in books kept for that purpose in the principal office of the
Corporation and any such meetings must be conducted in accordance with the provisions of the
Open Meetings Act, if applicable.
Section 2. 7. Compensation of Directors. Directors shall not receive any salary or
compensation for their services as directors. However, they shall be reimbursed for their actual
expenses incurred in the performance of their official duties as directors.
ARTICLE III
OFFICERS
Section 3.1. Titles and Terms of Office.
(a) The officers of the Corporation shal1 be a president, a vice president, a
secretary, and a treasurer, and such other officers as the Board may from time to time elect to fill
a vacancy or as appointed by the Council. One person may hold more than one office, except
that the president shall not hold the office of secretary. Initial officers shall serve for the terms
disclosed in the Certificate of Formation. Thereafter, terms of office shall be for two (2) years
with the term of office expiring on September 30th of each year. Upon the expiration of the
terms, each officer shall have the right to be reappointed or reelected.
(b) All officers sha11 be subject to removal from office at any time by a vote
of a majority of the Council.
( c) A vacancy in the office of any director shall be filled by a vote of a
majority of the Council. The remaining directors may recommend to the Council a person to be
named to fill any such vacancy.
Section 3.2. Powers and Duties of the President. The president sha11 be the chief
operating executive officer of the Corporation, and, subject to the authority of the Board, the
president shall be in general charge of the properties and affairs of the Corporation and execute
all contracts, conveyances, franchises, bonds, deeds, assignments, mortgages, notes, and other
50429380.1 -3 -
instruments in the name of the Corporation. The president shall preside over the meetings of the
Corporation.
Section 3.3. Vice President. The vice president shall have such powers and duties as
may be prescribed by the Board and shall exercise the powers of the president during that
officer's absence or inability to act. Any action taken by the vice president in the perfonnance of
the duties of the president shall be conclusive evidence of the absence or inability to act of the
president at the time such action was taken.
Section 3.4. Treasurer. The treasurer shall be the chief fiscal officer of the
Corporation, and shall have the responsibility to see to the handling, custody, and security of all
funds and securities of the Corporation in accordance with these Bylaws. When necessary or
proper, the treasurer may endorse and sign, on behalf of the Corporation, for collection or
issuance, checks, notes, and other obligations in or drawn upon such bank, banks, or depositories
as shall be designated by the Board consistent with these Bylaws. The treasurer shall see to the
entry in the books of the Corporation full and accurate accounts of all money received and paid
out on account of the Corporation. The treasurer shall , at the expense of the Corporation, give
such bond for the faithful discharge of his/her duties in such form, and amount as the Board or
the Council may require. All check writing authority will follow all applicable City policies
concerning authorizations, signatures and disbursements.
Section 3.5. Secretarv. The secretary shall keep the minutes of all meetings of the
Board and books provided for that purpose, shall give and serve all notices , may sign with the
president in the name of the Corporation, and/or attest the signature thereto, all contracts,
conveyances, franchises , bonds, deeds, assignments, mortgages, notes , and other instruments of
the Corporation, shall have charge of the corporate books , records, documents , and instruments ,
except the books of account and financial records and securities, and such other books and
papers as the Board may direct, all of which shall at all reasonable times be open to public
inspection upon application at the principal office of the Corporation during business hours , and
shall in general perforn1 all duties incident to the office of secretary subject to the control of the
Board.
Section 3.6 . Executive Director. The City Manager, or his de signee, will serve as the
E xecutive Director of the Corporation to provide administrative support services for the
Corporation and shall perform duties as prescribed by the Board and Council. The Executive
Director shall not be a member of the Board .
Section 3. 7. General. The president, vice president, and the secretary shall be named
from among the members of the Board. The treasurer and any assistant secretary may, at the
option of the Board, be employees of the City. To the extent that the treasurer or any assi stant
secretary are employees of the City they shall not be members of the Board. The Executive
Director shall retain legal counsel and financial advisors for the Corporation, subject to the
approval of the majority of the Board.
Section 3 .8. Com pensation. Officers who are members of the Board shall not receive
any salary or compensation for their services, except that they shall be reimbursed for the actual
expenses incurred in t he p erformanc e o f their officia l duties as offic ers .
50429380 .1 - 4 -
ARTICLE IV
FUNCTIONAL CORPORA TE DUTIES AND REQUIREMENTS
Section 4.1. Ci ty of Schertz Economic Development Corporation Plan.
(a) It shall be the duty and obligation of the Board to finance and implement
the City of Schertz Economic Development Corporation Plan subject to approval or disapproval
by Council.
(b) In carrying out its obligations under subsection (a), the Corporation shall
be authorized to exercise all rights and powers granted under the Act, including, but not limited
to Chapter 501, Chapter 502, and Chapter 505 of the Act.
( c) The Board shall at least annually submit reports to the Council as to the
status of its activities in carrying out its obligations under this Section.
( d) Any and all agreements between the Corporation and other parties shall be
authorized, executed, and approved, and delivered in accordance with applicable law.
Section 4.2. Annual Corporate Budget. Prior to the commencement of each fiscal year
of the Corporation, the Board shall adopt a proposed budget of expected revenues from sources
set out in Section 4.5 of this Article and proposed expenditures for the next ensuing fiscal year.
The budget shall contain such classifications and shall be in such form as may be prescribed
from time to time by the Council. The budget shall not be effective until the same has been
approved by the Council.
Section 4.3. Books. Records . Audits.
(a) The Corporation shall keep and properly maintain in accordance with
generally accepting accounting principles, complete books, records, accounts, and financial
statements pertaining to its corporate funds, activities, and affairs.
(b) At the direction of the Council, the books, records, accounts, and financial
statements of the Corporation may be maintained for the Corporation by the accountants, staff
and personnel of the City.
(c) The Corporation, or the City if the option of subsection (b) is selected,
shall cause its books, records, accounts, and financial statements to be studied at least once each
fiscal year by an outside, independent auditing and accounting firm selected by Council and
approved by the Board. Such an audit shall be at the expense of the Corporation.
Section 4.4. Deposit and Investment of Corporation Funds.
(a) All proceeds from loans or from the issuance of bonds, notes, or other debt
instruments ("Obligations ") issued by the Corporation shall be deposited and invested as
provided in the resolution , order, indenture, or other documents authorizing or relating to their
execution or issuance.
50429380 . l - 5 -
(b) Subject to the requirements of contracts, Joan agreements, indentures, or
other agreements securing Obligations, all other money of the Corporation, if any, shall be
deposited, secured, and/or invested in the manner provided for the deposit, security, and/or
investment of the public funds of the City. The Board, with Council approval, shall designate
the accounts and depositories to be created and designated for such purposes, and the methods of
withdrawal of funds therefrom for use by and for the purposes of the Corporation upon the
signature of its treasurer and such other persons as the Board designates. The accounts,
reconciliation, and investment of such funds and accounts shall be performed by the City
Manager of the City, or his designee.
Section 4.5. Expenditure of Corporate Mone y. The sales and use taxes collected
pursuant to Chapter 501, Chapter 502, and Chapter 505 of the Act and the proceeds from the
investment of funds of the Corporation, the proceeds from the sale of property, revenues
generated by any Projects as defined in Chapter 501 , Chapter 502, and Chapter 505 of the Act
and payable to the Corporation or any other source of revenues that are payable to the
Corporation, and the proceeds derived from the sale of Obligations, may be expended by the
Corporation for any of the purposes authorized by the Act, the Certificate of Formation, the
City's Home Rule Charter, and the Election, subject to the following limitations:
Expenditures that may be made from a fund created with the proceeds of Obligations , and
expenditures of money derived from sources other than the proceeds of Obligations may be used
for the purpose of financing or otherwise providing one or more Projects, as defined in Chapter
501, Chapter 502, and Chapter 505 of the Act and in accordance with the Election;
All other proposed expenditures shall be made in accordance with and shall be set forth
in the annual budget required by Section 4.2 or in contracts meeting the requirements of
Section 4.l(d) of this Article.
Section 4.6. Issuance of Obli gations. No Obligations, including refunding obligations,
shall be authorized or sold and delivered by the Corporation unless the Council approves such
Obligations by action taken prior to the date of initial delivery of the Obligations to the initial
purchasers thereof.
ARTICLEV
MISCELLANEOUS PROVISIONS
Section 5.1 . Princi pal Office .
(a) The principal office and the registered office of the Corporation shall be
the registered office of the Corporation specified in the Certificate of Formation.
(b) The Corporation shall have and shall continually designate a registered
agent at its office, as required by the Act.
Section 5.2. Fiscal Year. The fiscal year of the Corporation shall be the same as the
fiscal year of the City.
50429380.1 - 6 -
Section 5.3. Seal. The seal, if any, of the Corporation shall be determined by the
Board.
Section 5.4. Resi gnations. Any director or officer may resign at any time. Such
resignation shall be made in writing and shall take effect at the time specified therein, or, if no
time is specified, at the time of its receipt by the president or secretary. The acceptance of
resignation shall not be necessary to make it effective, unless expressly so provided in the
resignation.
Section 5.5. A pproval or Advice and Consent of the Council. To the extent that these
Bylaws refer to any approval by the City or refer to advice and consent by the Council, such
advice and consent shall be evidenced by a certified copy of a resolution, ordinance, or motion
duly adopted by the Council.
Section 5.6. Services of City Staff and Officers. To the extent possible, the
Corporation shall utilize the services and the staff employees of the City. All requests for staff
time or inquiries of staff will be requested through the City Manager's Office.
Section 5. 7. Indemnification of Directors. Officers and Employees.
(a) As provided in the Act, the Corporation is, for the purposes of the Texas
Tort Claims Act, as amended (Subchapter A, Chapter 10 I, Texas Civil Practices and Remedies
Code), a governmental unit and its actions are governmental functions.
(b) The Corporation shall indemnify each and every member of the Board, its
officers and its employees and each member of the Council and each employee of the City, to the
fullest extent permitted by law, against any and all liability or expense, including attorneys fees ,
incurred by any of such persons by reason of any actions or omissions that may arise out of the
sanctions and activities of the Corporation. The legal counsel for the Corporation is authorized
to provide a defense for members of the Board, officers, and employees of the Corporation.
ARTICLE VI
EFFECTIVE DA TE, AMENDMENTS
Section 6.1. Effective Date. These Bylaws shall become effective upon the approval of
these Bylaws by the Council.
Section 6.2. Amendments to Certificate of Formation and Bylaws. The Certificate of
Formation of the Corporation and these Bylaws may be amended only in the manner provided in
the Certificate of Formation and the Act.
* * *
Adopted: February 23, 2023
50429380.1 - 7 -
50429380.1 - 1 -
AMENDED AND RESTATED BYLAWS
OF
CITY OF SCHERTZ ECONOMIC DEVELOPMENT CORPORATION
ARTICLE I
PURPOSE AND POWERS
Section 1.1. Purpose. The Corporation is incorporated for the purposes set forth in
Article Four of its Certificate of Formation, as amended (the “Certificate of Formation”), the
same to be accomplished on behalf of the City of Schertz, Texas (the “City”) as its duly
constituted authority and instrumentality in accordance with the Development Corporation Act,
as amended (Title 12, Subtitle C1, Texas Local Government Code) (the “Act”), and other
applicable laws.
Section 1.2. Powers. In the fulfillment of its corporate purposes, the Corporation shall
be governed by Texas LGC Chapter 501, Chapter 502, and Chapter 505 of the Act and Chapter
22 of the Texas Business Organizations Code, and an election held in the City on August 9, 1997
(the “Election”), and shall have all the powers set forth and conferred in its Certificate of
Formation, in the Act, and in other applicable law, subject to the limitations prescribed therein
and herein and to the provisions thereof and hereof.
ARTICLE II
BOARD OF DIRECTORS
Section 2.1. Powers, Number and Term of Office.
(a) The property and affairs of the Corporation shall be managed and
controlled by a Board of Directors (the “Board”) under the guidance and direction of the City
Council of the City (the “Council”) and, subject to the restrictions imposed by law, by the
Certificate of Formation and by these Amended and Restated Bylaws (these “Bylaws”), the
Board shall exercise all of the powers of the Corporation.
(b) The Board shall consist of seven (7) directors, each of whom shall be
appointed by the Council.
(c) The directors constituting the Board shall be those directors named in the
Certificate of Formation, as amended and restated on February 5, 2013Directors serve a two-year
term beginning on October 1st and ending on September 30th, two years after appointment, or
until a successor is appointed. Successor directors shall have the qualifications, shall be of the
classes of directors, and shall be appointed to the terms set forth in the Certificate of Formation.
(d) Any director may be removed from office by the Council at will.
Section 2.2. Meetings of Directors. (a) The directors may hold their meetings at such
place or places in the City as the Board may from time to time determine; provided, however, in
the absence of any such determination by the Board, the meetings shall be held at the principal
office of the Corporation as specified in Section 5.1 of these Bylaws. Regular meetings of the
50429380.1 - 2 -
Board shall be held without the necessity of notice to directors at such times and places as shall
be designated from time to time by the Board. Special meetings of the Board shall be held
whenever called by the president, by a majority of the directors, by the Mayor of the City, or by a
majority of the Council.
(b) The secretary shall give notice to each director of each special meeting in
person or my mail, telephone or telegraph, at least two (2) hours before the meeting. Unless
otherwise indicated in the notice thereof, any and all matters pertaining to the purposes of the
Corporation may be considered and acted upon at a special meeting. At any meeting at which
every director shall be present, even though without any notice, any matter pertaining to the
purpose of the Corporation may be considered and acted upon consistent with applicable law.
(c) Whenever any notice is required to be given to the Board, such notice
shall be deemed to be sufficient if given by depositing the same in a post office box in a sealed
postpaid wrapper addressed to the person entitled thereto at his or her post office address as it
appears on the books of the Corporation, and such notice shall be deemed to have been given on
the day of such mailing. Attendance of a director at a meeting shall constitute a waiver of notice
of such meeting, except attendance of a director at a meeting for the express purpose of objecting
to the transaction of any business on the grounds that the meeting is not lawfully called or
convened. Neither the business to be transacted at nor the purpose of any regular or special
meeting of the Board need be specified in the notice to directors or waiver of notice of such
meeting, unless required by the Board. A waiver of notice in writing, signed by the person or
persons entitled to said notice, whether before or after the time stated therein, shall be deemed
equivalent to the giving of such notice.
Section 2.3. Open Meetings Act. All meetings and deliberations of the Board shall be
called, convened, held, and conducted, and notice shall be given to the public, in accordance with
the Texas Open Meetings Act, as amended (Chapter 551, Texas Government Code) (the “Open
Meetings Act”).
Section 2.4. Quorum. A majority of the entire membership of the Board shall
constitute a quorum to conduct official business of the Corporation. The act of a majority of the
Board of Directors present at a meeting at which a quorum is in attendance shall constitute the
act of the Board and of the Corporation, unless the act of a greater number is required by law. An
action that may be taken at a meeting of the Board of Directors, including an action required by
the Act to be taken at a meeting, may be taken without a meeting if each director signs a written
consent providing the action to be taken. The consent has the same effect as a unanimous vote
and may be stated as such in a document filed with the secretary of state
Section 2.5. Conduct of Business.
(a) At the meetings of the Board, matters pertaining to the business of the
Corporation shall be considered in accordance with rules of procedure as from time to time
prescribed by the Board.
(b) The president shall preside at all meetings of the Board. In the absence of
the president, the vice president shall preside.
50429380.1 - 3 -
(c) The president shall be a voting member of the Board.
(d) The secretary of the Corporation shall act as secretary of all meetings of
the Board, but in the absence of the secretary, the presiding officer may appoint any person to act
as secretary of the meeting. The treasurer and any assistant secretary may, at the option of the
Board, be employees of the City and each member of the Board with the exception of the
president, vice president, or secretary, may be appointed as assistant secretaries; provided,
however, that to the extent the treasurer or any assistant secretary is an employee of the City such
person shall not be a member of the Board.
Section 2.6. Committees of the Board. The Board may designate two (2) or more
directors or other persons to constitute a committee (including an advisory committee) of the
Board to exercise such authority, as approved by resolution of the Board; provided, however,
that all final, official actions of the Corporation may be exercised only by the Board. Each
committee so designated shall keep regular minutes of the transactions of its meetings and shall
cause such minutes to be recorded in books kept for that purpose in the principal office of the
Corporation and any such meetings must be conducted in accordance with the provisions of the
Open Meetings Act, if applicable.
Section 2.7. Compensation of Directors. Directors shall not receive any salary or
compensation for their services as directors. However, they shall be reimbursed for their actual
expenses incurred in the performance of their official duties as directors.
ARTICLE III
OFFICERS
Section 3.1. Titles and Terms of Office.
(a) The officers of the Corporation shall be a president, a vice president, a
secretary, and a treasurer, and such other officers as the Board may from time to time elect to fill
a vacancy or as appointed by the Council. One person may hold more than one office, except
that the president shall not hold the office of secretary. Initial officers shall serve for the terms
disclosed in the Certificate of Formation. Thereafter, terms of office shall be for two (2) years
with the term of office expiring on May 31September 30th of each year. Upon the expiration of
the terms, each officer shall have the right to be reappointed or reelected.
(b) All officers shall be subject to removal from office at any time by a vote
of a majority of the Council.
(c) A vacancy in the office of any director shall be filled by a vote of a
majority of the Council. The remaining directors may recommend to the Council a person to be
named to fill any such vacancy.
Section 3.2. Powers and Duties of the President. The president shall be the chief
operating executive officer of the Corporation, and, subject to the authority of the Board, the
president shall be in general charge of the properties and affairs of the Corporation and execute
all contracts, conveyances, franchises, bonds, deeds, assignments, mortgages, notes, and other
50429380.1 - 4 -
instruments in the name of the Corporation. The president shall preside over the meetings of the
Corporation.
Section 3.3. Vice President. The vice president shall have such powers and duties as
may be prescribed by the Board and shall exercise the powers of the president during that
officer’s absence or inability to act. Any action taken by the vice president in the performance of
the duties of the president shall be conclusive evidence of the absence or inability to act of the
president at the time such action was taken.
Section 3.4. Treasurer. The treasurer shall be the chief fiscal officer of the
Corporation, and shall have the responsibility to see to the handling, custody, and security of all
funds and securities of the Corporation in accordance with these Bylaws. When necessary or
proper, the treasurer may endorse and sign, on behalf of the Corporation, for collection or
issuance, checks, notes, and other obligations in or drawn upon such bank, banks, or depositories
as shall be designated by the Board consistent with these Bylaws. The treasurer shall see to the
entry in the books of the Corporation full and accurate accounts of all money received and paid
out on account of the Corporation. The treasurer shall, at the expense of the Corporation, give
such bond for the faithful discharge of his/her duties in such form, and amount as the Board or
the Council may require. All check writing authority will follow all applicable City policies
concerning authorizations, signatures and disbursements.
Section 3.5. Secretary. The secretary shall keep the minutes of all meetings of the
Board and books provided for that purpose, shall give and serve all notices, may sign with the
president in the name of the Corporation, and/or attest the signature thereto, all contracts,
conveyances, franchises, bonds, deeds, assignments, mortgages, notes, and other instruments of
the Corporation, shall have charge of the corporate books, records, documents, and instruments,
except the books of account and financial records and securities, and such other books and
papers as the Board may direct, all of which shall at all reasonable times be open to public
inspection upon application at the principal office of the Corporation during business hours, and
shall in general perform all duties incident to the office of secretary subject to the control of the
Board.
Section 3.6. Executive Director. The City Manager, or his designee, will serve as the
Executive Director of the Corporation to provide administrative support services for the
Corporation and shall perform duties as prescribed by the Board and Council. The Executive
Director shall not be a member of the Board.
Section 3.7. General. The president, vice president, and the secretary shall be named
from among the members of the Board. The treasurer and any assistant secretary may, at the
option of the Board, be employees of the City. To the extent that the treasurer or any assistant
secretary are employees of the City they shall not be members of the Board. The Executive
Director shall retain legal counsel and financial advisors for the Corporation, subject to the
approval of the majority of the Board.
Section 3.8. Compensation. Officers who are members of the Board shall not receive
any salary or compensation for their services, except that they shall be reimbursed for the actual
expenses incurred in the performance of their official duties as officers.
50429380.1 - 5 -
ARTICLE IV
FUNCTIONAL CORPORATE DUTIES AND REQUIREMENTS
Section 4.1. City of Schertz Economic Development Corporation Plan.
(a) It shall be the duty and obligation of the Board to finance and implement
the City of Schertz Economic Development Corporation Plan subject to approval or disapproval
by Council.
(b) In carrying out its obligations under subsection (a), the Corporation shall
be authorized to exercise all rights and powers granted under the Act, including, but not limited
to Chapter 501, Chapter 502, and Chapter 505 of the Act.
(c) The Board shall at least annually submit reports to the Council as to the
status of its activities in carrying out its obligations under this Section.
(d) Any and all agreements between the Corporation and other parties shall be
authorized, executed, and approved, and delivered in accordance with applicable law.
Section 4.2. Annual Corporate Budget. Prior to the commencement of each fiscal year
of the Corporation, the Board shall adopt a proposed budget of expected revenues from sources
set out in Section 4.5 of this Article and proposed expenditures for the next ensuing fiscal year.
The budget shall contain such classifications and shall be in such form as may be prescribed
from time to time by the Council. The budget shall not be effective until the same has been
approved by the Council.
Section 4.3. Books, Records, Audits.
(a) The Corporation shall keep and properly maintain in accordance with
generally accepting accounting principles, complete books, records, accounts, and financial
statements pertaining to its corporate funds, activities, and affairs.
(b) At the direction of the Council, the books, records, accounts, and financial
statements of the Corporation may be maintained for the Corporation by the accountants, staff
and personnel of the City.
(c) The Corporation, or the City if the option of subsection (b) is selected,
shall cause its books, records, accounts, and financial statements to be studied at least once each
fiscal year by an outside, independent auditing and accounting firm selected by Council and
approved by the Board. Such an audit shall be at the expense of the Corporation.
Section 4.4. Deposit and Investment of Corporation Funds.
(a) All proceeds from loans or from the issuance of bonds, notes, or other debt
instruments (“Obligations”) issued by the Corporation shall be deposited and invested as
provided in the resolution, order, indenture, or other documents authorizing or relating to their
execution or issuance.
50429380.1 - 6 -
(b) Subject to the requirements of contracts, loan agreements, indentures, or
other agreements securing Obligations, all other money of the Corporation, if any, shall be
deposited, secured, and/or invested in the manner provided for the deposit, security, and/or
investment of the public funds of the City. The Board, with Council approval, shall designate
the accounts and depositories to be created and designated for such purposes, and the methods of
withdrawal of funds therefrom for use by and for the purposes of the Corporation upon the
signature of its treasurer and such other persons as the Board designates. The accounts,
reconciliation, and investment of such funds and accounts shall be performed by the City
Manager of the City, or his designee.
Section 4.5. Expenditure of Corporate Money. The sales and use taxes collected
pursuant to Chapter 501, Chapter 502, and Chapter 505 of the Act and the proceeds from the
investment of funds of the Corporation, the proceeds from the sale of property, revenues
generated by any Projects as defined in Chapter 501, Chapter 502, and Chapter 505 of the Act
and payable to the Corporation or any other source of revenues that are payable to the
Corporation, and the proceeds derived from the sale of Obligations, may be expended by the
Corporation for any of the purposes authorized by the Act, the Certificate of Formation, the
City’s Home Rule Charter, and the Election, subject to the following limitations:
Expenditures that may be made from a fund created with the proceeds of Obligations, and
expenditures of money derived from sources other than the proceeds of Obligations may be used
for the purpose of financing or otherwise providing one or more Projects, as defined in Chapter
501, Chapter 502, and Chapter 505 of the Act and in accordance with the Election;
All other proposed expenditures shall be made in accordance with and shall be set forth
in the annual budget required by Section 4.2 or in contracts meeting the requirements of
Section 4.1(d) of this Article.
Section 4.6. Issuance of Obligations. No Obligations, including refunding obligations,
shall be authorized or sold and delivered by the Corporation unless the Council approves such
Obligations by action taken prior to the date of initial delivery of the Obligations to the initial
purchasers thereof.
ARTICLE V
MISCELLANEOUS PROVISIONS
Section 5.1. Principal Office.
(a) The principal office and the registered office of the Corporation shall be
the registered office of the Corporation specified in the Certificate of Formation.
(b) The Corporation shall have and shall continually designate a registered
agent at its office, as required by the Act.
Section 5.2. Fiscal Year. The fiscal year of the Corporation shall be the same as the
fiscal year of the City.
50429380.1 - 7 -
Section 5.3. Seal. The seal, if any, of the Corporation shall be determined by the
Board.
Section 5.4. Resignations. Any director or officer may resign at any time. Such
resignation shall be made in writing and shall take effect at the time specified therein, or, if no
time is specified, at the time of its receipt by the president or secretary. The acceptance of
resignation shall not be necessary to make it effective, unless expressly so provided in the
resignation.
Section 5.5. Approval or Advice and Consent of the Council. To the extent that these
Bylaws refer to any approval by the City or refer to advice and consent by the Council, such
advice and consent shall be evidenced by a certified copy of a resolution, ordinance, or motion
duly adopted by the Council.
Section 5.6. Services of City Staff and Officers. To the extent possible, the
Corporation shall utilize the services and the staff employees of the City. All requests for staff
time or inquiries of staff will be requested through the City Manager’s Office.
Section 5.7. Indemnification of Directors, Officers and Employees.
(a) As provided in the Act, the Corporation is, for the purposes of the Texas
Tort Claims Act, as amended (Subchapter A, Chapter 101, Texas Civil Practices and Remedies
Code), a governmental unit and its actions are governmental functions.
(b) The Corporation shall indemnify each and every member of the Board, its
officers and its employees and each member of the Council and each employee of the City, to the
fullest extent permitted by law, against any and all liability or expense, including attorneys fees,
incurred by any of such persons by reason of any actions or omissions that may arise out of the
sanctions and activities of the Corporation. The legal counsel for the Corporation is authorized
to provide a defense for members of the Board, officers, and employees of the Corporation.
ARTICLE VI
EFFECTIVE DATE, AMENDMENTS
Section 6.1. Effective Date. These Bylaws shall become effective upon the approval of
these Bylaws by the Council.
Section 6.2. Amendments to Certificate of Formation and Bylaws. The Certificate of
Formation of the Corporation and these Bylaws may be amended only in the manner provided in
the Certificate of Formation and the Act.
* * *
Adopted: February 5, 201323, 2023
Agenda No. 5.
CITY COUNCIL MEMORANDUM
City Council
Meeting:March 14, 2023
Department:Engineering
Subject:Resolution 23-R-24 - Consideration and/or action by the City Council of the City
of Schertz, Texas, authorizing the City Manager to enter into Standard Utility
Agreement with the State of Texas for the relocation of utilities – specifically the
Riata Lift Station – along IH 35 in preparation for the IH 35 NEX Project.
(B.James/K.Woodlee/E.Schulze)
BACKGROUND
Due to conflicts with the Texas Department of Transportation’s (TxDOT) proposed IH35 NEX
Northbound Frontage Road project, the City of Schertz must relocate the existing Riata Lift Station and
associated sewer mains. The relocated improvements will be shifted approximately 60 feet away from
the existing frontage road and will be located within a new site for the lift station and easement for the
gravity and force mains leading to and from the lift station from Fairlawn Avenue.
As is typical with utility relocations along interstate facilities necessitated by TxDOT improvements,
the work is fully reimbursable. Responsibilities of the City and TxDOT related to this relocation are
outlined in a Standard Utility Agreement (SUA) funding reimbursement. Project expenses include the
following.
Professional Services $143,000
Property Acquisition $275,000 (estimated)
Construction $2,400,000 (estimated)
Total (reimbursable)$2,818,000 (estimated)
GOAL
The goal of Resolution 23-R-24 is to authorize a SUA with the State of Texas for the relocation of
utilities due to TXDOT’s I35 NEX project.
COMMUNITY BENEFIT
The relocation of utilities will allow for the continuation of sewer service to residents and businesses
along the IH 35 corridor.
SUMMARY OF RECOMMENDED ACTION
It is recommended that Council approves Resolution 23-R-24.
FISCAL IMPACT
Initial funding for the design work has been allocated from the City’s Water and Sewer Construction
Reserves. Advance funding for the easement acquisition and construction of the utility relocations will
be from Water and Sewer Construction Reserves. The total project is expected to cost $2.8 million. All
project costs are reimbursable from the State of Texas due to this being an interstate highway.
RECOMMENDATION
Staff recommends that City Council approve Resolution 23-R-24, authorizing a SUA with the State of
Texas for the relocation of utilities along Interstate Highway 35.
Attachments
Standard Utility Agreement
Res 23 R 24
Form ROW-U-35
(Rev.10/20)
Page 1
______ __________ ______ __________
Initial Date Initial Date
TxDOT Utility
STANDARD UTILITY AGREEMENT
U Number: N/A Utility ID: U00014203
District: San Antonio County: Comal
Federal Project No.: NH 1702(809) Highway: IH 35
ROW CSJ: 0016-05-116 From: Guadalupe/Comal County Line
Highway Project Letting Date: 9/1/2026
To: FM 1103
This Agreement by and between the State of Texas, acting by and through the Texas Transportation Commission,
(“State”), and City of Schertz, (“Utility”), acting by and through its duly authorized representative, shall be effective
on the date of approval and execution by and on behalf of the State.
WHEREAS, the State has deemed it necessary to make certain highway improvements as designated by the State
and approved by the Federal Highway Administration within the limits of the highway as indicated above (the
“Highway Project”);
WHEREAS, the proposed Highway Project will necessitate the adjustment, removal, and/or relocation of certain
facilities of the Utility as indicated in the following statement of work: Due to conflicts with the proposed I35 NEX
Northbound Frontage Road paving, grading, and drainage improvements between centerline Sta. 1101+00 and
Sta. 1105+00, the City of Schertz proposes to abandon their existing Riata Lift Station, portions of their existing 8-
Inch Gravity Sewer Main, and portions of their existing 6-Inch Sewer Forcemain that are within the proposed TxDOT
Right-of-Way. The existing City of Schertz utility infrastructure is currently located outside of the existing TxDOT
Right-of-Way, within City of Schertz easement. The existing longitudinal utility improvements, the gravity sewer
main and force main, total approximately 745 linear feet in length. The City of Schertz proposes to replace the
existing lift station, gravity sewer main, and force main to be located outside of the proposed TxDOT Right-of-Way,
within City of Schertz easement aquired for this project; and more specifically as shown in the Utility’s plans,
specifications and estimated costs, which are attached hereto as Attachment “A”.
WHEREAS, the State will participate in the costs of the adjustment, removal, and relocation of certain facilities to
the extent as may be eligible for State and/or Federal participation.
WHEREAS, the State, upon receipt of evidence it deems sufficient, acknowledges the Utility’s interest in certain
lands and facilities that entitle it to reimbursement for the adjustment, removal, and relocation of certain of its
facilities located upon the lands as indicated in the statement of work above.
NOW, THEREFORE, BE IT AGREED:
The State will pay to the Utility the costs incurred in adjustment, removal, and relocation of the Utility’s facilities
up to the amount said costs may be eligible for State participation.
All conduct under this agreement, including but not limited to the adjustment, removal, and relocation of the facility,
the development and reimbursement of costs, any environmental requirements, and retention of records will be in
accordance with all applicable federal and state laws, rules and regulations, including, without limitation, the Federal
Uniform Relocation Assistance and Real Property Acquisition Policies Act, 42 U.S.C. §§ 4601, et seq., the National
Environmental Policy Act, 42 U.S.C. §§ 4321, et seq., the Buy America provisions of 23 U.S.C. § 313 and 23 CFR
635.410, as amended, Texas Transportation Code § 223.045, the Utility Relocations, Adjustments, and
Reimbursements provisions of 23 CFR 645, Subpart A, and the Utility Accommodation provisions of 23 CFR 645,
Subpart B.
Form ROW-U-35
(Rev. 10/20)
Page 2
______ __________ ______ __________
Initial Date Initial Date
TxDOT Utility
The Utility shall supply, upon request by the State, proof of compliance with the aforementioned laws, rules,
regulations, and guidelines prior to the commencement of the adjustment, removal, and relocation of the facility.
The Utility shall not commence any physical work, including without limitation site preparation, on the State’s right
of way or future right of way, until TxDOT provides the Utility with written authorization to proceed with the physical
work upon TxDOT’s completion and clearance of its environmental review of the Highway Project. Any such work
by the Utility prior to TxDOT’s written authorization to proceed will not be eligible for reimbursement and the Utility
is responsible for entering any property within the proposed limits of the Highway Project that has not yet been
acquired by TxDOT. This written authorization to proceed with the physical work is in addition to the authorization
to commence work outlined below. Notwithstanding the foregoing, the provisions of this paragraph are required
only when TxDOT has not obtained completion and clearance of its environmental review of the Highway Project
prior to the execution of this Agreement by the State and the Utility.
The Utility shall comply with the Buy America provisions of 23 U.S.C. § 313, 23 CFR 635.410, as amended, and
the Steel and Iron Preference provisions of Texas Transportation Code § 223.045 and, when products that are
composed predominately of steel and/or iron are incorporated into the permanent installation of the utility facility,
use domestically manufactured products. TxDOT Form 1818 (Material Statement), along with all required
attachments, must be submitted, prior to the commencement of the adjustment, removal, and relocation of the
facility, as evidence of compliance with the aforementioned provisions. Failure to submit the required documentation
or to comply with the Buy America, and Steel and Iron Preference requirements shall result in: (1) the Utility
becoming ineligible to receive any contract or subcontract made with funds authorized under the Intermodal Surface
Transportation Efficiency Act of 1991; (2) the State withholding reimbursement for the costs incurred by the Utility
in the adjustment, removal, and relocation of the Utility’s facilities; and (3) removal and replacement of the non-
compliant products.
The Utility agrees to develop relocation or adjustment costs by accumulating actual direct and related indirect costs
in accordance with a work order accounting procedure prescribed by the State, or may, with the State’s approval,
accumulate actual direct and related indirect costs in accordance with an established accounting procedure
developed by the Utility. Bills for work hereunder are to be submitted to the State not later than one (1) year after
completion of the work. Failure to submit the request for final payment, in addition to all supporting documentation,
within one (1) year after completion of the work may result in forfeiture of payment for said work.
When requested, the State will make intermediate payments at not less than monthly intervals to the Utility when
properly billed. Such payments will not exceed 90 percent (90%) of the eligible cost as shown in each such billing.
Intermediate payments shall not be construed as final payment for any items included in the intermediate payment.
The State will, upon satisfactory completion of the adjustment, removal, and/or relocation and upon receipt of final
billing prepared in an approved form and manner and accounting for any intermediate payments, make payment in
the amount of 90 percent (90%) of the eligible costs as shown in the final billing prior to audit and after such audit
shall make an additional final payment totaling the reimbursement amount found eligible for State reimbursement.
Alternatively, the State agrees to pay the Utility an agreed lump sum of $ as supported by the attached
estimated costs. The State will, upon satisfactory completion of the adjustments, removals, and relocations and
upon receipt of a final billing, make payment to the Utility in the agreed amount.
Upon execution of this agreement by both parties hereto, the State will, by written notice, authorize the Utility to
perform such work diligently and to conclude said adjustment, removal, and relocation by the stated completion
date which is attached hereto in Attachment “C”. The completion date shall be extended for delays caused by
events outside the Utility’s control, including an event of Force Majeure, which shall include a strike, war or act of
war (whether an actual declaration of war is made or not), insurrection, riot, act of public enemy, accident, fire, flood
or other act of God, sabotage, or other events, interference by the State or any other party with the Utility’s ability
to proceed with the work, or any other event in which the Utility has exercised all due care in the prevention thereof
so that the causes of other events are beyond the control and without the fault or negligence of the Utility.
This agreement in its entirety consists of the following elements:
Form ROW-U-35
(Rev. 10/20)
Page 3
______ __________ ______ __________
Initial Date Initial Date
TxDOT Utility
Standard Utility Agreement – ROW-U-35;
• Plans, Specifications, and Estimated Costs (Attachment “A”);
• Accounting Method (Attachment “B”);
• Schedule of Work (Attachment “C”);
• Statement Covering Contract Work – ROW-U-48 (Attachment “D”);
• Utility Joint Use Agreement – ROW-U-JUA and/or Utility Installation Request – Form 1082 (Attachment
“E”);
• Eligibility Ratio (Attachment “F”);
• Betterment Calculation and Estimate (Attachment “G”); and
• Proof of Property Interest – ROW-U-Affidavit (Attachment “H”).
All attachments are included herein as if fully set forth. In the event it is determined that a substantial change from
the statement of work contained in this agreement is required, reimbursement therefore shall be limited to costs
covered by a modification or amendment of this agreement or a written change or extra work order approved by the
State and the Utility.
This agreement is subject to cancellation by the State at any time up to the date that work under this agreement
has been authorized, and such cancellation will not create any liability on the part of the State. However, the State
will review and reimburse the Utility for eligible costs incurred by the Utility in preparation of this Agreement.
The State Auditor may conduct an audit or investigation of any entity receiving funds from the State directly under
this contract or indirectly through a subcontract under this contract. Acceptance of funds directly under this contract
or indirectly through a subcontract under this contract acts as acceptance of the authority of the State Auditor, under
the direction of the Legislative Audit Committee, to conduct an audit or investigation in connection with those funds.
An entity that is the subject of an audit or investigation must provide the state auditor with access to any information
the state auditor considers relevant to the investigation or audit.
The Utility by execution of this agreement does not waive any of the rights that the Utility may have within the
limits of the law.
It is expressly understood that the Utility conducts the adjustment, removal, and relocation at its own risk, and that
the State makes no warranties or representations regarding the existence or location of utilities currently within its
right of way.
Form ROW-U-35
(Rev. 10/20)
Page 4
______ __________ ______ __________
Initial Date Initial Date
TxDOT Utility
The signatories to this agreement warrant that each has the authority to enter into this agreement on behalf of the
party represented.
UTILITY EXECUTION RECOMMENDED:
Utility: City of Schertz
Name of Utility Director of TP&D (or designee), District
By:
Authorized Signature
THE STATE OF TEXAS
Executed and approved for the Texas
Transportation Commission for the purpose
and effect of activating and/or carrying out the
orders, established policies or work programs
heretofore approved and authorized by the
Texas Transportation Commission.
Steve Williams, ICMA-CM, MPA, CGFO
Print or Type Name
Title: City Manager
Date:
By:
District Engineer (or designee)
Date:
Form ROW-U-35
(Rev. 10/20)
Page 5
______ __________ ______ __________
Initial Date Initial Date
TxDOT Utility
Attachment “A”
Plans, Specifications, and Estimated Costs
All material items within cost estimate that must meet Buy America or Steel and Iron
Preference Provision requirements must be indicated with an asterisk (*).
Currently, we do not have Buy America required materials planned for this project. In
the event that Buy America compliant materials are used during construction on this
project, compliance documentation will be provided.
There are non-domestic iron and steel materials in this project that fall under the De
Minimus equation. Calculation showing the total cost does not exceed one-tenth of one
percent (0.1 %) of the individual utility agreement amount or $2,500.00, whichever is
greater is required.
We understand the Buy America Compliance Requirements and will supply the required
documentation to TxDOT indicating compliance with this provision. The following
documents will be supplied prior to installation of the materials:
1) Form 1818 - Material Statement
2) Material Test Reports or Certifications
January 30, 2023
N.T.S.
LOCATION MAP
DAVID KNEUPER P.E.
LICENSE NO. 96676
JO
B
N
O
.
8
0
0
2
-
1
5
IH
-
3
5
R
I
A
T
A
L
I
F
T
S
T
A
T
I
O
N
R
E
L
O
C
A
T
I
O
N
A
N
D
OF
F
S
I
T
E
S
E
W
E
R
I
M
P
R
O
V
E
M
E
N
T
S
CONSTRUCTION PLANS FOR
PROJECT SITE
IH-35, SCHERTZ TX
IH-35 RIATA LIFT STATION RELOCATION
AND OFFSITE SEWER IMPROVEMENTS
100% REVIEW SET
FM 2623
GUAD
A
L
U
P
E
C
O
U
N
T
Y
IH-3
5
F
A
I
R
L
A
W
N
A
V
E
.
Sheet List Table
Sheet Number Sheet Title
COVER SHEET
CS-1 COVER SHEET
GENERAL NOTES
GN-1 GENERAL NOTES
GN-2 TCEQ GENERAL NOTES 1 OF 2
GN-3 TCEQ GENERAL NOTES 2 OF 2
DEMO SHEET
DM-1 DEMO SHEET 1 OF 2
DM-2 DEMO SHEET 2 OF 2
LIFT STATION DESIGN
LS-1 LIFT STATION SITE PLAN
LS-2 LIFT STATION GRADING, EROSION &
SEDIMENTATION CONTROL PLAN
LS-3 DIMENSION CONTROL SHEET
LS-4 OFF-SITE 8'' GRAVITY MAIN
LS-5 OFF-SITE 6'' FORCE MAIN
LS-6 LIFT STATION PLAN VIEW SHEET
LS-7 LIFT STATION PROFILE VIEW SHEET
LS-8 WET WELL AND PIPING DETAILS SHEET 1 OF 3
LS-9 WET WELL AND PIPING DETAILS SHEET 2 OF 3
LS-10 WET WELL AND PIPING DETAILS SHEET 3 OF 3
LS-11 FLATWORK DETAILS
LS-12 DETAILS 1 OF 3
LS-13 DETAILS 2 OF 3
LS-14 DETAILS 3 OF 3
STRUCTURAL SHEETS
S-1 WET WELL STRUCTURAL NOTES
S-2 WET WELL PLANS
S-3 WET WELL SECTION
ELECTRICAL SHEETS
E-01 ELECTRICAL ABBREVIATIONS, LEGENDS, AND
GENERAL NOTES
E-02 ELECTRICAL SITE PLAN - DEMOLITION
E-03 ELECTRICAL SITE PLAN - PROPOSED
E-04 ELECTRICAL ONE-LINE DIAGRAM
E-05 ELECTRICAL CONTROL AND SCHEMATICS
DIAGRAMS
E-06 ELECTRICAL SCHEMATIC DIAGRAM
E-07 ELECTRICAL SCHEDULES
E-08 GENERATOR DETAILS SHEET 1
E-09 GENERATOR DETAILS SHEET 2
E-10 ELECTRICAL DETAILS SHEET 1
E-11 ELECTRICAL DETAILS SHEET 2
E-12 ELECTRICAL DETAILS SHEET 3
E-13 ELECTRICAL DETAILS SHEET 4
JOB NO. 8032-03
SHEET CS-1 OF 36
NOTES:
1.ENGINEERING STAMPED APPROVED CIVIL SHEETS
MUST BE INCLUDED WHEN SENDING THE REVISED
CONSTRUCTION PLANS.
2.THE CONTRACTOR IS RESPONSIBLE FOR COMPLYING
WITH THE CITY OF SCHERTZ ADOPTED CODES AND
ORDINANCES EVEN IF NOT SPECIFICALLY
MENTIONED OR IDENTIFIED WITHIN THIS DOCUMENT.
3.COMPLY WITH THE FOLLOWING:
3.1.UNIFIED DEVELOPMENT CODE CITY CODE OF
ORDINANCES CHAPTER 18 BUILDINGS AND
BUILDING REGULATIONS.
4.PROVIDE A SPECIAL INSPECTIONS LETTER IN
COMPLIANCE WITH THE 2012 INTERNATIONAL
BUILDING CODE SECTIONS 1704-SPECIAL
INSPECTIONS, CONTRACTOR RESPONSIBILITY AND
STRUCTURAL OBSERVATIONS AND 1705-REQUIRED
VERIFICATION AND INSPECTION.
5.USE ONLY PLANNING APPROVED SITE PLAN.
COM
A
L
C
O
U
N
T
Y
H
U
B
E
R
T
U
S
R
D
.
FM
4
8
2
UTILITY
ENGINEERING
GROUP PLLC
Texas Engineering Firm F-18712
191 N. Union Ave NEW BRAUNFELS, TEXAS 78130 PH: (830) 214-0521
UEG
UT
I
L
I
T
Y
EN
G
I
N
E
E
R
I
N
G
GR
O
U
P
PL
L
C
Te
x
a
s
E
n
g
i
n
e
e
r
i
n
g
F
i
r
m
F
-
1
8
7
1
2
19
1
N
.
U
n
i
o
n
A
v
e
N
E
W
B
R
A
U
N
F
E
L
S
,
T
E
X
A
S
7
8
1
3
0
P
H
:
(
8
3
0
)
2
1
4
-
0
5
2
1
UEG
GENERAL NOTES
1.CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE
RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE CONSTRUCTION OF
THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY; THAT THIS
REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL
WORKING HOURS; AND THAT THE CONTRACTOR SHALL DEFEND INDEMNITY AND
HOLD THE OWNER AND THE ENGINEER HARMLESS FROM ANY AND ALL LIABILITY,
REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF THE WORK ON
THIS PROJECT, EXCEPTING FROM LIABILITY ARISING FROM SOLE NEGLIGENCE
OF THE OWNER OR ENGINEER.
2.CONTRACTOR SHALL NOTIFY THE ENGINEER AND ALL RESPECTIVE
GOVERNMENTAL OR UTILITY AGENCIES AFFECTED BY CONSTRUCTION 72
HOURS PRIOR TO STARTING CONSTRUCTION. ANY TIE-IN SHALL BE
COORDINATED BY THE CONTRACTOR WITH THE PUBLIC WORKS DEPARTMENT,
AT LEAST 48 HOURS IN ADVANCE.
3.CONTRACTOR IS REQUIRED TO VERIFY PROJECT ELEVATIONS. "MATCH
EXISTING" SHALL BE UNDERSTOOD TO SIGNIFY VERTICAL AND HORIZONTAL
ALIGNMENT.
4.ANY DISCREPANCY OR CONFLICT WITHIN THE DRAWINGS AND SPECIFICATIONS
SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER. DISCREPANCIES OR
CONFLICTS NOT BROUGHT TO THE ENGINEERS ATTENTION AND CLARIFIED
DURING BIDDING OF THE PROJECT WILL BE DEEMED TO HAVE BEEN BID OR
PROPOSED IN THE MORE COSTLY MANNER, AND THE BETTER QUALITY OR
GREATER QUANTITY OF THE WORK SHALL BE PROVIDED BY THE CONTRACTOR
IN ACCORDANCE WITH ENGINEERS INTERPRETATION. ALL ITEMS, WORK, AND
IMPROVEMENTS SHOWN OR INDICATED IN THE CONSTRUCTION DOCUMENTS
SHALL BE COMPLETED FOR THE PRICES BID, WHETHER OR NOT A SEPARATE
PAY ITEM IS INCLUDED IN THE CONTRACT.
5.THE CONTRACTOR SHALL MAINTAIN "AS-BUILT" DRAWINGS THROUGH THE
COURSE OF CONSTRUCTION AND SHALL SUBMIT SAME TO THE ENGINEER FOR
APPROVAL PRIOR TO FINAL ACCEPTANCE OF THE WORK BY OWNER.
6.THE CONTRACTOR WILL SELECT, EMPLOY, AND PAY FOR SERVICES OF AN
INDEPENDENT TESTING LABORATORY TO PERFORM INSPECTION AND TESTING
IDENTIFIED IN THE PUBLIC WORKS TECHNICAL SPECIFICATION SECTION 01452.
EMPLOYMENT OF A TESTING LABORATORY BY THE CONTRACTOR SHALL NOT
RELIEVE CONTRACTOR OF ITS OBLIGATION TO PERFORM WORK IN
ACCORDANCE WITH REQUIREMENTS OF CONTRACT DOCUMENTS. COPIES OF
REPORTS TO BE SUBMITTED TO THE CITY FOR REVIEW.
7.THE CONTRACTOR SHALL FURNISH ALL ASSISTANCE REQUIRED OF HIM BY ALL
INSPECTORS IN OBTAINING SAMPLES AT THE EXPENSE OF THE CONTRACTOR.
8.IF IN THE OPINION OF THE INSPECTOR, BASED ON TESTING SERVICE REPORTS
AND INSPECTION, MATERIALS OR COMPACTION ARE BELOW THE SPECIFIED
REQUIREMENTS THE CONTRACTOR SHALL CORRECT THE DEFICIENCY AND
RE-TEST TO OBTAIN THE SPECIFIED PARAMETERS AT NO ADDITIONAL EXPENSE.
9.DESIGN STANDARDS REQUIRED:
A.PROJECT CONTRACT DOCUMENTS AND TECHNICAL SPECIFICATIONS.
B.CITY OF SCHERTZ PUBLIC WORKS STANDARD CONSTRUCTION
SPECIFICATIONS.
10.UNLESS OTHERWISE SHOWN IN THESE PLANS, SIDEWALKS WILL BE
CONSTRUCTED CONCURRENT WITH MAIN LOT STRUCTURE.
11.ROUGH GRADING MUST BE DONE ON ALL LOTS PRIOR TO SUBDIVISION
PRELIMINARY ACCEPTANCE.
12.ALL PAVEMENTS, DRIVEWAYS, SIDEWALKS, CURBING, GUTTERS, FENCES,
POLES, MAILBOXES, SIGNS, TREES, SHRUBBERY, LAWNS, SOD OR OTHER
PROPERTY AND SURFACE STRUCTURES ON OR ADJACENT TO THE PROJECT
SITE NOT SHOWN TO BE REMOVED IN PLANS, THAT ARE DAMAGED, DISTURBED,
REMOVED OR DESTROYED BY THE CONTRACTOR DURING THE WORK SHALL BE
REPLACED OR RETURNED TO A CONDITION EQUAL TO THAT BEFORE THE WORK
BEGAN. CONTRACTOR TO SUPPORT AND KEEP INTACT STORM DRAINS AND
INLET STRUCTURES. ANY DAMAGES INCURRED WILL BE AT CONTRACTOR'S
EXPENSE.
UTILITIES
13.DUE TO FEDERAL REGULATIONS TITLE 49, PART 192.181, THE LOCAL GAS
COMPANY. MUST MAINTAIN ACCESS TO GAS VALVES AT ALL TIMES. THE
CONTRACTOR MUST PROTECT AND WORK AROUND ANY GAS VALVES THAT ARE
IN THE PROJECT AREA.
14.THE EXISTENCE AND LOCATION OF UNDERGROUND UTILITIES INDICATED IN
THESE PLANS ARE TAKEN FROM THE BEST RECORDS AVAILABLE AND ARE NOT
GUARANTEED, BUT SHALL BE INVESTIGATED AND VERIFIED BY THE
CONTRACTOR BEFORE STARTING WORK. THE CONTRACTOR SHALL BE HELD
RESPONSIBLE FOR ANY DAMAGE TO, AND FOR MAINTENANCE AND PROTECTION
OF THE EXISTING UTILITIES EVEN IF THEY ARE NOT SHOWN ON THE PLANS.
CONTRACTOR SHALL CONTACT ANY UTILITIES ENCOUNTERED FORTY-EIGHT
HOURS (48) HOURS PRIOR TO EXCAVATION OPERATION.
15.THE FOLLOWING IS A LIST OF TELEPHONE NUMBERS OF THE UTILITY LOCATORS
FOR THE VARIOUS UTILITIES THAT MAY BE ENCOUNTERED:
TEXAS ONE CALL .................................................. 1-800-245-4545 (1-800-DIG-TESS)
C.C.M.A. .................................................................. (210)-658-6241
CITY PUBLIC SERVICE........................................... 1-800-545-6005
CENTERPIONT ENERGY ENTEX........................... (210)-659-6788
G.V.E.C. ................................................................... (210)-672-2871
NEW BRAUNFELS UTILITY..................................... (830)-629-8400
TIME WARNER CABLE............................................ (210)-352-4472
AT&T......................................................................... 1-800-828-5127
TxDOT NEW BRAUNFELS....................................... 1-800-644-4773
CITY OF SCHERTZ PUBLIC WORKS DEPT............ (210)-619-1800
GREEN VALLEY WATER DISTRICT........................ (830)-914-2330
SCHERTZ SEGUIN LOCAL GOV'T CORP............... (830)-401-2409
GREEN VALLEY TELEPHONE COMPANY.............. (830)-885-8277
GREEN VALLEY SPECIAL UTILITY DISTRICT........ (830)-914-2330
16.NO VALVES IN THE OWNER'S WATER DISTRIBUTION SYSTEM SHALL BE
OPERATED BY THE CONTRACTOR WITHOUT PRIOR PERMISSION OF THE OWNER.
THE CONTRACTOR SHALL NOTIFY THE OWNER WHEN A VALVE IS TO BE
OPERATED AND SHALL ONLY OPERATE THE VALVE IN THE PRESENCE OF THE
OWNER'S REPRESENTATIVE. COORDINATE ALL SHUTDOWN OF MAINS FOR
TIE-INS WITH OWNER 72 HOURS PRIOR TO WORK BEING COMPLETED. THE
CONTRACTOR SHALL INSPECT THE MATERIALS FOR DEFECTS AT THE TIME
THEY ARE UNLOADED, AND ANY MATERIALS FOUND DEFECTIVE SHALL BE
REMOVED FROM THE SITE. ALL WATER WORKS MATERIAL OR SCRAP OF
WHATEVER NATURE REMOVED BY THE CONTRACTOR IN THE COURSE OF THE
WORK SHALL REMAIN THE PROPERTY OF THE OWNER. SALVAGED MATERIALS
SHALL BE DELIVERED TO AND UNLOADED AT THE CITY PUBLIC WORKS
DEPARTMENT BY THE CONTRACTOR UNDER OBSERVATION OF AND AT THE
DIRECTION OF THE OWNER. ITEMS TOO HEAVY TO BE HANDLED MANUALLY WILL
BE UNLOADED BY EQUIPMENT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
ALL MATERIALS UNTIL THEY HAVE BEEN TURNED IN TO THE OWNER AND UNTIL
A RECEIPT FOR THEM HAS BEEN ISSUED BY THE OWNER.
17.PLUG EXISTING SEWER BEFORE INSTALLING ANY NEW SEWER MAIN.
18.CONTRACTOR TO TAKE APPROPRIATE MEASURES TO PROTECT EXISTING
SANITARY SEWER LATERALS AND WATER SERVICES SHOWN IN PLANS. ANY
REPAIRS TO BE MADE AT CONTRACTORS EXPENSE.
19.PROVIDE BLUE PANTED "V" ETCHED IN CURB TO IDENTIFY VALVES. PROVIDE
BLUE PANTED "X" ETCHED IN CURB TO IDENTIFY METER BOXES.
20.NEW WATER MAINS TO BE PVC C900 DR14, UNLESS OTHERWISE SHOWN IN
PLANS AND APPROVED BY PUBLIC WORKS OR ENGINEERING. HYDROSTATIC
TESTING WILL BE PERFORMED UNDER THE SUPERVISION OF THE CITY
INSPECTOR AT 200 PSI FOR 4 HOURS.
21.CONTRACTORS SHOULD USE HTH FOR DISINFECTION OF WATER LINES (NOT
CHLORINE INJECTION) UNLESS APPROVED OTHERWISE PRIOR TO ISSUANCE OF
PERMIT.
22.NEW WATERLINES SHALL BE TIED INTO EXISTING WATER SYSTEM UNDER THE
SUPERVISION OF CITY PERSONNEL NO LATER THAN 14 DAYS AFTER PASSING
BACTERIOLOGICAL TESTS.
23.THE CONTRACTOR IS RESPONSIBLE TO ENSURE THAT NO OVERFLOWS OR
SPILLAGE OF SEWER OCCURS. SHOULD THIS OCCUR, THE CONTRACTOR SHALL:
A.IDENTIFY THE SOURCE OF THE SPILL AND ATTEMPT TO ELIMINATE ANY
ADDITIONAL SPILLAGE.
B.NOTIFY THE CITY OF SCHERTZ PUBLIC WORKS.
C.CONTAIN THE SPILL IN PLACE AND AVOID CONTAMINATION OF STREAMS.
D.DISINFECT THE AREA OF THE SPILL WITH A MIXTURE OF HTH CHLORINE AND
WATER.
E.ALL WORK SHALL BE DONE ACCORDING TO GUIDELINES SET BY THE TEXAS
COMMISSION ON ENVIRONMENTAL QUALITY AND THE CITY OF SCHERTZ.
24.CONTRACTOR TO PROVIDE NOTICE TO RESIDENTS OF SHUTDOWN OF MAIN.
CONTRACTOR TO NOTIFY RESIDENTS OF WORK WITHIN THEIR PROPERTY AND
OF THE RELOCATION OF METERS. ANY COMPLAINTS BY RESIDENTS ARE TO BE
PASSED IMMEDIATELY TO THE CITY INSPECTOR OR TO THE MAIN PUBLIC
WORKS OFFICE. TAKE APPROPRIATE MEASURES TO PROTECT EXISTING
SANITARY SEWER LATERALS SHOWN IN PLANS. ANY REPAIRS TO BE MADE AT
CONTRACTORS EXPENSE.
25.ABANDONED CUSTOMER LINES SHALL BE CAPPED OR PLUGGED AT THE
PROPERTY LINE.
26.ASBESTOS PIPE REMOVAL AND DISPOSAL IS THE CONTRACTORS
RESPONSIBILITY.
TREES & VEGETATION
27.THE CONTRACTOR SHALL VERIFY WHICH TREES ARE TO BE SAVED AND
PROTECTED PRIOR TO COMMENCING CONSTRUCTION. DURABLE FENCE
PROTECTION BARRIERS SHALL BE INSTALLED AROUND ALL TREES TO BE SAVED
WITH FENCE PLACEMENT A MINIMUM OF 10 FEET FROM TREE CANOPY OR THE
DRIP LINE, WHICHEVER IS GREATER.
28.THE CONTRACTOR SHALL NOT DISTURB AREAS AROUND EXISTING TREES TO BE
SAVED.
29.THE CONTRACTOR SHALL PROTECT EXISTING GRASS, LANDSCAPING AND
TREES NOT IN DIRECT CONFLICT WITH PROPOSED IMPROVEMENTS DURING
CONSTRUCTION. GRASSED AREAS DAMAGED DURING CONSTRUCTION SHALL BE
RESTORED BY THE CONTRACTOR WITH TOPSOIL AND SODDED.
30.THE CONTRACTOR SHALL REMOVE ALL VEGETATION, TREES, STUMPS,
GRASSES, ORGANIC SOIL, DEBRIS, AND DELETERIOUS MATERIALS IN CONFLICT
WITH IMPROVEMENTS.
31.AFTER THE CONTRACTOR HAS REMOVED MATERIALS AS DESCRIBED ABOVE, HE
SHALL STRIP SUITABLE TOPSOIL AND STOCKPILE FOR LANDSCAPING USE.
32.THE CONTRACTOR SHALL EXERCISE EXTRA CARE TO AVOID DAMAGE TO TREES
AND ORNAMENTAL SHRUBS PLANTED AND MAINTAINED BY PROPERTY OWNERS
IN THE TERRACES FRONTING THEIR PROPERTY.
33.CONTRACTOR SHALL COMPENSATE OWNER FOR DAMAGE TO TREES NOT
SHOWN TO BE REMOVED IN PLANS.
34.OAK TREES DAMAGED DURING CONSTRUCTION SHALL BE SEALED WITHIN SIX
HOURS OF DAMAGE TO PREVENT INFECTION BY OAK WILT.
NPDES
35.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PREPARATION AND
IMPLEMENTATION OF THE STORMWATER POLLUTION PREVENTION PLAN
(SWPPP), INCLUDING COMPLYING WITH ALL APPLICABLE REGULATIONS
RELATED TO NPDES & TPDES, AND SUBMITTING REQUIRED NOTIFICATION OF
INTENT AND TERMINATION. THIS IS TO BE PAID FOR UNDER "STORM WATER
POLLUTION PREVENTION PLAN" ITEM.
36.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SITE CONDITIONS DURING
CONSTRUCTION AND UNTIL THE PROJECT IS ACCEPTED. THE CONTRACTOR
SHALL BE RESPONSIBLE FOR OBTAINING THE STORMWATER POLLUTION
PREVENTION PLAN, UNDERSTAND THE REQUIREMENTS FOR THE PLAN, AND
SHALL BE RESPONSIBLE FOR IMPLEMENTING THE PLAN. THIS IS TO BE
INCLUDED UNDER SECTION 01410 "STORM WATER POLLUTION PREVENTION
PLAN". ALL FINES IMPOSED FOR NOT IMPLEMENTING OR MAINTAINING SWPPP
MEASURES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
TRAFFIC
37.THE CONTRACTOR SHALL PROVIDE ACCESS FOR RESIDENCES AND
BUSINESSES.
38.THE CONTRACTOR SHALL PROVIDE ACCESS FOR THE DELIVERY OF MAIL BY THE
U.S. POSTAL SERVICE.
39.THE CONTRACTOR WILL BE REQUIRED TO FURNISH BARRICADES, WARNING
SIGNS, LIGHTS, FLARES, FLAGS, FLAGMEN, ETC. WHERE NECESSARY AND AS
DIRECTED BY THE ENGINEER, PARTICULARLY IN THOSE AREAS OF IMMEDIATE
WORK.
40.BATTERY FLASHERS SHALL BE USED AND NUMBER SHALL BE EQUAL OR
GREATER THAN INDICATED ON BARRICADING STANDARDS. WHEN A CLASS I
BARRICADE PANEL OR CLASS II BARRICADE IS USED, EACH SHOULD BE
EQUIPPED WITH A MINIMUM OF TWO (2) LIGHTS. ALL WARNING SIGNS NOT
MOUNTED ON BARRICADES SHALL HAVE ONE (1) LIGHT.
41.BATTERY FLASHERS SHALL CONFORM TO PART V, SECTION D, LIGHTING
DEVICES, TEXAS MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES FOR
STREETS AND HIGHWAYS.
42.CONTRACTOR RESPONSIBLE FOR SUBMITTING A TRAFFIC CONTROL PLAN,
PREPARED BY A REGISTERED PROFESSIONAL ENGINEER, TO THE CITY FOR
APPROVAL 5 WORKING DAYS PRIOR TO COMMENCING WORK. PLAN SHOULD
FOLLOW REQUIREMENTS OF TMUTCD, LATEST EDITION.
43.ALL TRENCHING AND CUT PAVEMENT SHALL BE RESTORED SUCH THAT LOCAL
ACCESS MAY BE RESUMED AS SOON AS POSSIBLE.
44.RESTRICT TOTAL LENGTH OF DISTRIBUTED MATERIALS ALONG THE ROUTE OF
CONSTRUCTION TO 1,000 LINEAR FEET UNLESS OTHERWISE APPROVED IN
WRITING BY PUBLIC WORKS.
45.MAINTAIN THROUGH TRAFFIC ALONG ALONG ANY PUBLIC ROADWAYS FOR THE
DURATION OF THE PROJECT.
46.COORDINATE SHUT DOWN ROAD WITH CITY OF SCHERTZ 5 DAYS PRIOR TO
SHUTDOWN.
SITE RESTORATION:
47.RESTORATION OF PROJECT AREA AFFECTED BY CONSTRUCTION ACTIVITIES IN
PUBLIC AND PRIVATE PROPERTY, INCLUDING RIGHT-OF-WAYS AND EASEMENTS
(TOPSOIL AND HYDROMULCH), PAVEMENT, DRIVEWAYS, DRAINAGE
STRUCTURES, FENCES, LAWNS (TOPSOIL AND BLOCK SODDING), AND
LANDSCAPING WILL BE COVERED BY SPECIFICATION AND BID ITEM “SITE
RESTORATION”.
48.PAYMENT FOR RESTORATION OF PROJECT SITE DISTURBED BY UTILITY
CONSTRUCTION OPERATIONS IS ON A LINEAR FOOT. MEASUREMENT WILL BE
AS PROVIDED FOR CORRESPONDING UTILITY IN EACH SPECIFICATION SECTION.
NO SEPARATE PAYMENT MADE FOR BRANCH PIPE, VALVES, SERVICES, YARD
PIPING AND OTHER ASSOCIATED WORK FOR UTILITIES. MEASUREMENT FOR
RESTORATION WITH MULTIPLE UTILITIES WITHIN THE SAME RIGHT-OF-WAY WILL
BE ON A LINEAR FOOT BASIS FOR ONLY ONE UTILITY.
49.PAYMENT INCLUDES REQUIRED SITE RESTORATION WITHIN THE RIGHT-OF-WAY
OR EASEMENT REGARDLESS OF SIZE OR TYPE OF PIPE, METHOD OF
CONSTRUCTION, PAVED OR UNPAVED AREAS OR THICKNESS AND WIDTH OF
PAVEMENT.
50.NO SEPARATE PAYMENT MADE FOR SITE RESTORATION FOR SERVICE
CONNECTIONS OR YARD PIPING UNDER THIS SECTION. INCLUDE COST IN
APPROPRIATE ITEM.
51.ALL DISTURBED AREAS TO BE RE-VEGETATED TO 85% OF APPROVED GRASSES
PRIOR TO THE ACCEPTANCE OF PERMIT CLOSEOUT.
52.ROUGH GRADING, INCLUDING TREE REMOVAL MUST BE DONE ON ALL LOTS
PRIOR TO SUBDIVISION PRELIMINARY ACCEPTANCE.
TXDOT NOTE:
53.NO WORK AND NO STORAGE OF MATERIALS WILL BE PERFORMED IN TXDOT
RIGHT-OF-WAY, UNLESS THE APPROPRIATE DENSITIES HAVE BEEN OBTAINED.
54.ALL TXDOT REQUIRED PERMITS MUST BE OBTAINED AND PROVIDED BY THE
CITY BY THE CONTRACTOR. ALL PERMITS FOR UTILITY WORK WITHIN THE TXDOT
R.O.W. WILL BE OBTAINED AND PROVIDED TO THE CITY. ALL PLANS AND
REQUIRED SUBMITTALS WILL BE PROVIDED BY THE CONTRACTOR AT REQUEST
OF THE CITY.
CONTRACTOR REQUIREMENTS FOR SITE CLEARING, GRADING, AND EROSION
CONTROL DESIGN AND CONSTRUCTION NOTES.
55.NO DISTURBANCE OF PROPOSED CONSERVATION EASEMENTS, NATURAL
BUFFERS, OR WATER BODIES IS PERMITTED. THE CONTRACTOR SHALL LOCATE
THESE AREAS ON SITE AND BARRICADE THEM TO AVOID ANY UNAUTHORIZED
CLEARING. BARRICADES AND OTHER PROTECTIVE FENCING ARE TO BE
LOCATED AT THE DRIP LINE OF EXISTING NATIVE TREES OR A MINIMUM OF 10
FEET FROM TREE CANOPY OR THE DRIP LINE, WHICHEVER IS GREATER.
56.SPECIMEN AND HISTORIC TREES, CONSERVATION EASEMENTS, NATURAL
VEGETATION BUFFERS, AND SIMILAR AREAS MUST BE PROTECTED BY
BARRICADES OR FENCING PRIOR TO CLEARING. BARRICADES ARE TO BE SET AT
THE DRIP LINE OF THE TREES AND MAINTAINED THROUGHOUT THE DURATION
OF THE PROJECT. BARBED WIRE IS NOT PERMITTED AS A PROTECTIVE BARRIER.
57.WHERE A CHANGE OF GRADE OCCURS AT THE DRIP LINE OF A SPECIMEN TREE,
SILT FENCES WILL BE REQUIRED DURING CONSTRUCTION AND RETAINING
WALLS MUST BE INSTALLED PRIOR TO FINAL ACCEPTANCE BY THE CITY.
58.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO HAVE ALL
PROTECTIVE VEGETATION BARRICADES AND EROSION CONTROL STRUCTURES
AND MEASURES IN PLACE PRIOR TO THE COMMENCEMENT OF ANY
EARTHWORK, INCLUDING PRELIMINARY GRUBBING. THESE MEASURES INCLUDE,
BUT ARE NOT LIMITED TO, TEMPORARY CONSTRUCTION FENCES, SYNTHETIC
JUTE BALES, WATTLES, &/OR HAVE BEST MANAGEMENT PRACTICES (BMP'S) AS
REQUIRED, SILT FENCES, AND FLOATING TURBIDITY BARRIERS. FURTHER, IT
SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN ALL
EROSION CONTROL DEVICES THROUGHOUT THE DURATION OF THE ENTIRE
PROJECT. MAINTENANCE SHALL INCLUDE PERIODIC INSPECTION AND REMOVAL
OF DEBRIS ABUTTING EROSION CONTROL DEVICES.
59.PRIOR TO THE INSTALLATION OF ANY FILL MATERIALS ON SUBJECT SITE, SILT
FENCES SHALL BE INSTALLED (1) ALONG SUBJECT SITE BOUNDARY AND
PROPERTY LINES, (2) AT THE EDGE OF CONSERVATION EASEMENTS AND
WETLANDS, (3) ADJACENT TO NATURAL LANDSCAPE BUFFERS, (4) AROUND THE
PERIMETER OF EXISTING STORM WATER TREATMENT FACILITIES, AND (5) AT
ANY ADDITIONAL AREAS THAT THE CITY DEEMS NECESSARY TO BE PROTECTED
FROM POTENTIAL EROSION IMPACTS DURING CONSTRUCTION. THESE
CONDITIONS SHALL APPLY IN ALL INSTANCES WHERE FILL MATERIAL IS BEING
INSTALLED WITHIN 25 FEET OF ANY OF THE AFOREMENTIONED LOCATIONS.
WHILE THESE ITEMS REPRESENT THE MINIMUM REQUIREMENTS, THE CITY
RESERVES THE RIGHT TO IMPOSE ADDITIONAL PROTECTIVE MEASURES, AS
DETERMINED DURING ACTUAL SITE VISITS CONDUCTED AS PART OF THE
STANDARD REVIEW OF THE SITE THROUGHOUT PROJECT CONSTRUCTION.
60.AT A MINIMUM, THE CONTRACTOR SHALL SEED AND/OR MULCH ALL DISTURBED
AREAS. 85% SUFFICIENT GRASS COVERAGE IS TO BE ESTABLISHED BEFORE
PERMIT EXPIRATION.
61.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR THROUGH
SCHEDULING, TO MINIMIZE THE DISTURBANCE OF SITE AREAS THAT HAVE BEEN
BROUGHT TO THEIR PROPOSED FINAL GRADE. WITHIN SEVEN (7) DAYS OF
BRINGING A SUBJECT AREA TO ITS FINAL GRADE OR INACTIVITY IN
CONSTRUCTION, THE CONTRACTOR SHALL INSTALL SEED AND MULCH OR SOD,
AS REQUIRED. ANY PROJECT THAT IS INACTIVE FOR A PERIOD OF 30 DAYS OR
MORE SHALL BE STABILIZED TO THE SATISFACTION OF THE CITY OF SCHERTZ.
62.ONCE AN AREA IS SEEDED OR SODDED, IT MUST BE MAINTAINED BY THE
CONTRACTOR TO ALLOW THE GRASS TO BECOME ESTABLISHED. IF THE GRASS
IS NOT ESTABLISHED WITHIN TWO WEEKS THE CITY MAY REQUIRE THE
CONTRACTOR TO RE-SEED OR A NON-VEGETATIVE OPTION MAY BE EMPLOYED.
63.ABSOLUTELY NO BURYING OF CLEARED MATERIALS IS PERMITTED.
64.THE REMOVAL OF ALL VEGETATION AND TOPSOIL ON THE FUTURE ROADWAY,
PARKING AND BUILDING LOT AREAS IS REQUIRED TO BE COMPLETED PRIOR TO
THE PLACEMENT OF FILL ON THOSE AREAS. THE TOPSOIL MAY BE
TEMPORARILY STOCKPILED AND USED AS TOPSOIL OVER OVER PROPOSED
GREEN AREAS SUCH AS PLANT BEDS, SODDED AREAS, AND WHERE TREES ARE
TO BE INSTALLED OR RELOCATED.
65.A SIGNED, DATED, AND SEALED LETTER FROM A SOILS ENGINEER OR THE
ENGINEER OF RECORD CERTIFYING THAT THE AREAS TO BE FILLED HAVE BEEN
STRIPPED OF ORGANIC MATERIALS, MUST BE SUBMITTED TO THE CITY PRIOR
TO FILLING.
66.FILL MATERIAL IS TO BE PLACED IN ONE FOOT LIFTS AND COMPACTED TO THE
APPROPRIATE DENSITY (95% FOR PAVED AREAS AND 95% FOR BUILDING PADS
AND ALL OTHER AREAS AS PER ASTM D-698).
67.DURING SUBDIVISION DEVELOPMENT WHEN FUTURE BUILDING LOTS ARE FILLED
AS PART OF THE OVERALL SUBDIVISION IMPROVEMENTS, COMPACTION TEST
REPORTS MUST BE PERFORMED ON THE BUILDING LOTS AT 300 FOOT
INTERVALS. THESE TESTS ARE TO BE PERFORMED IN ONE-FOOT VERTICAL
INCREMENTS. THE RESULTS OF THESE TESTS ARE TO BE SUBMITTED TO THE
CITY UPON COMPLETION OF THE TESTS.
68.IF ANY MUCK MATERIAL IS DISCOVERED, IT SHALL BE REQUIRED TO BE
REMOVED AND REPLACED WITH A SUITABLE MATERIAL THAT IS PROPERLY
BACKFILLED, COMPACTED AND TESTED USING AASHTO T-180 MODIFIED
PROCTOR METHOD.
69.STOCKPILING IS NOT GENERALLY PERMITTED BY THE CITY. WHEN ALLOWED,
STOCKPILES SHALL NOT EXCEED SIX FEET IN HEIGHT MEASURED FROM THE
ORIGINAL GRADE. AT A MINIMUM, STOCK PILES THAT WILL REMAIN IN PLACE IN
EXCESS OF TWENTY DAYS SHOULD BE SEEDED AND MULCHED IMMEDIATELY
UPON PLACEMENT OF THE FINAL LIFT.
70.SOILS ARE TO BE STABILIZED BY WATER OR OTHER MEANS DURING
CONSTRUCTION. THIS IS INTENDED TO REDUCE SOIL EROSION AND THE IMPACT
TO NEIGHBORING COMMUNITIES. ADEQUATE WATERING METHODS SHOULD BE
EMPLOYED TO ALLOW DAILY COVERAGE OF THE ENTIRE LIMITS OF ALL AREAS
THAT DO NOT HAVE AN ESTABLISHED VEGETATIVE COVER. METHODS TO BE
EMPLOYED INCLUDE, BUT ARE NOT LIMITED TO, WATER TRUCKS, PERMANENT
IRRIGATION SYSTEMS, TEMPORARY SPRINKLER SYSTEMS OPERATED BY
PUMPING UNITS CONNECTED TO WET RETENTION PONDS, WATER CANNONS,
TEMPORARY IRRIGATION SYSTEMS MOUNTED ATOP STOCKPILE AREAS, AND
OTHER METHODS AS DEEMED NECESSARY BY THE CITY.
71.ALL FILL MATERIALS LOCATED BENEATH STRUCTURES AND PAVEMENT SHALL
CONSIST OF CLEAN GRANULAR SAND FREE FROM ORGANICS AND SIMILAR
MATERIAL THAT COULD DECOMPOSE.
72.ALL FILL TO BE PLACED IN LANDSCAPED AREAS SHALL HAVE A PH RANGE
BETWEEN 5.5 AND 6.5, BE ORGANIC IN NATURE, FREE OF ROCKS AND DEBRIS,
OR MATCH NATIVE EXISTING SOILS.
73.OWNER/CONTRACTOR SHALL FILE A "NOTICE OF INTENT TO USE GENERAL
PERMIT FOR STORM WATER DISCHARGE FOR STORM WATER DISCHARGES
ASSOCIATED WITH CONSTRUCTION ACTIVITIES" WITH THE TEXAS POLLUTION
DISCHARGE ELIMINATION SYSTEM" IN COORDINATION WITH THE TEXAS
COMMISSION OF ENVIRONMENTAL QUALITY. CONTRACTOR SHALL BE REQUIRED
TO COMPLY WITH ALL PROVISIONS OF THE GENERIC PERMIT INCLUDING BUT
NOT LIMITED TO:
A.PROVIDE SUCH EROSION AND SEDIMENT CONTROL MEASURES AS MAY BE
NECESSARY TO PREVENT DISCHARGE OF POLLUTANTS FROM THE SITE FROM
THE START OF CONSTRUCTION UNTIL THE FINAL GROUND COVER HAS BEEN
ESTABLISHED.
B.WORK WITH CITY INSPECTORS TO MAKE WEEKLY INSPECTIONS/REPORTS OF
THE CONDITION OF EROSION AND SEDIMENT CONTROL MEASURES.
C.WORK WITH CITY INSPECTORS TO MAKE INSPECTIONS/REPORTS OF THE
CONDITION OF EROSION AND SEDIMENT CONTROL MEASURES WITHIN 24
HOURS OF EVERY RAINFALL EVENT EXCEEDING ONE-HALF INCH.
D.MAINTAIN ALL EROSION AND SEDIMENT CONTROL MEASURES THROUGHOUT
CONSTRUCTION.
E.ADD EROSION AND SEDIMENT CONTROL MEASURES AS SITE CONDITIONS
CHANGE.
F.REMOVE TEMPORARY EROSION/SEDIMENT CONTROL MEASURES AFTER
SUBSTANTIAL RE-VEGETATION AND/OR PRIOR TO THE END OF THE PERMIT
EXPIRATION.
36
GN-1
DK
PND
PND
GE
N
E
R
A
L
N
O
T
E
S
IH
-
3
5
R
I
A
T
A
L
I
F
T
S
T
A
T
I
O
N
R
E
L
O
C
A
T
I
O
N
A
N
D
OF
F
S
I
T
E
S
E
W
E
R
I
M
P
R
O
V
E
M
E
N
T
S
8032-03
30 January, 2023
UT
I
L
I
T
Y
EN
G
I
N
E
E
R
I
N
G
GR
O
U
P
PL
L
C
Te
x
a
s
E
n
g
i
n
e
e
r
i
n
g
F
i
r
m
F
-
1
8
7
1
2
19
1
N
.
U
n
i
o
n
A
v
e
N
E
W
B
R
A
U
N
F
E
L
S
,
T
E
X
A
S
7
8
1
3
0
P
H
:
(
8
3
0
)
2
1
4
-
0
5
2
1
UEG
TEXAS COMMISSION ON ENVIRONMENTAL QUALITY
LIFT STATIONS AND FORCE MAINS
GENERAL CONSTRUCTION NOTES
1.THIS LIFT STATION AND/OR FORCE MAIN MUST BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE TEXAS COMMISSION ON
ENVIRONMENTAL QUALITY'S (TCEQ) EDWARDS AQUIFER RULES 30 TEXAS ADMINISTRATIVE CODE (TAC) §213.5(C), THE DESIGN CRITERIA
FOR DOMESTIC WASTEWATER SYSTEMS 30 TAC CHAPTER 217, AND IF ACCEPTABLE TO THE CITY OF SCHERTZ ENGINEERING
DEPARTMENT.
2.ANY MODIFICATION TO THE ACTIVITIES DESCRIBED IN THE REFERENCED LIFT STATION/FORCE MAIN SYSTEM APPLICATION FOLLOWING
THE DATE OF APPROVAL MAY REQUIRE THE SUBMITTAL OF A LIFT STATION/FORCE MAIN SYSTEM APPLICATION TO MODIFY THIS
APPROVAL, INCLUDING THE PAYMENT OF APPROPRIATE FEES AND ALL INFORMATION NECESSARY FOR ITS REVIEW AND APPROVAL.
3.PRIOR TO COMMENCING ANY REGULATED ACTIVITY, THE APPLICANT OR HIS AGENT MUST NOTIFY THE LOCAL REGIONAL OFFICE, IN
WRITING, OF THE DATE ON WHICH THE REGULATED ACTIVITY WILL BEGIN.
4.UPON COMPLETION OF THE WET WELL EXCAVATION, A GEOLOGIST MUST CERTIFY THAT THE EXCAVATION HAS BEEN INSPECTED FOR
THE PRESENCE OF SENSITIVE FEATURES AND THE CERTIFICATION MUST BE SUBMITTED TO THE APPROPRIATE REGIONAL OFFICE.
FURTHER ACTIVITIES MAY NOT PROCEED UNTIL THE EXECUTIVE DIRECTOR HAS REVIEWED AND APPROVED THE METHODS PROPOSED
TO PROTECT ANY SENSITIVE FEATURE AND THE EDWARDS AQUIFER FROM POTENTIALLY ADVERSE IMPACTS TO WATER QUALITY FROM
THE LIFT STATION. CONSTRUCTION MAY CONTINUE IF THE GEOLOGIST CERTIFIES THAT NO SENSITIVE FEATURE OR FEATURES ARE
PRESENT.
5.IF ANY SENSITIVE FEATURES ARE DISCOVERED DURING THE WASTEWATER LINE TRENCHING ACTIVITIES, ALL REGULATED ACTIVITIES
NEAR THE SENSITIVE FEATURE MUST BE SUSPENDED IMMEDIATELY. THE APPLICANT MUST IMMEDIATELY NOTIFY THE APPROPRIATE
REGIONAL OFFICE OF THE TEXAS COMMISSION ON ENVIRONMENTAL QUALITY OF THE FEATURE DISCOVERY. A GEOLOGIST'S
ASSESSMENT OF THE LOCATION AND EXTENT OF THE FEATURE DISCOVERED MUST BE REPORTED TO THAT REGIONAL OFFICE IN
WRITING WITHIN TWO WORKING DAYS. THE APPLICANT MUST SUBMIT A PLAN FOR ENSURING THE STRUCTURAL INTEGRITY OF THE
SEWER LINE OR FOR MODIFYING THE PROPOSED COLLECTION SYSTEM ALIGNMENT AROUND THE FEATURE. THE REGULATED
ACTIVITIES NEAR THE SENSITIVE FEATURE MAY NOT PROCEED UNTIL THE EXECUTIVE DIRECTOR HAS REVIEWED AND APPROVED THE
METHODS PROPOSED TO PROTECT THE SENSITIVE FEATURE AND THE EDWARDS AQUIFER FROM ANY POTENTIALLY ADVERSE IMPACTS
TO WATER QUALITY WHILE MAINTAINING THE STRUCTURAL INTEGRITY OF THE LINE.
6.LIFT STATIONS SHALL BE DESIGNED TO WITHSTAND AND OPERATE DURING A 100-YEAR FLOOD EVENT AND SHALL BE ACCESSIBLE
DURING A 25-YEAR FLOOD. ALL LIFT STATIONS SHALL BE INTRUDER-RESISTANT WITH A CONTROLLED ACCESS.
7.DRY WELL SUMP PUMPS:
(A)A DRY WELL MUST USE DUAL SUMP PUMPS, EACH WITH A MINIMUM CAPACITY OF 1,000 GALLONS PER HOUR AND CAPABLE OF
HANDLING THE VOLUME OF LIQUID GENERATED DURING PEAK OPERATIONS.
(B)A PUMP MUST HAVE A SUBMERSIBLE MOTOR AND WATERTIGHT WIRING.
(C)A DRY WELL FLOOR MUST SLOPE TOWARD A SUMP SIZED FOR PROPER DRAINAGE.
(D)THE MINIMUM SUMP DEPTH IS 6.0 INCHES AND MUST PREVENT STANDING WATER ON A DRY WELL FLOOR UNDER NORMAL
OPERATION.
(E)A SUMP PUMP MUST OPERATE AUTOMATICALLY BY USE OF A FLOAT SWITCH OR OTHER LEVEL-DETECTING DEVICE.
(F)A SUMP PUMP MUST USE SEPARATE PIPES CAPABLE OF DISCHARGING MORE THAN THE MAXIMUM LIQUID LEVEL OF AN
ASSOCIATED WET WELL.
(G)A SUMP PUMP OUTLET PIPE MUST BE AT LEAST 1.5 INCHES IN DIAMETER AND HAVE AT LEAST TWO CHECK VALVES IN SERIES.
8.PUMP CONTROLS.
(A)A LIFT STATION PUMP MUST OPERATE AUTOMATICALLY, BASED ON THE WATER LEVEL IN A WET WELL.
(B)THE LOCATION OF A WET WELL LEVEL MECHANISM MUST ENSURE THAT THE MECHANISM IS UNAFFECTED BY CURRENTS, RAGS,
GREASE, OR OTHER FLOATING MATERIALS.
(C)A LEVEL MECHANISM MUST BE ACCESSIBLE WITHOUT ENTERING THE WET WELL.
(D)WET WELL CONTROLS WITH A BUBBLER SYSTEM REQUIRE DUAL AIR SUPPLY AND DUAL CONTROLS.
(E)MOTOR CONTROL CENTERS MUST BE MOUNTED AT LEAST 4.0 INCHES ABOVE GRADE TO PREVENT WATER INTRUSION AND
CORROSION FROM STANDING WATER IN THE ENCLOSURE.
(F)ELECTRICAL EQUIPMENT AND ELECTRICAL CONNECTIONS IN A WET WELL OR A DRY WELL MUST MEET NATIONAL FIRE PREVENTION
ASSOCIATION 70 NATIONAL ELECTRIC CODE EXPLOSION PREVENTION REQUIREMENTS, UNLESS CONTINUOUS VENTILATION IS
PROVIDED.
9.WET WELLS.
(A)A WET WELL MUST BE ENCLOSED BY WATERTIGHT AND GAS TIGHT WALLS.
(B)A PENETRATION THROUGH A WALL OF A WET WELL MUST BE GAS TIGHT.
(C)A WET WELL MUST NOT CONTAIN EQUIPMENT REQUIRING REGULAR OR ROUTINE INSPECTION OR MAINTENANCE, UNLESS
INSPECTION AND MAINTENANCE CAN BE DONE WITHOUT STAFF ENTERING THE WET WELL.
(D)A GRAVITY PIPE DISCHARGING TO A WET WELL MUST BE LOCATED SO THAT THE INVERT ELEVATION IS ABOVE THE LIQUID LEVEL
OF A PUMP'S "ON" SETTING.
(E)GATE VALVES AND CHECK VALVES ARE PROHIBITED IN A WET WELL.
(F)GATE VALVES AND CHECK VALVES MAY BE LOCATED IN A VALVE VAULT NEXT TO A WET WELL OR IN A DRY WELL.
(G)PUMP CYCLE TIME, BASED ON PEAK FLOW, MUST EQUAL OR EXCEED THOSE IN THE FOLLOWING TABLE:
PUMP HORSEPOWER MINIMUM CYCLE TIMES (MINUTES)
<50 6
50-100 10
> 100 15
(A)AN EVALUATION OF MINIMUM WET WELL VOLUME REQUIRES THE FOLLOWING FORMULA:
WHERE:
V = ACTIVE VOLUME (CUBIC FEET)
Q = PUMP CAPACITY (GALLONS PER MINUTE)
T = CYCLE TIME (MINUTES)
7.48 = CONVERSION FACTOR (GALLONS/CUBIC FOOT)
10.WET WELL SLOPES.
(A)A WET WELL FLOOR MUST HAVE A SMOOTH FINISH AND MINIMUM SLOPE OF 10% TO A PUMP INTAKE.
(B)A WET WELL DESIGN MUST PREVENT DEPOSITION OF SOLIDS UNDER NORMAL OPERATING CONDITIONS.
(C)A LIFT STATION WITH GREATER THAN 5.0 MILLION GALLONS PER DAY FIRM PUMPING CAPACITY MUST HAVE ANTI-VORTEX
BAFFLING.
11.DRY WELL ACCESS.
(A)AN UNDERGROUND DRY WELL MUST BE ACCESSIBLE.
(B)A STAIRWAY IN A DRY WELL MUST USE NON-SLIP STEPS AND CONFORM TO OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION
REGULATIONS WITH RESPECT TO RISE AND RUN.
(C)A LADDER IN A DRY WELL MUST MADE OF NON-CONDUCTIVE MATERIAL AND RATED FOR THE LOAD NECESSARY FOR STAFF AND
EQUIPMENT TO DESCEND AND ASCEND.
12.VENTILATION SHALL BE PROVIDED FOR LIFT STATIONS, INCLUDING BOTH WET AND DRY WELLS.
13.HOISTING EQUIPMENT. A LIFT STATION MUST HAVE PERMANENT HOISTING EQUIPMENT OR BE ACCESSIBLE TO PORTABLE HOISTING
EQUIPMENT FOR REMOVAL OF PUMPS, MOTORS, VALVES, PIPES, AND OTHER SIMILAR EQUIPMENT.
14.A FLOOR DRAIN FROM A VALVE VAULT TO A WET WELL MUST PREVENT GAS FROM ENTERING A VALVE VAULT BY INCLUDING FLAP
VALVES, "P" TRAPS, SUBMERGED OUTLETS, OR A COMBINATION OF THESE DEVICES.
15.PUMPS.
(A)GENERAL REQUIREMENTS. A RAW WASTEWATER PUMP, WITH THE EXCEPTION OF A GRINDER PUMP, MUST:
(1)BE DESIGNED TO PREVENT CLOGGING;
(2)BE CAPABLE OF PASSING A SPHERE OF 2.5 INCHES IN DIAMETER OR GREATER; AND
(3)HAVE GREATER THAN 3.0 INCH DIAMETER SUCTION AND DISCHARGE OPENINGS.
(B)SUBMERSIBLE AND NON-SUBMERSIBLE PUMPS.
(1)A NON-SUBMERSIBLE PUMP MUST HAVE INSPECTION AND CLEANOUT PLATES ON BOTH THE SUCTION AND DISCHARGE SIDES OF
EACH PUMPING UNIT THAT FACILITATE LOCATING AND REMOVING BLOCKAGE-CAUSING MATERIALS, UNLESS THE PUMP DESIGN
ACCOMMODATES EASY REMOVAL OF THE ROTATION ELEMENTS.
(2)A PUMP SUPPORT MUST PREVENT MOVEMENT AND VIBRATION DURING OPERATION.
(3)A SUBMERSIBLE PUMP MUST USE A RAIL-TYPE PUMP SUPPORT SYSTEM WITH MANUFACTURER-APPROVED MECHANISMS
DESIGNED TO ALLOW PERSONNEL TO REMOVE AND REPLACE ANY SINGLE PUMP WITHOUT ENTERING OR DEWATERING THE WET
WELL.
(4)SUBMERSIBLE PUMP RAILS AND LIFTING CHAINS MUST BE CONSTRUCTED OF A MATERIAL THAT PERFORMS TO AT LEAST THE
STANDARD OF SERIES 300 STAINLESS STEEL.
(C)LIFT STATION PUMPING CAPACITY. THE FIRM PUMPING CAPACITY OF A LIFT STATION MUST HANDLE THE EXPECTED PEAK FLOW.
(D)PUMP HEAD CALCULATIONS.
(1)AN OWNER SHALL SELECT A PUMP BASED UPON ANALYSIS OF THE SYSTEM HEAD AND PUMP CAPACITY CURVES THAT DETERMINE
THE PUMPING CAPACITIES ALONE AND WITH OTHER PUMPS AS THE TOTAL DYNAMIC-HEAD INCREASES DUE TO ADDITIONAL FLOWS
PUMPED THROUGH A FORCE MAIN.
(2)THE PIPE HEAD LOSS CALCULATIONS, USING THE HYDRAULIC INSTITUTE STANDARDS, PERTAINING TO HEAD LOSSES THROUGH
PIPES, VALVES, AND FITTINGS, MUST BE INCLUDED IN THE REPORT.
(3)THE SELECTED FRICTION COEFFICIENT (HAZEN-WILLIAMS "C" VALUE) USED IN FRICTION HEAD LOSS CALCULATIONS MUST BE
BASED ON THE PIPE MATERIAL SELECTED.
(4)FOR A LIFT STATION WITH MORE THAN TWO PUMPS, A FORCE MAIN IN EXCESS OF ONE-HALF MILE, OR FIRM PUMPING CAPACITY OF
100 GALLONS PER MINUTE OR GREATER, SYSTEM CURVES MUST BE PROVIDED FOR BOTH THE NORMAL AND PEAK OPERATING
CONDITIONS AT C VALUES FOR PROPOSED AND EXISTING PIPE.
(E)FLOW CONTROL.
(1)A LIFT STATION OR A TRANSFER PUMPING STATION LOCATED AT OR DISCHARGING DIRECTLY TO A WASTEWATER TREATMENT
SYSTEM MUST HAVE A PEAK PUMP CAPACITY EQUAL TO OR LESS THAN THE PEAK DESIGN FLOW, UNLESS EQUALIZATION IS
PROVIDED.
(2)A WASTEWATER TREATMENT SYSTEM WITH A PEAK FLOW THAT IS GREATER THAN 300,000 GALLON PER DAY MUST USE THREE
OR MORE PUMPS, UNLESS DUPLEX, AUTOMATICALLY CONTROLLED, VARIABLE CAPACITY PUMPS ARE PROVIDED.
(F)SELF-PRIMING PUMPS.
(1)A SELF-PRIMING PUMP MUST BE CAPABLE OF PRIMING WITHOUT RELIANCE UPON A SEPARATE PRIMING SYSTEM, AN INTERNAL
FLAP VALVE, OR ANY EXTERNAL MEANS FOR PRIMING.
(2)A SELF-PRIMING PUMP MUST USE A SUCTION PIPE VELOCITY AT LEAST 3.0 FEET PER SECOND BUT NOT MORE THAN 7.0 FEET PER
SECOND, AND MUST INCORPORATE ITS OWN SUCTION PIPE.
(3)A SELF-PRIMING PUMP MUST VENT AIR BACK INTO THE WET WELL DURING PRIMING.
(G)VACUUM-PRIMING PUMPS.
(1)A VACUUM-PRIMED PUMP MUST BE CAPABLE OF PRIMING BY USING A SEPARATE POSITIVE PRIMING SYSTEM WITH A DEDICATED
VACUUM PUMP FOR EACH MAIN WASTEWATER PUMP.
(2)A VACUUM-PRIMING PUMP MUST USE A SUCTION PIPE VELOCITY AT LEAST 3.0 FEET PER SECOND BUT LESS THAN 7.0 FEET PER
SECOND AND MUST HAVE ITS OWN SUCTION PIPE.
(H)VERTICAL POSITIONING OF PUMPS. A RAW WASTEWATER PUMP MUST HAVE POSITIVE STATIC SUCTION HEAD DURING NORMAL
ON-OFF CYCLING, EXCEPT A SUBMERSIBLE PUMP WITH "NO SUCTION" PIPES, A VACUUM-PRIMED PUMP, OR A SELF-PRIMING UNIT
CAPABLE OF SATISFACTORY OPERATION UNDER ANY NEGATIVE SUCTION HEAD ANTICIPATED FOR THE LIFT STATION.
(I)INDIVIDUAL GRINDER PUMPS. A GRINDER PUMP SERVING ONLY ONE RESIDENTIAL OR COMMERCIAL STRUCTURE THAT IS
PRIVATELY OWNED, MAINTAINED, AND OPERATED IS NOT SUBJECT TO THE RULES OF THIS CHAPTER.
(J)PUMP FOR LOW-FLOW LIFT STATION. A PUMP USED FOR A LIFT STATION WITH A PEAK FLOW OF LESS THAN 120 GALLONS PER
MINUTE MUST BE SUBMERSIBLE AND INCLUDE A GRINDER.
16.PIPING.
(A)HORIZONTAL PUMP SUCTIONS.
(1)EACH PUMP MUST HAVE A SEPARATE SUCTION PIPE THAT USES AN ECCENTRIC REDUCER.
(2)PIPES IN A WET WELL MUST HAVE A TURNDOWN TYPE FLARED INTAKE.
(B)VALVES.
(1)THE DISCHARGE SIDE OF EACH PUMP FOLLOWED BY A FULL-CLOSING ISOLATION VALVE MUST ALSO HAVE A CHECK VALVE.
(A)A CHECK VALVE MUST BE A SWING TYPE VALVE WITH AN EXTERNAL LEVER.
(B)A VALVE MUST INCLUDE A POSITION INDICATOR TO SHOW ITS OPEN AND CLOSED POSITIONS, UNLESS A FULL-CLOSING VALVE IS A
RISING-STEM GATE VALVE.
(2)A GRINDER PUMP INSTALLATION MAY USE A RUBBER-BALL CHECK VALVE OR A SWING-TYPE CHECK VALVE.
(3)A BUTTERFLY VALVE, TILTING-DISC CHECK VALVE, OR ANY OTHER VALVE USING A TILTING-DISC IN A FLOW PIPE IS PROHIBITED.
(C)PIPES.
(1)A LIFT STATION PIPE MUST HAVE FLANGED OR FLEXIBLE CONNECTIONS TO ALLOW FOR REMOVAL OF PUMPS AND VALVES
WITHOUT INTERRUPTION OF THE LIFT STATION OPERATIONS.
(2)WALL PENETRATIONS MUST ALLOW FOR PIPE FLEXURE WHILE EXCLUDING EXFILTRATION OR INFILTRATION.
(3)PIPE SUCTION VELOCITIES MUST BE AT LEAST 3.0 FEET PER SECOND BUT NOT MORE THAN 7.0 FEET PER SECOND.
17.EMERGENCY PROVISIONS FOR LIFT STATIONS.
(A)A COLLECTION SYSTEM LIFT STATION MUST BE EQUIPPED WITH A TESTED QUICK-CONNECT MECHANISM OR A TRANSFER SWITCH
PROPERLY SIZED TO CONNECT TO A PORTABLE GENERATOR, IF NOT EQUIPPED WITH AN ONSITE GENERATOR.
(B)LIFT STATIONS MUST INCLUDE AN AUDIOVISUAL ALARM SYSTEM AND THE SYSTEM MUST TRANSMIT ALL ALARM CONDITIONS
THROUGH USE OF AN AUTO-DIALER SYSTEM, SUPERVISORY CONTROL AND DATA ACQUISITION SYSTEM, OR TELEMETERING
SYSTEM CONNECTED TO A CONTINUOUSLY MONITORED LOCATION.
(C)AN ALARM SYSTEM MUST SELF-ACTIVATE FOR A POWER OUTAGE, PUMP FAILURE, OR A HIGH WET WELL WATER LEVEL.
(D)A LIFT STATION CONSTRUCTED TO PUMP RAW WASTEWATER MUST HAVE SERVICE RELIABILITY BASED ON:
(1)RETENTION CAPACITY.
(A)THE RETENTION CAPACITY IN A LIFT STATION'S WET WELL AND INCOMING GRAVITY PIPES MUST PREVENT DISCHARGES OF
UNTREATED WASTEWATER AT THE LIFT STATION OR ANY POINT UPSTREAM FOR A PERIOD OF TIME EQUAL TO THE LONGEST
ELECTRICAL OUTAGE RECORDED DURING THE PAST 24 MONTHS, BUT NOT LESS THAN 20 MINUTES.
(B)FOR CALCULATION PURPOSES, THE OUTAGE PERIOD BEGINS WHEN A LIFT STATION PUMP FINISHED ITS LAST NORMAL CYCLE,
EXCLUDING A STANDBY PUMP.
(1)ON-SITE GENERATORS. A LIFT STATION MAY BE PROVIDED EMERGENCY POWER BY ON-SITE, AUTOMATIC ELECTRICAL
GENERATORS SIZED TO OPERATE THE LIFT STATION AT ITS FIRM PUMPING CAPACITY OR AT THE AVERAGE DAILY FLOW, IF THE
PEAK FLOW CAN BE STORED IN THE COLLECTION SYSTEM.
(2)PORTABLE GENERATORS AND PUMPS.
(A)A LIFT STATION MAY USE PORTABLE GENERATORS AND PUMPS TO GUARANTEE SERVICE IF THE REPORT INCLUDES:
(3)THE STORAGE LOCATION OF EACH GENERATOR AND PUMP;
(4)THE AMOUNT OF TIME THAT WILL BE NEEDED TO TRANSPORT EACH GENERATOR OR PUMP TO A LIFT STATION;
(5)THE NUMBER OF LIFT STATIONS FOR WHICH EACH GENERATOR OR PUMP IS DEDICATED AS A BACKUP; AND
(6)THE TYPE OF ROUTINE MAINTENANCE AND UPKEEP PLANNED FOR EACH PORTABLE GENERATOR AND PUMP TO ENSURE THAT
THEY WILL BE OPERATIONAL WHEN NEEDED.
(B)AN OPERATOR THAT IS KNOWLEDGEABLE IN OPERATION OF THE PORTABLE GENERATORS AND PUMPS SHALL BE ON CALL 24
HOURS PER DAY EVERY DAY.
(C)THE SIZE OF A PORTABLE GENERATOR MUST HANDLE THE FIRM PUMPING CAPACITY OF THE LIFT STATION.
(E)SPILL CONTAINMENT STRUCTURES.
(1)THE USE OF A SPILL CONTAINMENT STRUCTURE AS A SOLE MEANS OF PROVIDING SERVICE RELIABILITY IS PROHIBITED.
(2)A LIFT STATION MAY USE A SPILL CONTAINMENT STRUCTURE IN ADDITION TO ONE OF THE SERVICE RELIABILITY OPTIONS
DETAILED IN THIS IN SUBSECTION (A) OF THIS SECTION.
(3)THE REPORT MUST INCLUDE A DETAILED MANAGEMENT PLAN FOR CLEANING AND MAINTAINING EACH SPILL CONTAINMENT
STRUCTURE.
(4)A SPILL CONTAINMENT STRUCTURE MUST HAVE A LOCKED GATE AND BE SURROUNDED AN INTRUDER RESISTANT FENCE THAT IS
6.0 FEET HIGH CHAIN LINK, MASONRY, OR BOARD FENCE WITH AT LEAST THREE STRANDS OF BARBED WIRE OR 8.0 FEET HIGH
CHAIN LINK, MASONRY, OR BOARD FENCE WITH AT LEAST ONE STRAND OF BARBED WIRE.
(F)A LIFT STATION MUST BE FULLY ACCESSIBLE DURING A 25-YEAR 24-HOUR RAINFALL EVENT.
(G)LIFT STATION SYSTEM CONTROLS MUST PREVENT OVER-PUMPING UPON RESUMPTION OF NORMAL POWER AFTER A POWER
FAILURE. BACKUP OR STANDBY UNITS MUST BE ELECTRICALLY INTERLOCKED TO PREVENT OPERATION AT THE SAME TIME THAT
OTHER LIFT STATIONS PUMPS ARE OPERATING ONLY ON THE RESUMPTION OF NORMAL POWER AFTER A POWER FAILURE.
36
GN-2
DK
PND
PND
TC
E
Q
G
E
N
E
R
A
L
N
O
T
E
S
1
O
F
2
IH
-
3
5
R
I
A
T
A
L
I
F
T
S
T
A
T
I
O
N
R
E
L
O
C
A
T
I
O
N
A
N
D
OF
F
S
I
T
E
S
E
W
E
R
I
M
P
R
O
V
E
M
E
N
T
S
8032-03
30 January, 2023
UT
I
L
I
T
Y
EN
G
I
N
E
E
R
I
N
G
GR
O
U
P
PL
L
C
Te
x
a
s
E
n
g
i
n
e
e
r
i
n
g
F
i
r
m
F
-
1
8
7
1
2
19
1
N
.
U
n
i
o
n
A
v
e
N
E
W
B
R
A
U
N
F
E
L
S
,
T
E
X
A
S
7
8
1
3
0
P
H
:
(
8
3
0
)
2
1
4
-
0
5
2
1
UEG
TEXAS COMMISSION ON ENVIRONMENTAL QUALITY
ORGANIZED SEWAGE COLLECTION SYSTEM (SCS)
GENERAL CONSTRUCTION NOTES
1.THIS ORGANIZED SEWAGE COLLECTION SYSTEM MUST BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE TEXAS
COMMISSION ON ENVIRONMENTAL QUALITY'S (TCEQ) EDWARDS AQUIFER RULES 30 TEXAS ADMINISTRATIVE CODE (TAC) §§213.5(C) AND
217.51 - 217.70 AND 30 TAC CHAPTER 217, SUBCHAPTER D, AND THE CITY OF SCHERTZ STANDARD SPECIFICATIONS.
2.ALL CONTRACTORS CONDUCTING REGULATED ACTIVITIES ASSOCIATED WITH THIS PROPOSED REGULATED PROJECT MUST BE
PROVIDED WITH COPIES OF THE SEWAGE COLLECTION SYSTEM PLAN AND THE TCEQ LETTER INDICATING THE SPECIFIC CONDITIONS OF
ITS APPROVAL. DURING THE COURSE OF THESE REGULATED ACTIVITIES, THE CONTRACTORS MUST BE REQUIRED TO KEEP ON-SITE
COPIES OF THE PLAN AND THE APPROVAL LETTER.
3.NO LATER THAN 48 HOURS PRIOR TO COMMENCING ANY REGULATED ACTIVITY, THE APPLICANT OR HIS AGENT MUST NOTIFY THE
REGIONAL OFFICE, IN WRITING, OF THE DATE ON WHICH THE REGULATED ACTIVITY WILL BEGIN.
4.ANY MODIFICATION TO THE ACTIVITIES DESCRIBED IN THE REFERENCED SCS APPLICATION FOLLOWING THE DATE OF APPROVAL MAY
REQUIRE THE SUBMITTAL OF AN SCS APPLICATION TO MODIFY THIS APPROVAL, INCLUDING THE PAYMENT OF APPROPRIATE FEES AND
ALL INFORMATION NECESSARY FOR ITS REVIEW AND APPROVAL.
5.ALL TEMPORARY EROSION AND SEDIMENTATION CONTROLS MUST BE INSTALLED PRIOR TO CONSTRUCTION, MUST BE MAINTAINED
DURING CONSTRUCTION, AND MUST BE REMOVED WHEN SUFFICIENT VEGETATION IS ESTABLISHED TO CONTROL THE EROSION AND
SEDIMENTATION AND THE CONSTRUCTION AREA IS STABILIZED.
6.THE SEWER LINE TRENCH DETAILS SHOWING THE CROSS SECTION WITH THE DIMENSIONS, PIPE PLACEMENT, AND BACKFILL
INSTRUCTIONS. ALL SEWER PIPES JOINTS MUST MEET THE REQUIREMENTS IN 30 TAC §§217.53(C) AND 217.65.
GRAVITY LINES MUST HAVE A SDR 35 OR LESS. PRESSURIZED SEWER SYSTEMS MUST HAVE PIPE WITH A MINIMUM WORKING PRESSURE
RATING OF 150 PSI.
THE ASTM, ANSI, OR AWWA SPECIFICATION NUMBERS FOR THE PIPE(S) AND JOINTS ARE ASTM F679 PS115 & ASTM D3034 SDR26.
THE PIPE MATERIAL, THE PRESSURE CLASSES, AND THE SDR AND/OR DR DESIGNATIONS ARE SDR-26.
7.IF ANY SENSITIVE FEATURES ARE DISCOVERED DURING THE WASTEWATER LINE TRENCHING ACTIVITIES, ALL REGULATED ACTIVITIES
NEAR THE SENSITIVE FEATURE MUST BE SUSPENDED IMMEDIATELY. THE APPLICANT MUST IMMEDIATELY NOTIFY THE APPROPRIATE
REGIONAL OFFICE OF THE TEXAS COMMISSION ON ENVIRONMENTAL QUALITY OF THE FEATURE DISCOVERED. A GEOLOGIST'S
ASSESSMENT OF THE LOCATION AND EXTENT OF THE FEATURE DISCOVERED MUST BE REPORTED TO THAT REGIONAL OFFICE IN
WRITING WITHIN TWO WORKING DAYS. THE APPLICANT MUST SUBMIT A PLAN FOR ENSURING THE STRUCTURAL INTEGRITY OF THE
SEWER LINE OR FOR MODIFYING THE PROPOSED COLLECTION SYSTEM ALIGNMENT AROUND THE FEATURE. THE REGULATED
ACTIVITIES NEAR THE SENSITIVE FEATURE MAY NOT PROCEED UNTIL THE EXECUTIVE DIRECTOR HAS REVIEWED AND APPROVED THE
METHODS PROPOSED TO PROTECT THE SENSITIVE FEATURE AND THE EDWARDS AQUIFER FROM ANY POTENTIALLY ADVERSE IMPACTS
TO WATER QUALITY WHILE MAINTAINING THE STRUCTURAL INTEGRITY OF THE LINE.
8.SEWER LINES LOCATED WITHIN OR CROSSING THE 5-YEAR FLOODPLAIN OF A DRAINAGE WAY WILL BE PROTECTED FROM INUNDATION
AND STREAM VELOCITIES WHICH COULD CAUSE EROSION AND SCOURING OF BACKFILL. THE TRENCH MUST BE CAPPED WITH
CONCRETE TO PREVENT SCOURING OF BACKFILL, OR THE SEWER LINES MUST BE ENCASED IN CONCRETE. ALL CONCRETE SHALL HAVE
A MINIMUM THICKNESS OF SIX (6) INCHES.
9.BLASTING PROCEDURES FOR PROTECTION OF EXISTING SEWER LINES AND OTHER UTILITIES WILL BE IN ACCORDANCE WITH THE
NATIONAL FIRE PROTECTION ASSOCIATION CRITERIA. SAND IS NOT ALLOWED AS BEDDING OR BACKFILL IN TRENCHES THAT HAVE BEEN
BLASTED. IF ANY EXISTING SEWER LINES ARE DAMAGED, THE LINES MUST BE REPAIRED AND RETESTED.
10.ALL MANHOLES CONSTRUCTED OR REHABILITATED ON THIS PROJECT MUST HAVE WATERTIGHT SIZE ON SIZE RESILIENT CONNECTORS
ALLOWING FOR DIFFERENTIAL SETTLEMENT. IF MANHOLES ARE CONSTRUCTED WITHIN THE 100-YEAR FLOODPLAIN, THE COVER MUST
HAVE A GASKET AND BE BOLTED TO THE RING. WHERE GASKETED MANHOLE COVERS ARE REQUIRED FOR MORE THAN THREE
MANHOLES IN SEQUENCE OR FOR MORE THAN 1500 FEET, ALTERNATE MEANS OF VENTING WILL BE PROVIDED. BRICKS ARE NOT AN
ACCEPTABLE CONSTRUCTION MATERIAL FOR ANY PORTION OF THE MANHOLE.
THE DIAMETER OF THE MANHOLES MUST BE A MINIMUM OF FOUR FEET AND THE MANHOLE FOR ENTRY MUST HAVE A MINIMUM CLEAR
OPENING DIAMETER OF 30 INCHES. THESE DIMENSIONS AND OTHER DETAILS SHOWING COMPLIANCE WITH THE COMMISSION'S RULES
CONCERNING MANHOLES AND SEWER LINE/MANHOLE INVERTS DESCRIBED IN 30 TAC §217.55.
IT IS SUGGESTED THAT ENTRANCE INTO MANHOLES IN EXCESS OF FOUR FEET DEEP BE ACCOMPLISHED BY MEANS OF A PORTABLE
LADDER. THE INCLUSION OF STEPS IN A MANHOLE IS PROHIBITED.
11.WHERE WATER LINES AND NEW SEWER LINE ARE INSTALLED WITH A SEPARATION DISTANCE CLOSER THAN NINE FEET (I.E., WATER
LINES CROSSING WASTEWATER LINES, WATER LINES PARALLELING WASTEWATER LINES, OR WATER LINES NEXT TO MANHOLES) THE
INSTALLATION MUST MEET THE REQUIREMENTS OF 30 TAC §217.53(D) (PIPE DESIGN) AND 30 TAC §290.44(E) (WATER DISTRIBUTION).
12.WHERE SEWERS LINES DEVIATE FROM STRAIGHT ALIGNMENT AND UNIFORM GRADE ALL CURVATURE OF SEWER PIPE MUST BE
ACHIEVED BY THE FOLLOWING PROCEDURE WHICH IS RECOMMENDED BY THE PIPE MANUFACTURER: NOT ALLOWED.
IF PIPE FLEXURE IS PROPOSED, THE FOLLOWING METHOD OF PREVENTING DEFLECTION OF THE JOINT MUST BE USED: NOT ALLOWED.
SPECIFIC CARE MUST BE TAKEN TO ENSURE THAT THE JOINT IS PLACED IN THE CENTER OF THE TRENCH AND PROPERLY BEDDED IN
ACCORDANCE WITH 30 TAC §217.54.
13.NEW SEWAGE COLLECTION SYSTEM LINES MUST BE CONSTRUCTED WITH STUB OUTS FOR THE CONNECTION OF ANTICIPATED
EXTENSIONS. THE LOCATION OF SUCH STUB OUTS MUST BE MARKED ON THE GROUND SUCH THAT THEIR LOCATION CAN BE EASILY
DETERMINED AT THE TIME OF CONNECTION OF THE EXTENSIONS. SUCH STUB OUTS MUST BE MANUFACTURED WYES OR TEES THAT
ARE COMPATIBLE IN SIZE AND MATERIAL WITH BOTH THE SEWER LINE AND THE EXTENSION. AT THE TIME OF ORIGINAL CONSTRUCTION,
NEW STUB-OUTS MUST BE CONSTRUCTED SUFFICIENTLY TO EXTEND BEYOND THE END OF THE STREET PAVEMENT. ALL STUB-OUTS
MUST BE SEALED WITH A MANUFACTURED CAP TO PREVENT LEAKAGE. EXTENSIONS THAT WERE NOT ANTICIPATED AT THE TIME OF
ORIGINAL CONSTRUCTION OR THAT ARE TO BE CONNECTED TO AN EXISTING SEWER LINE NOT FURNISHED WITH STUB OUTS MUST BE
CONNECTED USING A MANUFACTURED SADDLE AND IN ACCORDANCE WITH ACCEPTED PLUMBING TECHNIQUES.
THE PRIVATE SERVICE LATERAL STUB-OUTS MUST BE INSTALLED AS SHOWN ON THE PLAN AND PROFILE SHEETS AND MARKED AFTER
BACKFILLING.
TRENCHING, BEDDING AND BACKFILL MUST CONFORM WITH 30 TAC §217.54. THE BEDDING AND BACKFILL FOR FLEXIBLE PIPE MUST COMPLY
WITH THE STANDARDS OF ASTM D-2321, CLASSES IA, IB, II OR III. RIGID PIPE BEDDING MUST COMPLY WITH THE REQUIREMENTS OF ASTM
C 12 (ANSI A 106.2) CLASSES A, B OR C.
14.SEWER LINES MUST BE TESTED FROM MANHOLE TO MANHOLE. WHEN A NEW SEWER LINE IS CONNECTED TO AN EXISTING STUB OR
CLEAN-OUT, IT MUST BE TESTED FROM EXISTING MANHOLE TO NEW MANHOLE. IF A STUB OR CLEAN-OUT IS USED AT THE END OF THE
PROPOSED SEWER LINE, NO PRIVATE SERVICE ATTACHMENTS MAY BE CONNECTED BETWEEN THE LAST MANHOLE AND THE CLEANOUT
UNLESS IT CAN BE CERTIFIED AS CONFORMING WITH THE PROVISIONS OF 30 TAC §213.5(C)(3)(E).
15.
16.ALL SEWER LINES MUST BE TESTED IN ACCORDANCE WITH 30 TAC §217.57. THE ENGINEER MUST RETAIN COPIES OF ALL TEST RESULTS
WHICH MUST BE MADE AVAILABLE TO THE EXECUTIVE DIRECTOR UPON REQUEST. THE ENGINEER MUST CERTIFY IN WRITING THAT ALL
WASTEWATER LINES HAVE PASSED ALL REQUIRED TESTING TO THE APPROPRIATE REGIONAL OFFICE WITHIN 30 DAYS OF TEST
COMPLETION AND PRIOR TO USE OF THE NEW COLLECTION SYSTEM. TESTING METHOD WILL BE:
(a)FOR A COLLECTION SYSTEM PIPE THAT WILL TRANSPORT WASTEWATER BY GRAVITY FLOW, THE DESIGN MUST SPECIFY AN INFILTRATION AND
EXFILTRATION TEST OR A LOW-PRESSURE AIR TEST. A TEST MUST CONFORM TO THE FOLLOWING REQUIREMENTS:
1.LOW PRESSURE AIR TEST.
A.A LOW PRESSURE AIR TEST MUST FOLLOW THE PROCEDURES DESCRIBED IN AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) C-828,
ASTM C-924, OR ASTM F-1417 OR OTHER PROCEDURE APPROVED BY THE EXECUTIVE DIRECTOR, EXCEPT AS TO TESTING TIMES AS REQUIRED
IN TABLE C.3 IN SUBPARAGRAPH (C) OF THIS PARAGRAPH OR EQUATION C.3 IN SUBPARAGRAPH (B)(II) OF THIS PARAGRAPH.
B.FOR SECTIONS OF COLLECTION SYSTEM PIPE LESS THAN 36 INCH AVERAGE INSIDE DIAMETER, THE FOLLOWING PROCEDURE MUST APPLY,
UNLESS A PIPE IS TO BE TESTED AS REQUIRED BY PARAGRAPH (2) OF THIS SUBSECTION.
(i) A PIPE MUST BE PRESSURIZED TO 3.5 POUNDS PER SQUARE INCH (PSI) GREATER THAN THE PRESSURE EXERTED BY GROUNDWATER
ABOVE THE PIPE.
(ii) ONCE THE PRESSURE IS STABILIZED, THE MINIMUM TIME ALLOWABLE FOR THE PRESSURE TO DROP FROM 3.5 PSI GAUGE TO 2.5 PSI GAUGE
IS COMPUTED FROM THE FOLLOWING EQUATION:
EQUATION C.3
WHERE:
T =TIME FOR PRESSURE TO DROP 1.0 POUND PER SQUARE INCH GAUGE IN SECONDS
K =0.000419 X D X L, BUT NOT LESS THAN 1.0
D =AVERAGE INSIDE PIPE DIAMETER IN INCHES
L =LENGTH OF LINE OF SAME SIZE BEING TESTED, IN FEET
Q =RATE OF LOSS, 0.0015 CUBIC FEET PER MINUTE PER SQUARE FOOT INTERNAL SURFACE
(C) SINCE A K VALUE OF LESS THAN 1.0 MAY NOT BE USED, THE MINIMUM TESTING TIME FOR EACH PIPE DIAMETER IS SHOWN IN THE
FOLLOWING TABLE C.3:
(D)AN OWNER MAY STOP A TEST IF NO PRESSURE LOSS HAS OCCURRED DURING THE FIRST 25% OF THE CALCULATED TESTING
TIME.
(E)IF ANY PRESSURE LOSS OR LEAKAGE HAS OCCURRED DURING THE FIRST 25% OF A TESTING PERIOD, THEN THE TEST MUST
CONTINUE FOR THE ENTIRE TEST DURATION AS OUTLINED ABOVE OR UNTIL FAILURE.
(F)WASTEWATER COLLECTION SYSTEM PIPES WITH A 27 INCH OR LARGER AVERAGE INSIDE DIAMETER MAY BE AIR TESTED AT EACH
JOINT INSTEAD OF FOLLOWING THE PROCEDURE OUTLINED IN THIS SECTION.
(G)A TESTING PROCEDURE FOR PIPE WITH AN INSIDE DIAMETER GREATER THAN 33 INCHES MUST BE APPROVED BY THE EXECUTIVE
DIRECTOR.
(2)INFILTRATION/EXFILTRATION TEST.
(A)THE TOTAL EXFILTRATION, AS DETERMINED BY A HYDROSTATIC HEAD TEST, MUST NOT EXCEED 50 GALLONS PER INCH OF
DIAMETER PER MILE OF PIPE PER 24 HOURS AT A MINIMUM TEST HEAD OF 2.0 FEET ABOVE THE CROWN OF A PIPE AT AN
UPSTREAM MANHOLE.
(B)AN OWNER SHALL USE AN INFILTRATION TEST IN LIEU OF AN EXFILTRATION TEST WHEN PIPES ARE INSTALLED BELOW THE
GROUNDWATER LEVEL.
(C)THE TOTAL EXFILTRATION, AS DETERMINED BY A HYDROSTATIC HEAD TEST, MUST NOT EXCEED 50 GALLONS PER INCH DIAMETER
PER MILE OF PIPE PER 24 HOURS AT A MINIMUM TEST HEAD OF TWO FEET ABOVE THE CROWN OF A PIPE AT AN UPSTREAM
MANHOLE, OR AT LEAST TWO FEET ABOVE EXISTING GROUNDWATER LEVEL, WHICHEVER IS GREATER.
(D)FOR CONSTRUCTION WITHIN A 25-YEAR FLOOD PLAIN, THE INFILTRATION OR EXFILTRATION MUST NOT EXCEED 10 GALLONS PER
INCH DIAMETER PER MILE OF PIPE PER 24 HOURS AT THE SAME MINIMUM TEST HEAD AS IN SUBPARGRAPH (C) OF THIS
PARAGRAPH.
(E)IF THE QUANTITY OF INFILTRATION OR EXFILTRATION EXCEEDS THE MAXIMUM QUANTITY SPECIFIED, AN OWNER SHALL
UNDERTAKE REMEDIAL ACTION IN ORDER TO REDUCE THE INFILTRATION OR EXFILTRATION TO AN AMOUNT WITHIN THE LIMITS
SPECIFIED. AN OWNER SHALL RETEST A PIPE FOLLOWING A REMEDIATION ACTION.
(b)IF A GRAVITY COLLECTION PIPE IS COMPOSED OF FLEXIBLE PIPE, DEFLECTION TESTING IS ALSO REQUIRED. THE FOLLOWING
PROCEDURES MUST BE FOLLOWED:
(1)FOR A COLLECTION PIPE WITH INSIDE DIAMETER LESS THAN 27 INCHES, DEFLECTION MEASUREMENT REQUIRES A RIGID MANDREL.
(A)MANDREL SIZING.
(i)A RIGID MANDREL MUST HAVE AN OUTSIDE DIAMETER (OD) NOT LESS THAN 95% OF THE BASE INSIDE DIAMETER (ID) OR AVERAGE ID OF
A PIPE, AS SPECIFIED IN THE APPROPRIATE STANDARD BY THE ASTMS, AMERICAN WATER WORKS ASSOCIATION, UNI-BELL, OR
AMERICAN NATIONAL STANDARDS INSTITUTE, OR ANY RELATED APPENDIX.
(ii)IF A MANDREL SIZING DIAMETER IS NOT SPECIFIED IN THE APPROPRIATE STANDARD, THE MANDREL MUST HAVE AN OD EQUAL TO 95%
OF THE ID OF A PIPE. IN THIS CASE, THE ID OF THE PIPE, FOR THE PURPOSE OF DETERMINING THE OD OF THE MANDREL, MUST EQUAL
BE THE AVERAGE OUTSIDE DIAMETER MINUS TWO MINIMUM WALL THICKNESSES FOR OD CONTROLLED PIPE AND THE AVERAGE INSIDE
DIAMETER FOR ID CONTROLLED PIPE.
(iii)ALL DIMENSIONS MUST MEET THE APPROPRIATE STANDARD.
(B)MANDREL DESIGN.
(i)A RIGID MANDREL MUST BE CONSTRUCTED OF A METAL OR A RIGID PLASTIC MATERIAL THAT CAN WITHSTAND 200 PSI WITHOUT BEING
DEFORMED.
(ii)A MANDREL MUST HAVE NINE OR MORE ODD NUMBER OF RUNNERS OR LEGS.
(iii)A BARREL SECTION LENGTH MUST EQUAL AT LEAST 75% OF THE INSIDE DIAMETER OF A PIPE.
(iv)EACH SIZE MANDREL MUST USE A SEPARATE PROVING RING.
(C)METHOD OPTIONS.
(i)AN ADJUSTABLE OR FLEXIBLE MANDREL IS PROHIBITED.
(ii)A TEST MAY NOT USE TELEVISION INSPECTION AS A SUBSTITUTE FOR A DEFLECTION TEST.
(iii)IF REQUESTED, THE EXECUTIVE DIRECTOR MAY APPROVE THE USE OF A DEFLECTOMETER OR A MANDREL WITH REMOVABLE LEGS OR
RUNNERS ON A CASE-BY-CASE BASIS.
(2)FOR A GRAVITY COLLECTION SYSTEM PIPE WITH AN INSIDE DIAMETER 27 INCHES AND GREATER, OTHER TEST METHODS MAY BE
USED TO DETERMINE VERTICAL DEFLECTION.
(3)A DEFLECTION TEST METHOD MUST BE ACCURATE TO WITHIN PLUS OR MINUS 0.2% DEFLECTION.
(4)AN OWNER SHALL NOT CONDUCT A DEFLECTION TEST UNTIL AT LEAST 30 DAYS AFTER THE FINAL BACKFILL.
(5)GRAVITY COLLECTION SYSTEM PIPE DEFLECTION MUST NOT EXCEED FIVE PERCENT (5%)
(6)IF A PIPE SECTION FAILS A DEFLECTION TEST, AN OWNER SHALL CORRECT THE PROBLEM AND CONDUCT A SECOND TEST AFTER
THE FINAL BACKFILL HAS BEEN IN PLACE AT LEAST 30 DAYS.
18.ALL MANHOLES MUST BE TESTED TO MEET OR EXCEED THE REQUIREMENTS OF 30 TAC §217.58.
(a)ALL MANHOLES MUST PASS A LEAKAGE TEST.
(b)AN OWNER SHALL TEST EACH MANHOLE (AFTER ASSEMBLY AND BACKFILLING) FOR LEAKAGE, SEPARATE AND INDEPENDENT OF THE
COLLECTION SYSTEM PIPES, BY HYDROSTATIC EXFILTRATION TESTING, VACUUM TESTING, OR OTHER METHOD APPROVED BY THE
EXECUTIVE DIRECTOR.
(1)HYDROSTATIC TESTING.
(A)THE MAXIMUM LEAKAGE FOR HYDROSTATIC TESTING OR ANY ALTERNATIVE TEST METHODS IS 0.025 GALLONS PER FOOT
DIAMETER PER FOOT OF MANHOLE DEPTH PER HOUR.
(B)TO PERFORM A HYDROSTATIC EXFILTRATION TEST, AN OWNER SHALL SEAL ALL WASTEWATER PIPES COMING INTO A MANHOLE
WITH AN INTERNAL PIPE PLUG, FILL THE MANHOLE WITH WATER, AND MAINTAIN THE TEST FOR AT LEAST ONE HOUR.
(C)A TEST FOR CONCRETE MANHOLES MAY USE A 24-HOUR WETTING PERIOD BEFORE TESTING TO ALLOW SATURATION OF THE
CONCRETE.
(2)VACUUM TESTING.
(A)TO PERFORM A VACUUM TEST, AN OWNER SHALL PLUG ALL LIFT HOLES AND EXTERIOR JOINTS WITH A NON-SHRINK GROUT AND
PLUG ALL PIPES ENTERING A MANHOLE.
(B)NO GROUT MUST BE PLACED IN HORIZONTAL JOINTS BEFORE TESTING.
(C)STUB-OUTS, MANHOLE BOOTS, AND PIPE PLUGS MUST BE SECURED TO PREVENT MOVEMENT WHILE A VACUUM IS DRAWN.
(D)AN OWNER SHALL USE A MINIMUM 60 INCH/LB TORQUE WRENCH TO TIGHTEN THE EXTERNAL CLAMPS THAT SECURE A TEST
COVER TO THE TOP OF A MANHOLE.
(E)A TEST HEAD MUST BE PLACED AT THE INSIDE OF THE TOP OF A CONE SECTION, AND THE SEAL INFLATED IN ACCORDANCE WITH
THE MANUFACTURER'S RECOMMENDATIONS.
(F)THERE MUST BE A VACUUM OF 10 INCHES OF MERCURY INSIDE A MANHOLE TO PERFORM A VALID TEST.
(G)A TEST DOES NOT BEGIN UNTIL AFTER THE VACUUM PUMP IS OFF.
(H)A MANHOLE PASSES THE TEST IF AFTER 2.0 MINUTES AND WITH ALL VALVES CLOSED, THE VACUUM IS AT LEAST 9.0 INCHES OF
MERCURY.
19.ALL PRIVATE SERVICE LATERALS MUST BE INSPECTED AND CERTIFIED IN ACCORDANCE WITH 30 TAC §213.5(C)(3)(I). AFTER
INSTALLATION OF AND, PRIOR TO COVERING AND CONNECTING A PRIVATE SERVICE LATERAL TO AN EXISTING ORGANIZED SEWAGE
COLLECTION SYSTEM, A TEXAS LICENSED PROFESSIONAL ENGINEER, TEXAS REGISTERED SANITARIAN, OR APPROPRIATE CITY
INSPECTOR MUST VISUALLY INSPECT THE PRIVATE SERVICE LATERAL AND THE CONNECTION TO THE SEWAGE COLLECTION SYSTEM,
AND CERTIFY THAT IT IS CONSTRUCTED IN CONFORMITY WITH THE APPLICABLE PROVISIONS OF THIS SECTION. THE OWNER OF THE
COLLECTION SYSTEM MUST MAINTAIN SUCH CERTIFICATIONS FOR FIVE YEARS AND FORWARD COPIES TO THE APPROPRIATE REGIONAL
OFFICE UPON REQUEST. CONNECTIONS MAY ONLY BE MADE TO AN APPROVED SEWAGE COLLECTION SYSTEM.
36
GN-3
DK
PND
PND
TC
E
Q
G
E
N
E
R
A
L
N
O
T
E
S
2
O
F
2
IH
-
3
5
R
I
A
T
A
L
I
F
T
S
T
A
T
I
O
N
R
E
L
O
C
A
T
I
O
N
A
N
D
OF
F
S
I
T
E
S
E
W
E
R
I
M
P
R
O
V
E
M
E
N
T
S
8032-03
30 January, 2023
Pipe Diameter
(inches)
Minimum Time
(seconds)
Maximum Length for
Minimum Time (feet)
Time for Longer
Length (seconds/foot)
6 340 398 0.855
8 454 298 1.520
10 567 239 2.374
12 680 199 3.419
15 850 159 5.342
18 1020 133 7.693
21 1190 114 10.471
24 1360 100 13.676
27 1530 88 17.309
30 1700 80 21.369
33 1870 72 25.856
6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL
PROPOSED 45'
UTILITY EASEMENT
WWWWWW
WW
WW
WW
TEMPORARY 20'
CONSTRUCTION EASEMENT
PROPOSED 5-FT
DIA. DOGHOUSE
MANHOLE A-1
(SEE SHEET LS-4)
EXISTING 6"
FORCE MAIN
(SEE NOTE 8)
PROPOSED 8"
OFF-SITE GRAVITY MAIN
(SEE SHEET LS-4)
PROPOSED 6"
OFF-SITE FORCE MAIN
(SEE SHEET LS-5)
EXISTING 6" GVSUD
WATER LINE
(CONTRACTOR TO
VERIFY LOCATION)
CUT AND CAP
EXISTING 8"
GRAVITY MAIN
(SEE NOTE 4)
CUT AND CAP
EXISTING 6"
FORCE MAIN
(SEE NOTE 8)
EXISTING 8"
GRAVITY MAIN
(SEE NOTE 4)
EXISTING 4-FT DIA. SEWER
MANHOLE TO BE
ABANDONED FOLLOWING
CONSTRUCTION AND
ACCEPTANCE OF NEW
LIFT STATION AND
OFF-SITE GRAVITY MAIN
AND FORCE MAIN
(SEE NOTE 7 AND DETAIL
SHEET LS-14)
EXISTING
ROCK WALL
EXISTING
WATER METER
EXISTING
GAS LINE
EXISTING BIKE
LANE SIGN
FUTURE
WATER LINE
EXISTING
LIGHTS
28 SY OF
CURB AND
PAVEMENT
REPAIR
19 SY OF
CURB AND
PAVEMENT
REPAIR
6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL
WW
EXISTING 6"
FORCE MAIN
(SEE NOTE 8)
EXISTING 5-FT DIA. SEWER
MANHOLE TO BE ABANDONED
FOLLOWING CONSTRUCTION
AND ACCEPTANCE OF NEW LIFT
STATION AND OFF-SITE
GRAVITY MAIN AND FORCE MAIN
(SEE NOTE 7 AND DETAIL SHEET
LS-14)
PROPOSED
TXDOT RIGHT
OF WAY
EXISTING
12-INCH
WATER LINE EXISTING
OVERHEAD
UTILITY
EXISTING CONTROL
PANEL TO BE REMOVED
AND DELIVERED TO THE
CITY OF SCHERTZ.
(SEE ELECTRICAL PLANS
FOR EXISTING LIFT
STATION ELECTRICAL
DEMO)
EXISTING
4-INCH
GAS LINE
EXISTING 14-FT CIRCULAR
FIBERGLASS WET WELL
AND VALVE VAULT TO BE
ABANDONED.
(SEE SHEET DM-2)
EXISTING 15'
GVSUD UTILITY
EASTMENT
EXISTING TXDOT
RIGHT OF WAY
EXISTING 6" GVSUD
WATER LINE
(CONTRACTOR TO
VERIFY LOCATION)
EXISTING CONCRETE
FENCE AND GATES TO
BE SALVAGED PER
CITY OF SCHERTZ
DISCRETION
6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL
WWWW
± 469 SY OF EXISTING
ASPHALT PAVEMENT TO BE
REMOVED AND COVERED
WITH COMPACTED TOP SOIL
TO GRADE AND REVEGETATED
CONTRACTOR TO SAW CUT
EXISTING ASPHALT
PAVEMENT TO PROPOSED
END CURB RETURN.
(SEE LS-3 FOR PROPOSED
CURB RETURN)
UT
I
L
I
T
Y
EN
G
I
N
E
E
R
I
N
G
GR
O
U
P
PL
L
C
Te
x
a
s
E
n
g
i
n
e
e
r
i
n
g
F
i
r
m
F
-
1
8
7
1
2
19
1
N
.
U
n
i
o
n
A
v
e
N
E
W
B
R
A
U
N
F
E
L
S
,
T
E
X
A
S
7
8
1
3
0
P
H
:
(
8
3
0
)
2
1
4
-
0
5
2
1
UEG
FA
I
R
L
A
W
N
A
V
E
N
U
E
EXISTING GRAVITY AND FORCE MAIN ABANDONMENT
EXISTING LIFT STATION SITE ABANDONMENT
36
DM-1
DK
PND
PND
DE
M
O
S
H
E
E
T
1
O
F
2
IH
-
3
5
R
I
A
T
A
L
I
F
T
S
T
A
T
I
O
N
R
E
L
O
C
A
T
I
O
N
A
N
D
OF
F
S
I
T
E
S
E
W
E
R
I
M
P
R
O
V
E
M
E
N
T
S
8032-03
30 January, 2023
EXISTING LIFT STATION DRIVEWAY/SITE PAVEMENT ABANDONMENT
SITE INFORMATION:
LIFT STATION NUMBER/NAME: IH-35 RIATA LIFT STATION
RELOCATION AND OFFSITE SEWER IMPROVEMENTS
LOCATED AT: IH-35 , SCHERTZ, TEXAS
LATITUDE: N29° 37' 22.24" LONGITUDE: W98° 14' 37.41"
LOCATED WITHIN 100-YR FLOODPLAIN?: NO
LOCATED WITHIN EDWARDS AQUIFER?: NO
PROPOSED BOLLARD
PROPOSED CHAINLINK FENCE
LEGEND
PROPOSED WASTEWATER LINE
EXISTING MANHOLE
PROPOSED LIGHTPOLE
EXISTING TO BE REHABBED
PROPOSED WATER SERVICE
NOTES:
1.EXISTING LIFT STATION TO CONTINUE OPERATION
UNTIL RELOCATION OF PROPOSED STATION HAS
BEEN COMPLETED, TESTED, AND ACCEPTED FOR
SERVICE OPERATIONS BY ENGINEER AND CITY OF
SCHERTZ. CONTRACTOR TO COORDINATE EXISTING
LIFT STATION DECOMMISSIONING WITH CITY AND
ENGINEER.
2.CONTRACTOR TO COORDINATE PROPOSED OFF-SITE
8" GRAVITY MAIN AND PROPOSED OFF-SITE 6"
FORCE MAIN MAIN CONNECTIONS WITH CITY OF
SCHERTZ.
3.CONTRACTOR TO PROVIDE A BY-PASS PUMPING
PLAN FOR THE PROJECT FOR APPROVAL BY
ENGINEER AND THE CITY OF SCHERTZ PRIOR TO
CONSTRUCTION.
4.CONTRACTOR TO CUT, CAP AND ABANDON THE
EXISTING 8" GRAVITY MAIN PER CITY OF SCHERTZ
STANDARDS. CONTRACTOR TO COORDINATE
ABANDONMENT WITH CITY AND ENGINEER.
5.ALL EXISTING LIFT STATION PUMPS, VALVES,
APPURTENANCES, FENCING, CONTROL PANELS,
WIRING, ETC. TO BE REMOVED AND SALVAGED PER
CITY OF SCHERTZ DISCRETIONS.
6.EXISTING LIFT STATION INFORMATION BASED ON
THE RIATA UNIT 1 CONSTRUCTION PLANS DATED
APRIL, 2006 BY CORWIN ENGINEERING, INC., AND
EXISTING CONDITIONS SURVEY BY DYE
ENTERPRISES, DECEMBER 2020.
7.ABANDONED MANHOLES SHALL BE REMOVED TO A
LEVEL NOT LESS THAN FOUR FEET BELOW GRADE,
INLETS AND OUTLETS SECURELY PLUGGED, INLET
AND OUTLET PIPES CUT AND PLUGGED OUTSIDE THE
MANHOLE, AND THE STRUCTURE FILLED WITH
STABILIZED SAND. SEE DETAIL IN LS-14.
8.CONTRACTOR TO CUT, CAP, AND REMOVE THE
EXISTING 6" FORCE MAIN PER CITY OF SCHERTZ
STANDARDS. CONTRACTOR TO COORDINATE
ABANDONMENT WITH CITY AND ENGINEER.
UT
I
L
I
T
Y
EN
G
I
N
E
E
R
I
N
G
GR
O
U
P
PL
L
C
Te
x
a
s
E
n
g
i
n
e
e
r
i
n
g
F
i
r
m
F
-
1
8
7
1
2
19
1
N
.
U
n
i
o
n
A
v
e
N
E
W
B
R
A
U
N
F
E
L
S
,
T
E
X
A
S
7
8
1
3
0
P
H
:
(
8
3
0
)
2
1
4
-
0
5
2
1
UEG
EXISTING PUMPS TO BE
REMOVED AND DELIVERED TO
CITY OF SCHERTZ
PROPOSED BOLLARD
PROPOSED CHAINLINK FENCE
LEGEND
PROPOSED WASTEWATER LINE
EXISTING MANHOLE
PROPOSED LIGHTPOLE
EXISTING TO BE REHABBED
PROPOSED WATER SERVICE
SITE INFORMATION:
LIFT STATION NUMBER/NAME: IH-35 RIATA LIFT STATION
RELOCATION AND OFFSITE SEWER IMPROVEMENTS
LOCATED AT: IH-35 , SCHERTZ, TEXAS
LATITUDE: N29° 37' 22.24" LONGITUDE: W98° 14' 37.41"
LOCATED WITHIN 100-YR FLOODPLAIN?: NO
LOCATED WITHIN EDWARDS AQUIFER?: NO
EXISTING 8-INCH SEWER MAIN
TO BE CUT, AND CAPPED
(SEE SHEET DM-1)
EXISTING VALVES AND
APPURTENANCES TO BE
SALVED PER CITY OF
SCHERTZ DISCRETION
EXISTING VALVES AND
APPURTENANCES TO BE SALVED
PER CITY OF SCHERTZ DISCRETION
CAP EXISTING
DRAINLINE
EXISTING 14-FT FIBERGLASS WET
WELL TO BE FILLED WITH CEMENT
STABILIZED SAND AND COVER
WITH TOP SOIL TO GRADE.
EXISTING CONCRETE SLAB &
ACCESS HATCHES TO BE
REMOVED.
PROP. BLIND FLANGE TO
BE WELDED TO PIPE
EXISTING PIPES TO BE
CUT AT WALL
EXISTING VALVE VAULT ROOF TO
BE REMOVED AND CUT DOWN
5-FEET BELOW GRADE. VAULT TO
BE FILLED WITH CEMENT
STABILIZED SAND AND COVERED
WITH TOP SOIL TO GRADE.
EXISTING PUMP CONTROLS
AND CONTROL PANELS TO BE
REMOVED AND DELIVERED TO
CITY OF SCHERTZ
(SEE ELECTRICAL PLANS FOR
EXISTING LIFT STATION
ELECTRICAL DEMO)
EXISTING CONCRETE SLAB
SHALL BE CUT DOWN 5-FEET
BELOW GRADE. WET WELL TO
BE FILLED WITH CEMENT
STABILIZED SAND AND
COVERED WITH COMPACTED
TOP SOIL TO GRADE AND
REVEGETATE
36
DM-2
DK
PND
PND
DE
M
O
S
H
E
E
T
2
O
F
2
IH
-
3
5
R
I
A
T
A
L
I
F
T
S
T
A
T
I
O
N
R
E
L
O
C
A
T
I
O
N
A
N
D
OF
F
S
I
T
E
S
E
W
E
R
I
M
P
R
O
V
E
M
E
N
T
S
8032-03
30 January, 2023
EXISTING 5-FT DIA. MH TO
BE ABANDONED
(SEE NOTE 7 AND DETAIL
SHEET LS-14)
EXISTING 5-FT DIA. MH TO
BE ABANDONED
(SEE NOTE 7 AND DETAIL
SHEET LS-14)
NOTES:
1.EXISTING LIFT STATION TO CONTINUE OPERATION
UNTIL RELOCATION OF PROPOSED STATION HAS
BEEN COMPLETED, TESTED, AND ACCEPTED FOR
SERVICE OPERATIONS BY ENGINEER AND CITY OF
SCHERTZ. CONTRACTOR TO COORDINATE EXISTING
LIFT STATION DECOMMISSIONING WITH CITY AND
ENGINEER.
2.CONTRACTOR TO COORDINATE PROPOSED OFF-SITE
8" GRAVITY MAIN AND PROPOSED OFF-SITE 6"
FORCE MAIN MAIN CONNECTIONS WITH CITY OF
SCHERTZ.
3.CONTRACTOR TO PROVIDE A BY-PASS PUMPING
PLAN FOR THE PROJECT FOR APPROVAL BY
ENGINEER AND THE CITY OF SCHERTZ PRIOR TO
CONSTRUCTION.
4.CONTRACTOR TO CUT, CAP AND ABANDON THE
EXISTING 8" GRAVITY MAIN PER CITY OF SCHERTZ
STANDARDS. CONTRACTOR TO COORDINATE
ABANDONMENT WITH CITY AND ENGINEER.
5.ALL EXISTING LIFT STATION PUMPS, VALVES,
APPURTENANCES, FENCING, CONTROL PANELS,
WIRING, ETC. TO BE REMOVED AND SALVAGED PER
CITY OF SCHERTZ DISCRETIONS.
6.EXISTING LIFT STATION INFORMATION BASED ON
THE RIATA UNIT 1 CONSTRUCTION PLANS DATED
APRIL, 2006 BY CORWIN ENGINEERING, INC., AND
EXISTING CONDITIONS SURVEY BY DYE
ENTERPRISES, DECEMBER 2020.
7.ABANDONED MANHOLES SHALL BE REMOVED TO A
LEVEL NOT LESS THAN FOUR FEET BELOW GRADE,
INLETS AND OUTLETS SECURELY PLUGGED, INLET
AND OUTLET PIPES CUT AND PLUGGED OUTSIDE THE
MANHOLE, AND THE STRUCTURE FILLED WITH
STABILIZED SAND. SEE DETAIL IN LS-14.
8.CONTRACTOR TO CUT, CAP, AND REMOVE THE
EXISTING 6" FORCE MAIN PER CITY OF SCHERTZ
STANDARDS. CONTRACTOR TO COORDINATE
ABANDONMENT WITH CITY AND ENGINEER.
6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL
PROPOSED 45'
UTILITY/ACCESS/
SITE EASEMENT
0+00
1+00
PROP. ASPHALT
PAVEMENT
ALL UNPAVED AREAS OF SITE
WITHIN FENCED BOUNDARIES
SHALL BE COVERED WITH WEED
BARRIER AND A 6" LAYER OF
TXDOT GRADE 1 COARSE
AGGREGATE. (SEE NOTE 5)
PROPOSED ELECTRICAL
SHELTER.
(SEE ELECTRICAL SHEETS)
PROPOSED
BACK OF CURB
(TXDOT IMPROVEMENTS)
PROPOSED
LIFT STATION ACCESS
ASPHALT DRIVEWAY
CONNECT TO EX.
PAVEMENT, SAW CUT
NEAT EDGE FOR
CONNECTION
EXISTING 15' GVSUD
UTILITY EASEMENT
PROP. TXDOT
RIGHT OF WAY
3+00 4+00
5+
0
0
5+
0
8
PROPOSED 12' DIA
WET WELL WITH
SUBMERSIBLE PUMPS
(SEE SHEET LS-5)
PROPOSED 5-FT DIA.
MH A-2 WITH
SMARTCOVER SYSTEM
(SEE SHEET LS-4)
PROPOSED BY-PASS
CONCRETE PAD.
(SEE SHEET LS-6)
EXISTING CITY OF
SCHERTZ 12-INCH
WATER MAIN
PROPOSED EMERGENCY
GENERATOR LOCATION.
(SEE ELECTRICAL SHEETS)
PROPOSED LIGHT POLE.
(SEE ELECTRICAL
SHEETS)
HOSE BIB
(SEE SHEET LS-9)
RPZ BACKFLOW
PREVENTER (SEE
SHEET LS-10 AND
NOTE 7)
PROP. 2" 125 L.F
WATER SERVICE.
TIE-IN TO EXISTING
12-INCH WATER LINE
(MIN. 5 8" METER SIZE)
(COORDINATE METER
& SERVICE WITH CITY
OF SCHERTZ)
6-INCH
GVSUD
WATER LINE
(CONTRACTOR
TO VERIFY
LOCATION)
EXISTING RIATA LIFT
STATION SITE TO BE
ABANDONED.
(SEE SHEET DM-1 & 2)
EXISTING
PROPERTY
LINE
PROPOSED 8'
CONCRETE
MASONRY FENCE.
(SEE NOTE 9)
PROPOSED 9"
CONCRETE FLUSH
CURB.
(SEE SHEET LS-11)
PROPOSED SCADA
TOWER FOR ANTENNA.
(SEE ELECTRICAL
SHEETS)
PROPOSED
LIFT STATION ACCESS
ASPHALT DRIVEWAY
PROPOSED
24-FT
SWING GATE
EXISTING
RIGHT OF WAY
PROPOSED
FUTURE WATER
LINE (BY OTHERS)
IH-35 FRONTAGE ROAD
PROPOSED
ACCESS/UTILITY
EASEMENT BOUNDARY
PROPOSED OFF-SITE 6-INCH
FORCE MAIN. TIE-IN TO
EXISTING 6-INCH LOCATED
IN FAIRLAWN AVENUE.
(SEE SHEET LS-5)
PROPOSED OFF-SITE 8-INCH
GRAVITY MAIN. TIE-IN TO
EXISTING 8-INCH LOCATED IN
FAIRLAWN AVENUE.
(SEE SHEET LS-4)
PROPOSED
TXDOT DRIVE
LOCATION
REMOVABLE
BOLLARD
6-INCH (TYP.)
PROPOSED 12' DIA
WET WELL WITH
SUBMERSIBLE PUMPS
(SEE SHEET LS-6)
PROPOSED LIGHT POLE.
(SEE ELECTRICAL
SHEETS)
TEMPORARY 20'
CONSTRUCTION
EASEMENT
PROPOSED
24-FT FLOOD
SWING GATE
WATER METER
(COORDINATE
WITH CITY OF
SCHERTZ)
PROPOSED 2- 8"X22"
PARKING SPACES
6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL
3+00
3+
6
6
PROPOSED 45'
UTILITY/ACCESS/SITE
EASEMENT
EXISTING
12-INCH
WATER LINE
EXISTING
4-INCH GAS LINE
1+00 2+00
PROPOSED OFF-SITE
6-INCH FORCE MAIN.
TIE-IN TO EXISTING
6-INCH LOCATED IN
FAIRLAWN AVENUE.
(SEE SHEET LS-5)
EXISTING
ROW
EXISTING
POWERPOLE
EXISTING 4-FT DIA.
WASTEWATER
MANHOLE TO BE
ABANDONED.
(SEE SHEET DM-2)
IH-35 FRONTAGE ROAD
PROPOSED 5-FT DIA.
DOGHOUSE MH A-1
STA. = 1+00.00
FUTURE
WATER LINE
(BY OTHERS)
PROP. TXDOT
ROW
FA
I
R
L
A
W
N
A
V
E
.
6-INCH GVSUD
WATER LINE
(CONTRACTOR
TO VERIFY
LOCATION)PROPOSED OFF-SITE 8-INCH
GRAVITY MAIN. TIE-IN TO
EXISTING 8-INCH LOCATED IN
FAIRLAWN AVENUE.
(SEE SHEET LS-4)
IH-35 FRONTAGE ROAD
FA
I
R
L
A
W
N
AV
E
.
TEMPORARY 20'
CONSTRUCTION
EASEMENT
F
A
I
R
L
A
W
N
A
V
E
N
U
E
H
U
B
E
R
T
U
S
R
D
.
PROJECT SITE:
IH-35 SCHERTZ, TX
IH-3
5
FM
4
8
2
15'BUFFERZONE
SITE INFORMATION:
LIFT STATION NUMBER/NAME: IH-35 RIATA LIFT STATION
RELOCATION AND OFFSITE SEWER IMPROVEMENTS
LOCATED AT: IH-35 , SCHERTZ, TEXAS
LATITUDE: N29° 37' 22.24" LONGITUDE: W98° 14' 37.41"
LOCATED WITHIN 100-YR FLOODPLAIN?: NO
LOCATED WITHIN EDWARDS AQUIFER?: NO
NOTES:
1.CONTRACTOR SHALL BE RESPONSIBLE FOR
PROTECTING EXISTING FEATURES DURING
CONSTRUCTION, ANY FEATURES DAMAGED SHALL
BE REPAIRED OR REPLACED AT CONTRACTOR'S
EXPENSE.
2.UTILITIES SUCH AS WATER, ELECTRIC, GAS, FIBER
OPTICS, AND TELECOMMUNICATIONS MAY EXIST
WITHIN THE WORK AREA. THE CONTRACTOR IS
RESPONSIBLE FOR VERIFYING THE LOCATION OF
ALL UTILITIES SHOWN AND NOT SHOWN. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE
TO THE UTILITIES CAUSED BY THE CONTRACTOR'S
OPERATION.
3.QUANTITIES SHOWN ARE ESTIMATES ONLY.
CONTRACTOR TO VERIFY ALL QUANTITIES.
4.INSTALL PROTECTIVE REMOVABLE BOLLARDS.
VERIFY LOCATION WITH CITY OF SCHERTZ
INSPECTOR.
5.ALL UNPAVED AREAS OF SITE WITHIN FENCED
BOUNDARIES SHALL BE COVERED WITH WEED
BARRIER AND A 6” LAYER OF TXDOT GRADE 1
COARSE AGGREGATE.
6.1” WOODFORD Y1 NON-FREEZE YARD HYDRANT WITH
50FT HEAVY DUTY RUBBER HOSE, BRASS
ADJUSTABLE SPRAY NOZZLE, AND MCMASTER-CARR
53325K33 HOSE RACK.
7.PROVIDE WATTS 009 RPZ BACKFLOW PREVENTER
WITH BRASS PIPE/FITTINGS/VALVES, INSULATED AND
HEATED ALUMINUM ENCLOSURE, AND
CAST-IN-PLACE REINFORCED CONCRETE PAD.
8.INSTALL PIPE UNIONS INSIDE ENCLOSURE ON EACH
SIDE OF RPZ ASSEMBLY. MINIMUM CLEARANCE
INSIDE THE ENCLOSURE SHALL BE 12" BELOW, 3"
ABOVE, AND 6" SIDES. PROVIDE LICENSED FIELD
TESTING CERTIFICATION FOR RPZ.
9.CONTRACTOR SHALL INSTALL AN 8-FOOT TALL
STANDARD LIMESTONE COLOR VERTI-CRETE (MODEL
VC-4.2-8) MASONRY CONCRETE FENCE AND GATE OR
APPROVED EQUAL. SEE SHEET LS-9, SEE DETAIL 18.
10.ALL ELECTRICAL FOR LIFT STATION TO BE SERVED
USING UNDERGROUND ONLY. SEE ELECTRICAL
SHEETS FOR DETAILS.
PROPOSED BOLLARD
LEGEND
PROPOSED WASTEWATER LINE
EXISTING MANHOLE
PROPOSED LIGHTPOLE
COARSE AGGREGATE
ASPHALT PAVEMENT
PROPOSED WATER SERVICE
PROPOSED MASONRY
CONCRETE FENCE
UT
I
L
I
T
Y
EN
G
I
N
E
E
R
I
N
G
GR
O
U
P
PL
L
C
Te
x
a
s
E
n
g
i
n
e
e
r
i
n
g
F
i
r
m
F
-
1
8
7
1
2
19
1
N
.
U
n
i
o
n
A
v
e
N
E
W
B
R
A
U
N
F
E
L
S
,
T
E
X
A
S
7
8
1
3
0
P
H
:
(
8
3
0
)
2
1
4
-
0
5
2
1
UEG
LOCATION MAP
36
LS-1
DK
PND
PND
LI
F
T
S
T
A
T
I
O
N
S
I
T
E
P
L
A
N
IH
-
3
5
R
I
A
T
A
L
I
F
T
S
T
A
T
I
O
N
R
E
L
O
C
A
T
I
O
N
A
N
D
OF
F
S
I
T
E
S
E
W
E
R
I
M
P
R
O
V
E
M
E
N
T
S
8032-03
01 February, 2023
6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL
PROPOSED 45'
UTILITY/ACCESS/
SITE EASEMENT
0+00
1+002+00
3+00 4+00
5+
0
0
5+
0
8
PROPOSED EMERGENCY
GENERATOR LOCATION
(SEE ELECTRICAL
SHEETS)
PROPOSED SCADA
TOWER FOR ANTENNA
(SEE ELECTRICAL
SHEETS)
PROPOSED
ACCESS/UTILITY
EASEMENT BOUNDARY
PROPOSED OFF-SITE 6-INCH
FORCE MAIN. TIE-IN TO
EXISTING 6-INCH LOCATED
IN FAIRLAWN AVENUE.
(SEE SHEET LS-5)
PROPOSED OFF-SITE 8-INCH
GRAVITY MAIN. TIE-IN TO
EXISTING 8-INCH LOCATED IN
FAIRLAWN AVENUE.
(SEE SHEET LS-4)
6-INCH
GVSUD
WATER LINE
(CONTRACTOR
TO VERIFY
LOCATION)
EXISTING 15' GVSUD
UTILITY EASEMENT
EXISTING
RIGHT OF WAY
PROP. TXDOT
RIGHT OF WAY
EXISTING RIATA LIFT
STATION SITE TO BE
ABANDONED.
(SEE SHEET DM-1 & 2)
PROPOSED
FUTURE WATER
LINE (BY OTHERS)
EXISTING
PROPERTY
LINE
EXISTING CITY OF
SCHERTZ 12-INCH
WATER MAIN
IH-35 FRONTAGE ROAD
STABILIZED
CONSTRUCTION
ENTRANCE
PROPOSED
TXDOT DRIVE
LOCATION
F.F.=786.26
PROPOSED SLAB
F.F.=785.62
PROPOSED SLAB
F.F.=785.62
PROPOSED SLAB
F.F.=785.62
PROPOSED SLAB
F.F.=785.62
F.F.=786.26
F.F.=786.26
F.F.=785.85
F.F.=785.47
F.F.=783.52
F.F.=783.52F.F.=783.52
F.F.=783.52
F.F.=785.47
PROPOSED ELECTRICAL
SHELTER
(SEE ELECTRICAL SHEETS)
10'
10'
TEMPORARY 20'
CONSTRUCTION
EASEMENT
7.5'
14'
3.5'
35 LF TREE
PROTECTION
109 LF TREE
PROTECTION 385 LF SILT FENCE
PROPOSED 12' DIA
WET WELL WITH
SUBMERSIBLE PUMPS
(SEE SHEET LS-6)
87 LF SILT FENCE
188 LF
SILT FENCE
F.F.=786.26
6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL
FA
I
R
L
A
W
N
AV
E
.
PROPOSED OFF-SITE 8-INCH
GRAVITY MAIN. TIE-IN TO
EXISTING 8-INCH LOCATED IN
FAIRLAWN AVENUE.
(SEE SHEET LS-4)
EXISTING
12-INCH
WATER LINE
EXISTING
4-INCH GAS LINE
EXISTING
ROW
EXISTING
POWERPOLE
IH-35 FRONTAGE ROAD
FUTURE
WATER LINE
(BY OTHERS)
PROP. TXDOT
ROW
6-INCH GVSUD
WATER LINE
(CONTRACTOR
TO VERIFY
LOCATION)
PROPOSED OFF-SITE
6-INCH FORCE MAIN.
TIE-IN TO EXISTING
6-INCH LOCATED IN
FAIRLAWN AVENUE.
(SEE SHEET LS-5)TEMPORARY 20' CONSTRUCTION EASEMENT
63 LF TREE
PROTECTION
38 LF TREE
PROTECTION
188 LF
SILT FENCE
SITE INFORMATION:
LIFT STATION NUMBER/NAME: IH-35 RIATA LIFT STATION
RELOCATION AND OFFSITE SEWER IMPROVEMENTS
LOCATED AT: IH-35 , SCHERTZ, TEXAS
LATITUDE: N29° 37' 22.24" LONGITUDE: W98° 14' 37.41"
LOCATED WITHIN 100-YR FLOODPLAIN?: NO
LOCATED WITHIN EDWARDS AQUIFER?: NO
PROPOSED BOLLARD
LEGEND
PROPOSED WASTEWATER LINE
EXISTING MANHOLE
PROPOSED LIGHTPOLE
COARSE AGGREGATE
ASPHALT PAVEMENT
PROPOSED WATER SERVICE
PROPOSED MASONRY
CONCRETE FENCE
UT
I
L
I
T
Y
EN
G
I
N
E
E
R
I
N
G
GR
O
U
P
PL
L
C
Te
x
a
s
E
n
g
i
n
e
e
r
i
n
g
F
i
r
m
F
-
1
8
7
1
2
19
1
N
.
U
n
i
o
n
A
v
e
N
E
W
B
R
A
U
N
F
E
L
S
,
T
E
X
A
S
7
8
1
3
0
P
H
:
(
8
3
0
)
2
1
4
-
0
5
2
1
UEG
36
LS-2
DK
PND
PND
LI
F
T
S
T
A
T
I
O
N
G
R
A
D
I
N
G
,
E
R
O
S
I
O
N
&
S
E
D
I
M
E
N
T
A
T
I
O
N
C
O
N
T
R
O
L
PL
A
N
IH
-
3
5
R
I
A
T
A
L
I
F
T
S
T
A
T
I
O
N
R
E
L
O
C
A
T
I
O
N
A
N
D
OF
F
S
I
T
E
S
E
W
E
R
I
M
P
R
O
V
E
M
E
N
T
S
8032-03
01 February, 2023
NOTES:
1.CONTRACTOR SHALL BE RESPONSIBLE FOR
PROTECTING EXISTING FEATURES DURING
CONSTRUCTION, ANY FEATURES DAMAGED SHALL
BE REPAIRED OR REPLACED AT CONTRACTOR'S
EXPENSE.
2.UTILITIES SUCH AS WATER, ELECTRIC, GAS, FIBER
OPTICS, AND TELECOMMUNICATIONS MAY EXIST
WITHIN THE WORK AREA. THE CONTRACTOR IS
RESPONSIBLE FOR VERIFYING THE LOCATION OF
ALL UTILITIES SHOWN AND NOT SHOWN. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE
TO THE UTILITIES CAUSED BY THE CONTRACTOR'S
OPERATION.
3.QUANTITIES SHOWN ARE ESTIMATES ONLY.
CONTRACTOR TO VERIFY ALL QUANTITIES.
4.INSTALL PROTECTIVE REMOVABLE BOLLARDS.
VERIFY LOCATION WITH CITY OF SCHERTZ
INSPECTOR.
5.ALL UNPAVED AREAS OF SITE WITHIN FENCED
BOUNDARIES SHALL BE COVERED WITH WEED
BARRIER AND A 6” LAYER OF TXDOT GRADE 1
COARSE AGGREGATE.
6.1” WOODFORD Y1 NON-FREEZE YARD HYDRANT WITH
50FT HEAVY DUTY RUBBER HOSE, BRASS
ADJUSTABLE SPRAY NOZZLE, AND MCMASTER-CARR
53325K33 HOSE RACK.
7.PROVIDE WATTS 009 RPZ BACKFLOW PREVENTER
WITH BRASS PIPE/FITTINGS/VALVES, INSULATED AND
HEATED ALUMINUM ENCLOSURE, AND
CAST-IN-PLACE REINFORCED CONCRETE PAD.
8.INSTALL PIPE UNIONS INSIDE ENCLOSURE ON EACH
SIDE OF RPZ ASSEMBLY. MINIMUM CLEARANCE
INSIDE THE ENCLOSURE SHALL BE 12" BELOW, 3"
ABOVE, AND 6" SIDES. PROVIDE LICENSED FIELD
TESTING CERTIFICATION FOR RPZ.
9.CONTRACTOR SHALL INSTALL AN 8-FOOT TALL
STANDARD LIMESTONE COLOR VERTI-CRETE (MODEL
VC-4.2-8) MASONRY CONCRETE FENCE AND GATE OR
APPROVED EQUAL. SEE SHEET LS-9, SEE DETAIL 18.
10.ALL ELECTRICAL FOR LIFT STATION TO BE SERVED
USING UNDERGROUND ONLY. SEE ELECTRICAL
SHEETS FOR DETAILS.
6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL
10'
BUFFER ZONE
24'10'
BUFFER ZONE
20'
BUFFER ZONE
24'
10'
65'
5'
195'
10'
BUFFER ZONE
R
2
5
'
12'
137'
R25'
R48
'
34'76'60'
60'R25'
10'
BUFFER ZONE
66'
30'
BUFFER ZONE
10'
BUFFER ZONE
27'
PROPOSED 45'
UTILITY/ACCESS/SITE
EASEMENT
7.5'
15'
N = 13774768.52
E = 2208628.09
N = 13774734.28
E = 2208619.27
N = 13774718.67
E = 2208628.49
N = 13774710.20
E = 2208661.77
N = 13774797.35
E = 2208807.68
N = 13774776.67
E = 2208819.94
N = 13774764.79
E = 2208800.05
N = 13774730.62
E = 2208791.34
N = 13774710.58
E = 2208803.18
N = 13774698.38
E = 2208782.51
N = 13774718.09
E = 2208770.87
N = 13774726.84
E = 2208736.52
N = 13774689.59
E = 2208674.08
N = 13774706.47
E = 2208607.83
N = 13774722.08
E = 2208598.61
N = 13774730.89
E = 2208564.37
N = 13774637.75
E = 2208723.86 N = 13774737.33
E = 2208892.06
N = 13774838.22
E = 2208832.29
N = 13774855.42
E = 2208822.09
N = 13774746.65
E = 2208677.16
N = 13774718.20
E = 2208589.71
N = 13774611.92
E = 2208446.59
N = 13774579.51
E = 2208465.79
N = 13774684.28
E = 2208620.78
N = 13774661.12
E = 2208634.46
N = 13774694.68
E = 2208690.33
N = 13774657.01
E = 2208732.75
N = 13774746.09
E = 2208680.18
N = 13774742.50
E = 2208693.83
N = 13774670.98
E = 2208736.05
N = 13774735.07
E = 2208844.58
N = 13774806.53
E = 2208802.24
N = 13774731.77
E = 2208858.16
N = 13774637.58
E = 2208453.20
N = 13774820.22
E = 2208805.76
N = 13774707.49
E = 2208727.82
N = 13774698.48
E = 2208733.13
N = 13774724.91
E = 2208752.93
N = 13774704.37
E = 2208747.62
N = 13774576.08
E = 2208422.01
N = 13774577.61
E = 2208411.69
N = 13774719.08
E = 2208645.05
15'
BUFFER
ZONE
N = 13774755.34
E = 2208726.30
TEMPORARY 20'
CONSTRUCTION
EASEMENT
IH-35 FRONTAGE ROAD
L1
L2
L3
C
1
L4
C2
L5
L6
L7
C3
L8
L9
L10
C4
L1
1
L1
2
BM#2
MAG NAIL IN ASPHALT
N = 13774647.23
E = 2208412.73
ELEV: 800.88
10'
14'
3.5'
5'
MIN.
15'
FOR ELECTRICAL
COMPONENT LOCATION
SEE ELECTRICAL PLANS
FOR ELECTRICAL
COMPONENT LOCATION
SEE ELECTRICAL PLANS
Line Table
Line #
L1
L2
L3
L4
L5
L6
L7
L8
L9
L10
L11
L12
Length
23.971
24.107
19.307
72.708
22.886
24.000
23.270
23.164
24.000
169.961
19.307
24.220
Direction
S59° 10' 04.94"W
S30° 44' 53.03"E
S30° 34' 26.91"E
N59° 11' 10.17"E
S30° 33' 29.23"E
N59° 26' 30.77"E
N30° 33' 29.23"W
N59° 08' 40.46"E
N30° 38' 49.02"W
S59° 09' 44.70"W
N30° 34' 41.29"W
N30° 48' 48.80"W
Curve Table
Curve #
C1
C2
C3
C4
Length
75.990
39.400
39.140
38.168
Radius
48.220
25.000
25.000
24.220
Delta
090.2926
090.2973
089.7027
090.2926
SITE INFORMATION:
LIFT STATION NUMBER/NAME: IH-35 RIATA LIFT STATION
RELOCATION AND OFFSITE SEWER IMPROVEMENTS
LOCATED AT: IH-35 , SCHERTZ, TEXAS
LATITUDE: N29° 37' 22.24" LONGITUDE: W98° 14' 37.41"
LOCATED WITHIN 100-YR FLOODPLAIN?: NO
LOCATED WITHIN EDWARDS AQUIFER?: NO
NOTES:
1.CONTRACTOR SHALL BE RESPONSIBLE FOR
PROTECTING EXISTING FEATURES DURING
CONSTRUCTION, ANY FEATURES DAMAGED SHALL
BE REPAIRED OR REPLACED AT CONTRACTOR'S
EXPENSE.
2.UTILITIES SUCH AS WATER, ELECTRIC, GAS, FIBER
OPTICS, AND TELECOMMUNICATIONS MAY EXIST
WITHIN THE WORK AREA. THE CONTRACTOR IS
RESPONSIBLE FOR VERIFYING THE LOCATION OF
ALL UTILITIES SHOWN AND NOT SHOWN. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE
TO THE UTILITIES CAUSED BY THE CONTRACTOR'S
OPERATION.
3.QUANTITIES SHOWN ARE ESTIMATES ONLY.
CONTRACTOR TO VERIFY ALL QUANTITIES.
PROPOSED BOLLARD
LEGEND
PROPOSED WASTEWATER LINE
EXISTING MANHOLE
PROPOSED LIGHTPOLE
COARSE AGGREGATE
ASPHALT PAVEMENT
PROPOSED WATER SERVICE
PROPOSED MASONRY
CONCRETE FENCE
UT
I
L
I
T
Y
EN
G
I
N
E
E
R
I
N
G
GR
O
U
P
PL
L
C
Te
x
a
s
E
n
g
i
n
e
e
r
i
n
g
F
i
r
m
F
-
1
8
7
1
2
19
1
N
.
U
n
i
o
n
A
v
e
N
E
W
B
R
A
U
N
F
E
L
S
,
T
E
X
A
S
7
8
1
3
0
P
H
:
(
8
3
0
)
2
1
4
-
0
5
2
1
UEG
36
LS-3
DK
PND
PND
DI
M
E
N
S
I
O
N
C
O
N
T
R
O
L
S
H
E
E
T
IH
-
3
5
R
I
A
T
A
L
I
F
T
S
T
A
T
I
O
N
R
E
L
O
C
A
T
I
O
N
A
N
D
OF
F
S
I
T
E
S
E
W
E
R
I
M
P
R
O
V
E
M
E
N
T
S
8032-03
01 February, 2023
FA
I
R
L
A
W
N
A
V
E
OFF-SITE 8" GRAVITY MAIN PROFILE VIEW
760
765
770
775
780
785
790
795
800
760
765
770
775
780
785
790
795
800
PR
O
P
.
W
E
T
W
E
L
L
ST
A
.
=
5
+
0
0
.
4
0
(N
W
)
F
L
I
N
(
8
"
)
=
7
7
6
.
0
2
TO
P
=
7
8
5
.
6
2
PR
O
P
.
5
'
D
I
A
SS
M
A
N
H
O
L
E
M
H
A
-
2
W
I
T
H
S
M
A
R
T
C
O
V
E
R
S
Y
S
T
E
M
ST
A
.
=
4
+
5
3
.
1
6
(S
W
)
F
L
I
N
(
8
"
)
=
7
7
6
.
3
1
(S
E
)
F
L
O
U
T
(
8
"
)
=
7
7
6
.
2
1
TO
P
=
7
8
6
.
0
0
PR
O
P
.
5
'
D
I
A
SS
D
O
G
H
O
U
S
E
M
A
N
H
O
L
E
A
-
1
ST
A
.
=
1
+
0
0
.
0
0
(S
E
)
F
L
I
N
(
8
"
)
=
7
7
7
.
8
5
(
E
X
.
)
(N
W
)
F
L
O
U
T
(
8
"
)
=
7
7
7
.
8
5
(N
E
)
F
L
O
U
T
(
8
"
)
=
7
7
7
.
7
3
TO
P
=
8
0
1
.
9
9
353' of 8" SDR 26 PVC @ 0.40%
47' of 8"
SDR 26 PVC
@ 0.40%
EXISTING GROUND
(E
X
.
)
(
A
B
A
N
D
O
N
S
E
E
S
H
E
E
T
S
(P
R
O
P
.
)
PROPOSED GROUND
DM
-
1
&
D
M
-
2
)
6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL 6 WL
PROPOSED 45'
UTILITY/ACCESS/
SITE EASEMENT
0+00
1+002+003+00
3+
6
6
1+00 2+00 3+00 4+00
5+
0
0
5+
0
8
EXISTING 4-FT DIA.
WASTEWATER MANHOLE
TO BE ABANDONED.
(SEE SHEET DM-2)
PROPOSED OFF-SITE 6-INCH
FORCE MAIN. TIE-IN TO
EXISTING 6-INCH LOCATED IN
FAIRLAWN AVENUE. (SEE
SHEET LS-5)
FUTURE WATER
LINE
(BY OTHERS)
PROP. TXDOT ROW
6-INCH GVSUD WATER
LINE (CONTRACTOR
TO VERIFY LOCATION)
PROPOSED OFF-SITE 6-INCH
FORCE MAIN. TIE-IN TO
EXISTING 6-INCH LOCATED
IN FAIRLAWN AVENUE.
(SEE SHEET LS-5)
PROPOSED OFF-SITE 8-INCH
GRAVITY MAIN. TIE-IN TO
EXISTING 8-INCH LOCATED IN
FAIRLAWN AVENUE.
6-INCH
GVSUD
WATER LINE
(CONTRACTOR
TO VERIFY
LOCATION)
PROPOSED 5-FT DIA.
WASTEWATER MH A-2
WITH SMARTCOVER
SYSTEM
(PROPOSED 12' DIA
WET WELL WITH
SUBMERSIBLE PUMPS
(SEE SHEET LS-6)
10'
10'
TEMPORARY 20'
CONSTRUCTION
EASEMENT
7.5'
14'
3.5'
PROPOSED 5-FT DIA.
DOGHOUSE MH A-1
STA. = 1+00.00
22 SY OF
ASPHALT ROAD
REPAIR AND
CONCRETE CURB
84 SY OF
ASPHALT ROAD
REPAIR AND
CONCRETE CURB
SITE INFORMATION:
LIFT STATION NUMBER/NAME: IH-35 RIATA LIFT STATION
RELOCATION AND OFFSITE SEWER IMPROVEMENTS
LOCATED AT: IH-35 , SCHERTZ, TEXAS
LATITUDE: N29° 37' 22.24" LONGITUDE: W98° 14' 37.41"
LOCATED WITHIN 100-YR FLOODPLAIN?: NO
LOCATED WITHIN EDWARDS AQUIFER?: NO
NOTES:
1.OPEN CUT AND REPAIR ASPHALT & GRAVEL DRIVES
PER DETAILS, MATCH EXISTING MATERIAL
2.CONTRACTOR TO JOINT RESTRAIN ALL CONNECTION
INTO EXISTING LINES, VALVES & FITTINGS.
3.CONTRACTOR TO FIELD VERIFY DEPTH, LOCATION,
MATERIAL TYPE, AND SIZE OF EXISTING
WASTEWATER LINES.
4.CONTRACTOR RESPONSIBLE FOR ALL FENCING
REPAIR.
5.ALL CONSTRUCTION ACTIVITIES TO REMAIN WITHIN
THE PERMANENT AND TEMPORARY EASEMENTS AND
RIGHT-OF-WAY.
PROPOSED BOLLARD
LEGEND
PROPOSED WASTEWATER LINE
EXISTING MANHOLE
PROPOSED LIGHTPOLE
COARSE AGGREGATE
ASPHALT PAVEMENT
PROPOSED WATER SERVICE
PROPOSED MASONRY
CONCRETE FENCE
UT
I
L
I
T
Y
EN
G
I
N
E
E
R
I
N
G
GR
O
U
P
PL
L
C
Te
x
a
s
E
n
g
i
n
e
e
r
i
n
g
F
i
r
m
F
-
1
8
7
1
2
19
1
N
.
U
n
i
o
n
A
v
e
N
E
W
B
R
A
U
N
F
E
L
S
,
T
E
X
A
S
7
8
1
3
0
P
H
:
(
8
3
0
)
2
1
4
-
0
5
2
1
UEG
36
LS-4
DK
PND
PND
OF
F
-
S
I
T
E
8
'
'
G
R
A
V
I
T
Y
M
A
I
N
IH
-
3
5
R
I
A
T
A
L
I
F
T
S
T
A
T
I
O
N
R
E
L
O
C
A
T
I
O
N
A
N
D
OF
F
S
I
T
E
S
E
W
E
R
I
M
P
R
O
V
E
M
E
N
T
S
8032-03
01 February, 2023
FA
I
R
L
A
W
N
A
V
E
6 WL6 WL6 WL6 WL6 WL6 WL6 WL6 WL6 WL6 WL6 WL6 WL6 WL6 WL6 WL6 WL6 WL6 WL6 WL6 WL6 WL6 WL6 WL6 WL6 WL6 WL6 WL
0+00
1+00 2+00 3+00
3+
6
6
PROPOSED 12' DIA
WET WELL WITH
SUBMERSIBLE PUMPS
(SEE SHEET LS-6)
BEGINNING OF 6'' FORCE MAIN
STA: 0+08.23 INSTALL:
1 - 6'' MJ 45° BEND
STA: 0+89.86 INSTALL:
1 - 6'' MJ 45° BEND
N75° 59' 17.03"W 82'
1+002+003+004+00
5+
0
0
5+
0
8
PROPOSED 45-FT
UTILITY/ACCESS/SITE
EASEMENT
FA
I
R
L
A
W
N
A
V
E
.
IH-35 FRONTAGE ROAD
PROPOSED LIFT
STATION SITE.
(SEE SHEET LS-1)
20'
7.5'
10'
10'
14'
3.5'
STA: 0+75.60
WARNING! EXIST.
WASTEWATER MAIN CROSSING
N: 13774715.6268
E: 2208658.8850
84SY OF ASPHALT
ROAD REPAIR AND
CONCRETE CURB
22 SY OF ASPHALT
ROAD REPAIR AND
CONCRETE CURB
STA: 3+59.25 INSTALL:
1 - 6'' MJ 45° BEND
END OF FORCE MAIN STA: 3+64.14
TIE-IN PROP. 6" FM TO EXIST. 6" FM
INSTALL 1-6" WYE
(CONTRACTOR TO VERIFY
TIE-IN ELEVATION)
N: 13774577.6144
E: 2208411.6839
STA: 3+54.61
WARNING! EXIST.
WASTEWATER MAIN CROSSING
N: 13774584.6957
E: 2208416.9321
OFF-SITE 6'' FM PROFILE VIEW
773
775
780
785
790
773
775
780
785
790
TI
E
-
I
N
T
O
P
R
O
P
.
6
"
F
.
M
.
TO
P
R
O
P
.
Y
A
R
D
P
I
P
I
N
G
ST
A
:
0
+
0
8
.
2
3
I
N
S
T
A
L
L
:
1
-
6
'
'
M
J
4
5
°
B
E
N
D
FL
=
7
8
0
.
2
0
ST
A
:
0
+
8
9
.
8
6
I
N
S
T
A
L
L
:
1
-
6
'
'
M
J
4
5
°
B
E
N
D
FL
=
7
8
3
.
5
7
81' OF 6" C-900 DR-14 FORCE MAIN @ -4.15%
EXISTING GROUND
0+00
EG
=
7
8
5
.
3
4
FL
=
1+00
EG
=
7
8
9
.
9
0
FL
=
7
8
4
.
0
4
1+50
EG
=
7
9
1
.
6
8
FL
=
7
8
6
.
3
7
4' MIN.
PROPOSED GROUND
PR
O
P
O
S
E
D
8
"
W
A
S
T
E
W
A
T
E
R
ST
A
.
=
0
+
7
5
.
5
5
FL
=
7
7
6
.
6
3
7' OF 6" SDR 26 FORCE MAIN @ 0.00%
OFF-SITE 6'' FM PROFILE VIEW
775
780
785
790
795
800
775
780
785
790
795
800
1+50
EG
=
7
9
1
.
6
8
FL
=
7
8
6
.
3
7
2+00
EG
=
7
9
4
.
0
2
FL
=
7
8
8
.
6
9
3+00
EG
=
7
9
9
.
0
0
FL
=
7
9
3
.
3
3
4+00
EG
=
FL
=
4' MIN.
EXSTING GROUND
ST
A
:
3
+
5
9
.
2
5
I
N
S
T
A
L
L
:
1
-
6
'
'
M
J
4
5
°
B
E
N
D
FL
=
7
9
6
.
0
9
PR
O
P
O
S
E
D
8
"
W
A
S
T
E
W
A
T
E
R
ST
A
.
=
3
+
4
6
.
4
4
FL
=
7
7
7
.
9
0
269' O
F
6
"
C
-
9
0
0
D
R
-
1
4
F
O
R
C
E
M
A
I
N
@
-
4
.
6
5
%
3' OF 6" C-900 DR-14 FORCE MAIN @ -5.07%
ST
A
:
3
+
6
4
.
1
4
I
N
S
T
A
L
L
:
1
-
6
"
W
Y
E
FL
=
7
9
6
.
2
3
SITE INFORMATION:
LIFT STATION NUMBER/NAME: IH-35 RIATA
LIFT STATION RELOCATION AND OFFSITE
SEWER IMPROVEMENTS
LOCATED AT: IH-35 , SCHERTZ, TEXAS
LATITUDE: N29° 37' 22.24" LONGITUDE: W98°
14' 37.41"
LOCATED WITHIN 100-YR FLOODPLAIN?: NO
LOCATED WITHIN EDWARDS AQUIFER?: NO
PROPOSED BOLLARD
LEGEND
PROPOSED WASTEWATER LINE
EXISTING MANHOLE
PROPOSED LIGHTPOLE
COARSE AGGREGATE
ASPHALT PAVEMENT
PROPOSED WATER SERVICE
PROPOSED MASONRY
CONCRETE FENCE
UT
I
L
I
T
Y
EN
G
I
N
E
E
R
I
N
G
GR
O
U
P
PL
L
C
Te
x
a
s
E
n
g
i
n
e
e
r
i
n
g
F
i
r
m
F
-
1
8
7
1
2
19
1
N
.
U
n
i
o
n
A
v
e
N
E
W
B
R
A
U
N
F
E
L
S
,
T
E
X
A
S
7
8
1
3
0
P
H
:
(
8
3
0
)
2
1
4
-
0
5
2
1
UEG
36
LS-5
DK
PND
PND
OF
F
-
S
I
T
E
6
'
'
F
O
R
C
E
M
A
I
N
IH
-
3
5
R
I
A
T
A
L
I
F
T
S
T
A
T
I
O
N
R
E
L
O
C
A
T
I
O
N
A
N
D
OF
F
S
I
T
E
S
E
W
E
R
I
M
P
R
O
V
E
M
E
N
T
S
8032-03
01 February, 2023
NOTES:
1.OPEN CUT AND REPAIR ASPHALT &
GRAVEL DRIVES PER DETAILS, MATCH
EXISTING MATERIAL
2.CONTRACTOR TO JOINT RESTRAIN ALL
CONNECTION INTO EXISTING LINES,
VALVES & FITTINGS.
3.CONTRACTOR TO FIELD VERIFY DEPTH,
LOCATION, MATERIAL TYPE, AND SIZE
OF EXISTING WASTEWATER LINES.
4.CONTRACTOR RESPONSIBLE FOR ALL
FENCING REPAIR.
5.ALL CONSTRUCTION ACTIVITIES TO
REMAIN WITHIN THE PERMANENT AND
TEMPORARY EASEMENTS AND
RIGHT-OF-WAY.
6.CONTRACTOR TO INSTALL
DEFLECTIONS AT BENDS PER
MANUFACTURES RECOMMENDATIONS
TO MAINTAIN PROFILE GRADE.
7.FORCE MAIN SHALL BE C-900, DR-14 PVC
PIPE (GREEN) SEWER PIPE.
8.PLUG VALVES SHOULD HAVE A VALVE
BOX PER CIT OF SCHERTZ STANDARD
WATER VALVE BOX DETAIL EXCEPT
LIDS.
MA
T
C
H
L
I
N
E
SE
E
T
H
I
S
S
H
E
E
T
SE
E
T
H
I
S
S
H
E
E
T
MA
T
C
H
L
I
N
E
CO
N
N
E
C
T
T
O
E
X
.
6
"
F
O
R
C
E
M
A
I
N
IH-35 RIATA LIFT STATION DESIGN PUMPS:
SUPPLY 2 ITT FLYGT HIGH EFFICIENCY
SUBMERSIBLE PUMP MODEL NP3153 SH
3~274, 23 HP, 3505 RPM 6 29
32" IMPELLER, NO
EQUIVALENT. INSTALL 2 PUMPS WITH
2 MIX FLUSH VALVES THIS CONTRACT,
AND INSTALL PIPING, RAILS, ETC FOR 2
PUMPS.
6" 90° BEND
6" FLEX COUPLING W/ RESTRAINTS
6" X 4" REDUCER
6" CHECK VALVE (HYDRAULIC DAMPENING)
(VERIFY FLOW DIRECTION WITH
INSPECTOR PRIOR TO INSTALLATION)
6" PLUG VALVE
6" 45° BEND
6" CLASS 54 DUCTILE, LENGTH AS
REQUIRED
6" X 6" WYE
6" TEE
6" PLUG VALVE W/ BOX
6" EMERGENCY BYPASS W/ 316SS QUICK
COUPLER AND PLUG
8" PVC
STILLING WELL
(SEE ROOF PLAN
THIS SHEET)
2'
(MIN.)
2'
(MIN.)
2'
(MIN.)2'
(MIN.)
4'
6'
2'
(MIN.)
11'-5"
10'-5"
9'-5"
8'-5"
8'
MIN.
PROPOSED 8"
SDR 26 PVC
(SEE SHEET
LS-4)
PUMP ACCESS HATCH WITH MIN. OF
48" X 72" CLEAR OPENING OR AS
REQ'D BY PUMP MANUFACTURER
(SEE NOTE 2) WITH ALUMINUM
SAFETY GRATES AND COVERS WITH
PADLOCKS STAPLES AND COVER
ELECTRICAL NOTE:
SEE ELECTRICAL PLANS FOR JUNCTION BOX
LOCATION AND DETAILS. CONTRACTOR TO
COORDINATE FINAL JUNCTION BOX LOCATIONS WITH
ENGINEER AND OWNER PRIOR TO INSTALLATION.
INSTALL SEAL OFF FITTINGS WITH 3M-2123 FOR ALL
CONDUITS, ROUTE WET WELL IN SLAB (NOT EXPOSED),
STUBUP FROM SLAB WITH PVC COATED GRS FACTORY
90-BENDS, BELL END ADAPTERS AT HATCH.
PROPOSED
PRESSURE
GAUGE
2" COMBINATION
AIR/VACUUM
RELEASE VALVE
(A.R.I. MODEL D-025)
SEE SHEET LS-5
FOR FORCE MAIN
CONTINUATION.
4" FLOOR
DRAIN PIPE
CONCRETE PAD (SEE
BYPASS RISER AND
VALVE. THIS SHEET)
CONCRETE VALVE VAULT
MIN 48" X 72" ACCESS TO
OPEN IN DIRECTION OF
THE WET WELL.
BEGINNING OF
FORCE MAIN
ALIGNMENT
LIFT
STATION
ALIGNMENT
PLAN VIEW @ GRADE
2'
(MIN.)
2'
(MIN.)
6" MIN .
WET WELL VENT WITH
316 SS SCREEN FLANGED
(SEE SHEET LS-10)
SEE STRUCTURAL
PLAN SHEETS FOR
WET WELL SLAB
4 " MIN. DIA.
VALVE VAULT VENT
WITH 316 SS
SCREEN FLANGED
(SEE SHEET LS-10)
PROPOSED LADDER
(SEE DETAIL SHEET LS-8)5'-5"
MIN.
HOFFMAN NEMA 4X
SS JUNCTION BOX W/
GASKETED FRONT
COVER..
(SEE ELECTRICAL
SHEETS)
WET WELL PIPING SUPPORT DETAIL
NOTE: ALL MATERIAL SHALL BE 316SS,
ALL NUTS SHALL BE LOCK NUTS,
INSTALL FLAT WASHERS FOR ALL
BOLTS AND NUTS
1/2" THREADED
316SS RODS
BRACKET DETAIL FOR
PIPE AND PUMP GUIDE
RAIL SUPPORT, ALL
COMPONENTS SHALL BE
316SS
LATERAL SUPPORT C4x7.25 316SS CHANNEL
WELDED TO 6" X 6" X 1/2" 316SS PLATES.
BEND PLATES TO MATCH WET WELL
CURVATURE. MOUNT TO WET WELL WALL
USING 4 EACH 1/2" DIAMETER 316SS EPOXY
ANCHOR BOLTS MINIMUM. SET 1/2"
NEOPRENE GASKET ON WET WELL WALL
SURFACES IN SIKA 1A (OR EQUAL) SEALANT.
P-1 P-2
INSTALL ALL PIPING
RAILS, ETC. FOR ALL TWO
PUMPS
BYPASS RISER & VALVE
6" PLUG
VALVE MJ
STANDARD C.I.
VALVE & BOX
ASSEMBLY SEE TYPICAL
EXTERIOR
EQUIPMENT
PAD DETAIL
CAST IRON COVER
LABELED
"WASTEWATER"
6" X 6"
TEE MJ
6" D.I.
PIPE
6" 90° BEND MJ
6" 90° BEND,
BLIND FLANGE
(FLG. X FLG.) &
CAMLOCK WITH
QUICK CONNECT
6" D.I.
PIPE
PROPOSED
GRADE
1 COAT OF STEEL PRIMER;
2 COATS OF EXTERIOR
ENAMEL
2'-6"
6"
CHECK
VALVE
(HYDRAULIC
DAMPENING)
INSTALL 316
S.S. PIPE
SUPPORT
WET WELL SECTION VIEW
P-1
P-2
C
R
I
S
E
R
P
I
P
E
LC
P
U
M
P
S
LC
W
E
T
W
E
L
L
PUMP TO BE POSITIONED
RELATIVE TO HATCH
CLEAR OPENING AND
MANUFACTURER'S
REQUIREMENTS
C DISCHARGE
PIPING
LC WET WELL
DISCHARGE PIPING SUPPORT
SEE DETAIL THIS SHEET
INFLUENT SEWER
PSX DIRECT
DRIVE BOOT
L
SEPARATION PER PUMP
AND VALVE
MANUFACTURERS
C DISCHARGE
PIPING
L
L
UT
I
L
I
T
Y
EN
G
I
N
E
E
R
I
N
G
GR
O
U
P
PL
L
C
Te
x
a
s
E
n
g
i
n
e
e
r
i
n
g
F
i
r
m
F
-
1
8
7
1
2
19
1
N
.
U
n
i
o
n
A
v
e
N
E
W
B
R
A
U
N
F
E
L
S
,
T
E
X
A
S
7
8
1
3
0
P
H
:
(
8
3
0
)
2
1
4
-
0
5
2
1
UEG
36
LS-6
DK
PND
PND
LI
F
T
S
T
A
T
I
O
N
P
L
A
N
V
I
E
W
S
H
E
E
T
IH
-
3
5
R
I
A
T
A
L
I
F
T
S
T
A
T
I
O
N
R
E
L
O
C
A
T
I
O
N
A
N
D
OF
F
S
I
T
E
S
E
W
E
R
I
M
P
R
O
V
E
M
E
N
T
S
8032-03
30 January, 2023
1.SAND BLAST AND LINE INTERIOR OF WET WELL TO BE COATED PER CITY OF
SCHERTZ SPECIFICATION OR APPROVED EQUAL (CALCIUM ALUMINATE).
2.THE ACCESS COVERS SHALL BE A MINIMUM OF 48 INCH BY 72 INCH. PUMP SUPPLIER
SHALL PROVIDE DIMENSIONS OF ACCESS OVER THE WET WELL TO ENSURE
COMPATIBILITY WITH SUPPLIED EQUIPMENT. THE ACCESS FRAME AND COVER TO
THE VAULT SHALL BE CONSTRUCTED OF ALUMINUM THREAD PLATE AND SHALL BE
WATERTIGHT (GASKET). THE DOORS SHALL OPEN TO 90° AND AUTOMATICALLY LOCK.
THE LIFTING HANDLES, HANDLES, HINGES AND ALL FASTENING HARDWARE SHALL BE
ALUMINUM OR STAINLESS STEEL, TYPE 316. ACCESS COVER ON VALVE VAULT SHALL
BE A MINIMUM OF 48 INCH BY 72 INCH.
3.PUMP SUPPLIER SHALL PROVIDE DIMENSIONS OF THE 316 STAINLESS STEEL GUIDE
RAILS TO ENSURE COMPATIBILITY WITH SUPPLIED EQUIPMENT. THE PUMP SHALL BE
EASILY REMOVED FOR INSPECTION OR SERVICE. PERSONNEL SHALL HAVE NO
REASON TO ENTER THE WET WELL. GUIDE RAILS SHALL BE SUPPORTED EVERY 10
FEET WITH 316 STAINLESS STEEL SUPPORTS.
4.ALL HARDWARE AND FASTENERS USED SHALL BE CONSTRUCTED OF 316 SERIES
STAINLESS STEEL. GUIDE BRACKETS FOR EACH PUMP MUST BE SUPPLIED BY THE
PUMP MANUFACTURER TO ENSURE COMPATIBILITY WITH SUPPLIED EQUIPMENT.
5.EACH PUMPING UNIT SHALL BE PROVIDED WITH A STAINLESS STEEL LIFTING CHAIN.
LIFTING CHAIN SHALL EXTEND A MINIMUM 10-FT ABOVE WET WELL.
6.A 316 STAINLESS STEEL FLOAT MOUNTING ASSEMBLY SHALL BE PROVIDED. THE
FLOATS SHALL BE MOUNTED AWAY FROM THE WET WELL INLET, ANY CONTROL
WIRING, AND THE PUMPS TO MINIMIZE DISTURBANCE . LEVEL SETTINGS ARE SHOWN
ON THIS SHEET.
7.IN THE WET WELL AND VALVE VAULT ALL STATIONARY PIPING USED SHALL BE CLASS
54 DUCTILE IRON WITH FIELD APPLIED TWO PART EPOXY PAINT COATING. ALL
HARDWARE MUST BE 316 SERIES STAINLESS STEEL WITH ANTI-SEIZE COMPOUND
AND NO PAINT.
8.PUMP/MOTOR DATA
(1 PUMP RUNNING 1 STAND-BY) :
Q= 424 GPM RPM= 3505 RPM
H= 121 FT V= 200V-3 PHASE
HP= 23 HP IMPELLER DIA.= 6 29 32"
9.THE 6" WYE SHALL HAVE 1/4 INCH TAP WITH STAINLESS STEEL OR BRONZE BALL
VALVES. PRESSURE GAUGES SHALL BE INSTALLED (0-100 PSI).
10.IN THE VAULT ALL DISCHARGE LINES SHALL HAVE ADEQUATE THRUST SUPPORT
MEMBERS AT EACH FITTING. WHERE POSSIBLE, LONG RADIUS 90 DEGREE BENDS
SHALL BE USED.
11.THE DISCHARGE LINE FROM EACH PUMP SHALL BE FITTED WITH A CHECK VALVE
AND A PLUG VALVE, WITH THE CHECK VALVE ON THE PUMP SIDE OF THE PLUG
VALVE. WHEN NECESSARY, AIR RELEASE VALVE(S) SHALL BE INSTALLED
DOWNSTREAM OF THE PLUG VALVES.
12.THE VALVE VAULT SHALL BE SIZED LARGE ENOUGH TO PROVIDE AT LEAST 2 FOOT
OF CLEARANCE AROUND ALL APPURTENANCES. THE COVERS SHALL BE ABLE TO BE
SECURED BY A PADLOCK USING A HEAVY DUTY HASP. THE VAULT SHALL BE COATED
WITH THE SAME COATINGS AS THE WET WELL. ALL PIPING SHALL BE COATED WITH
COAL TAR EPOXY.
13.THE VALVE VAULT SHALL HAVE A DRAIN TO THE WET WELL. THE DRAIN SHALL BE A 4
INCH DIAMETER AND BE FITTED WITH A FLAP VALVE OR A BACK-FLOW PREVENTER
AND A TRAP TO PREVENT GASES OR WATER FROM ENTERING THE VALVE VAULT.
THE OPENING TO THE DRAIN SHALL BE COVERED WITH A STAINLESS STEEL SCREEN.
14.BOTTOM OF WET WELL SHALL HAVE A MINIMUM SLOPE OF 10 PERCENT TO THE
PUMP INTAKES AND SHALL HAVE A SMOOTH FINISH.
15.SEAL WET WELL WALL PENETRATIONS WITH NON-SHRINK GROUT AND PSX BOOTS.
16.ALL PIPING, FITTINGS, AND VALVES SHALL BE RESTRAINED.
17.VAULT SHALL HAVE A STAINLESS STEEL SAFETY LADDER INSTALLED AS INDICATED
ON SHEET LS-7. MAXIMUM RUNG SPACING OF 12 INCHES WITH 316 STAINLESS STEEL
HARDWARE AND COATING OR BARRIER BETWEEN DISSIMILAR MATERIALS.
18.CASSION METHOD IS ACCEPTABLE, CONTRACTOR TO DESIGN AND SUBMIT TO
ENGINEER/OWNER, SEE GEOTECHNICAL REPORT FOR SOIL/GROUNDWATER
INFORMATION.
19.ALL ELECTRICAL FOR LIFT STATION TO BE SERVED USING UNDERGROUND ONLY.
20.LATERAL SUPPORT UNISTRUT CHANNEL SIZING:
PIPE SIZE:STRUT SIZE:PLATE SIZE:BOLT SIZE:
4" & 6" 2.5" X 2.5" 6" X 8" 3 8"
21.PRE-CAST WET WELL WALLS SHALL BE WRAPPED. CONTRACTOR SHALL PROVIDE
THE MANUFACTURER'S WRAP SUBMITTAL TO THE CITY FOR REVIEW AND APPROVAL.
WRAPS SHALL BE A MINIMUM OF 9-INCHES WIDE.
STAINLESS STEEL
CABLE GRIPS TO BE
USED FOR FLOATS
(SEE NOTE 5)
HINGED SIDE ROTATED
FOR CLARITY.
316 STAINLESS
STEEL GUIDE RAILS
(SEE NOTE 3)
ALL SECTION JOINTS SHALL BE
SEALED WITH RUBBER GASKETS,
WIPE ALL EXTERIOR JOINTS WITH
NON-SHRINK GROUT. SEE NOTE 21
FLAP
VALVE
VERTICAL RISER
SUPPORT
(SEE NOTE 4)
SLAB ELEV. 785.62
PLACE PSX BOOT
AND NON-SHRINK
GROUT (EACH
END).
6" MIN. DIA. GALVANIZED VENT WITH
MESH 316 SS SCREEN
SEE NOTE 14
FOR CONCRETE
FINISHING
BLOCK-OUT GROUT
FILLET AROUND
STILLING WELL
HIGH LEVEL
ALARM/ INVERT
ALL PUMPS ON
ELEV. 775.90
30
°
3
0
°
SYNKO-FLEX WATERSTOP
UNDER WALL
(SEE STRUCTURAL PLAN SHEET)
ADEKA P-201 WATERSTOP
UNDER WALL
(SEE STRUCTURAL PLAN SHEET)
12-FT DIA. ASTM C-478
PRECAST REINFORCED
CONCRETE WET WELL WITH
RUBBER GASKET JOINTS &
WATERPROOFING
(SEE STRUCTURAL SHEETS)
8" DIA. SDR 26 INLET
(SEE SHEET LS-1 FOR
LOCATION)
INSTALL A 8" DIA. TEE
(ROTATED FOR CLARITY)
INFLUENT ENTRY PSX DIRECT
DRIVE BOOT FILLED WITH
NON-SHRINK GROUT AT EACH END
(TYPICAL)
FOR WET WELL COATING,
SEE NOTE 1 THIS SHEET
SEE STRUCTURAL
CAP SLAB PLAN
SHEET
GROUT BOTTOM TO PUMP
INTAKE, 30° MIN. SLOPE,
FORMED RECTANGULAR
BLOCKOUT AROUND
PUMPS, DIMENSIONS PER
PUMP MANUFACTURER.
316SS PIPE SUPPORTS
AND INTERMEDIATE
GUIDE RAIL BRACKETS
AT 10 FT. MAX SPACING
(SEE NOTE 4)
FLOOR DRAIN
S
C
H
.
8
0
PVC (SEE NOT
E
1
3
)
4" GAS TRAP
STAINLESS
STEEL DRAIN
COVER
SLOPE FLOOR TO
DRAIN AT 1
4" PER 1'
VENT LINE
HINGED SIDE
ROTATED FOR
CLARITY.
DEPTH OF VALVE
VAULT TO BE NO LESS
THAN 4'-0" AND NO
GREATER THAN 6'-0"
2" COMBINATION
AIR/VACUUM RELEASE
VALVE. (A.R.I MODEL D-025
WITH MALE CAM LOCK
OUTLET)
12" MIN. DEPTH WITH
#5 @ 12" T+B.O.C.E.W.
CONCRETE SLAB
(BOLT VALVE VAULT
SLAB)
PROP. CONCRETE VALVE
VAULT W/ LADDER TO BE A
MIN. 9'-5" X 8'-5" INSIDE AREA.
(BOLT VALVE VAULT TO SLAB)
ADJUSTABLE
JACK STAND
SUPPORTS
12" MIN.
2' MIN.
2' MIN.
2' MIN.
2' MIN
1' MIN.
CLEARANCE TO
FLOOR OF
VAULT
SEE
STRUCTURAL
PLAN SHEET
SEE STRUCTURAL PLANS AND
GEOTECHNICAL REPORT FOR
BACKFILL AND EXCAVATION
REQUIREMENTS.
8" DIA. INVERT
ELEV. 776.02
BOTTOM ELEV. 765.00
PUMP ON
ELEV: 771.50
PUMP OFF
ELEV:769.50
ALL PUMPS OFF
ELEV:768.50
EPOXY LINED
DUCTILE
IRON PIPE
C900 DR14
PIPE
VEGA RADAR LEVEL TRANSMITTER MOUNTED IN NEMA
4X 316 SS HINGED BOX SIZED FOR LEVEL TRANSMITTER
IN AN AREA OF THE WET WELL WHICH IS REMOVED
FROM THE EFFECTS OF THE INFLUENT FLOW(S) BEING
RECEIVED AND ACCORDING TO MANUFACTURERS
RECOMMENDATIONS.
8" DIA.
SPOOL PIECE
2' MIN. LENGTH
4" MIN. DIA VALVE
VAULT VENT WITH
MESH 316 SS
SCREEN FLANGED
(SEE SHEET LS-10)
316SS MOUNTING
BRACKETS EVERY
5 FT
MOTOR POWER AND
SENSOR CABLES AND
FULL LENGTH 316SS
LIFTING CHAINS
IH-35 RIATA LIFT STATION DESIGN PUMPS:
SUPPLY 2 ITT FLYGT HIGH EFFICIENCY
SUBMERSIBLE PUMP MODEL NP3153 SH
3~274, 23 HP, 3510 RPM 3 1
8" IMPELLER, NO
EQUIVALENT. INSTALL 2 PUMPS WITH
2 MIX FLUSH VALVES THIS CONTRACT,
AND INSTALL PIPING, RAILS, ETC FOR 2
PUMPS.
6" 90° BEND
6" FLEX COUPLING W/ RESTRAINTS
6" X 4" REDUCER
6" CHECK VALVE (HYDRAULIC DAMPENING)
(VERIFY FLOW DIRECTION WITH
INSPECTOR PRIOR TO INSTALLATION)
6" PLUG VALVE
6" 45° BEND
6" CLASS 54 DUCTILE, LENGTH AS
REQUIRED
6" X 6" WYE
6" TEE
6" PLUG VALVE W/ BOX
6" EMERGENCY BYPASS W/ 316SS QUICK
COUPLER AND PLUG.
(ROTATED FOR CLARITY)
6" CHECK VALVE (HYDRAULIC DAMPENING)
PUMP(S) IN OPERATION
STATION OPERATION TABLES
ACTIONELEVATION
WATER LEVEL
PUMP CONTROL LEVELS
PRIMARY TRANSDUCER - HIGH LEVEL ALARM ALL PUMPS ON
BACKUP FLOAT - HIGH LEVEL ALARM
ALL PUMPS OFF
775.90
PRIMARY TRANSDUCER - PUMP LEVEL PUMP OFF769.50
PUMP ONPRIMARY TRANSDUCER - PUMP LEVEL771.50
768.50
BACKUP FLOAT - LOW LEVEL ALARM
PRIMARY TRANSDUCER - LOW LEVEL ALARM
ALL PUMPS ON
ALL PUMPS OFF
775.90
768.50
PUMP NOTES:
1.CONNECTION BETWEEN PUMP DISCHARGE FLANGE &
DISCHARGE PIPE FLANGE SHALL BE A MACHINED METAL
TO METAL WATER TIGHT CONTACT.
2.NO PORTION OF THE PUMP SHALL BE IN CONTACT WITH
THE FLOOR.
3.PUMPS AND WET WELL LEVEL SHALL BE MONITORED VIA
SCADA
STRUCTURAL NOTES:
1.CONCRETE SLABS AND SUBGRADE FILLING SHALL BE DESIGN
BASED ON THE WET WELL DIMENSIONS, SOIL CONDITIONS, ETC
2.ALL SPOIL MATERIAL TO BE HAULED-OFF SITE.
UT
I
L
I
T
Y
EN
G
I
N
E
E
R
I
N
G
GR
O
U
P
PL
L
C
Te
x
a
s
E
n
g
i
n
e
e
r
i
n
g
F
i
r
m
F
-
1
8
7
1
2
19
1
N
.
U
n
i
o
n
A
v
e
N
E
W
B
R
A
U
N
F
E
L
S
,
T
E
X
A
S
7
8
1
3
0
P
H
:
(
8
3
0
)
2
1
4
-
0
5
2
1
UEG
36
LS-7
DK
PND
PND
LI
F
T
S
T
A
T
I
O
N
P
R
O
F
I
L
E
V
I
E
W
S
H
E
E
T
IH
-
3
5
R
I
A
T
A
L
I
F
T
S
T
A
T
I
O
N
R
E
L
O
C
A
T
I
O
N
A
N
D
OF
F
S
I
T
E
S
E
W
E
R
I
M
P
R
O
V
E
M
E
N
T
S
8032-03
01 February, 2023
1.SAND BLAST AND LINE INTERIOR OF WET WELL TO BE COATED PER CITY OF
SCHERTZ SPECIFICATION OR APPROVED EQUAL (CALCIUM ALUMINATE).
2.THE ACCESS COVERS SHALL BE A MINIMUM OF 48 INCH BY 72 INCH. PUMP SUPPLIER
SHALL PROVIDE DIMENSIONS OF ACCESS OVER THE WET WELL TO ENSURE
COMPATIBILITY WITH SUPPLIED EQUIPMENT. THE ACCESS FRAME AND COVER TO
THE VAULT SHALL BE CONSTRUCTED OF ALUMINUM THREAD PLATE AND SHALL BE
WATERTIGHT (GASKET). THE DOORS SHALL OPEN TO 90° AND AUTOMATICALLY LOCK.
THE LIFTING HANDLES, HANDLES, HINGES AND ALL FASTENING HARDWARE SHALL BE
ALUMINUM OR STAINLESS STEEL, TYPE 316. ACCESS COVER ON VALVE VAULT SHALL
BE A MINIMUM OF 48 INCH BY 72 INCH.
3.PUMP SUPPLIER SHALL PROVIDE DIMENSIONS OF THE 316 STAINLESS STEEL GUIDE
RAILS TO ENSURE COMPATIBILITY WITH SUPPLIED EQUIPMENT. THE PUMP SHALL BE
EASILY REMOVED FOR INSPECTION OR SERVICE. PERSONNEL SHALL HAVE NO
REASON TO ENTER THE WET WELL. GUIDE RAILS SHALL BE SUPPORTED EVERY 10
FEET WITH 316 STAINLESS STEEL SUPPORTS.
4.ALL HARDWARE AND FASTENERS USED SHALL BE CONSTRUCTED OF 316 SERIES
STAINLESS STEEL. GUIDE BRACKETS FOR EACH PUMP MUST BE SUPPLIED BY THE
PUMP MANUFACTURER TO ENSURE COMPATIBILITY WITH SUPPLIED EQUIPMENT.
5.EACH PUMPING UNIT SHALL BE PROVIDED WITH A STAINLESS STEEL LIFTING CHAIN.
LIFTING CHAIN SHALL EXTEND A MINIMUM 10-FT ABOVE WET WELL.
6.A 316 STAINLESS STEEL FLOAT MOUNTING ASSEMBLY SHALL BE PROVIDED. THE
FLOATS SHALL BE MOUNTED AWAY FROM THE WET WELL INLET, ANY CONTROL
WIRING, AND THE PUMPS TO MINIMIZE DISTURBANCE . LEVEL SETTINGS ARE SHOWN
ON THIS SHEET.
7.IN THE WET WELL AND VALVE VAULT ALL STATIONARY PIPING USED SHALL BE CLASS
54 DUCTILE IRON WITH FIELD APPLIED TWO PART EPOXY PAINT COATING. ALL
HARDWARE MUST BE 316 SERIES STAINLESS STEEL WITH ANTI-SEIZE COMPOUND
AND NO PAINT.
8.PUMP/MOTOR DATA
(1 PUMP RUNNING 1 STAND-BY) :
Q= 424 GPM RPM= 3505 RPM
H= 121 FT V= 200V-3 PHASE
HP= 23 HP IMPELLER DIA.= 6 29 32"
9.THE 6" WYE SHALL HAVE 1/4 INCH TAP WITH STAINLESS STEEL OR BRONZE BALL
VALVES. PRESSURE GAUGES SHALL BE INSTALLED (0-100 PSI).
10.IN THE VAULT ALL DISCHARGE LINES SHALL HAVE ADEQUATE THRUST SUPPORT
MEMBERS AT EACH FITTING. WHERE POSSIBLE, LONG RADIUS 90 DEGREE BENDS
SHALL BE USED.
11.THE DISCHARGE LINE FROM EACH PUMP SHALL BE FITTED WITH A CHECK VALVE
AND A PLUG VALVE, WITH THE CHECK VALVE ON THE PUMP SIDE OF THE PLUG
VALVE. WHEN NECESSARY, AIR RELEASE VALVE(S) SHALL BE INSTALLED
DOWNSTREAM OF THE PLUG VALVES.
12.THE VALVE VAULT SHALL BE SIZED LARGE ENOUGH TO PROVIDE AT LEAST 2 FOOT
OF CLEARANCE AROUND ALL APPURTENANCES. THE COVERS SHALL BE ABLE TO BE
SECURED BY A PADLOCK USING A HEAVY DUTY HASP. THE VAULT SHALL BE COATED
WITH THE SAME COATINGS AS THE WET WELL. ALL PIPING SHALL BE COATED WITH
COAL TAR EPOXY.
13.THE VALVE VAULT SHALL HAVE A DRAIN TO THE WET WELL. THE DRAIN SHALL BE A 4
INCH DIAMETER AND BE FITTED WITH A FLAP VALVE OR A BACK-FLOW PREVENTER
AND A TRAP TO PREVENT GASES OR WATER FROM ENTERING THE VALVE VAULT.
THE OPENING TO THE DRAIN SHALL BE COVERED WITH A STAINLESS STEEL SCREEN.
14.BOTTOM OF WET WELL SHALL HAVE A MINIMUM SLOPE OF 10 PERCENT TO THE PUMP
INTAKES AND SHALL HAVE A SMOOTH FINISH.
15.SEAL WET WELL WALL PENETRATIONS WITH NON-SHRINK GROUT AND PSX BOOTS.
16.ALL PIPING, FITTINGS, AND VALVES SHALL BE RESTRAINED.
17.VAULT SHALL HAVE A STAINLESS STEEL SAFETY LADDER INSTALLED AS INDICATED
ON SHEET LS-7. MAXIMUM RUNG SPACING OF 12 INCHES WITH 316 STAINLESS STEEL
HARDWARE AND COATING OR BARRIER BETWEEN DISSIMILAR MATERIALS.
18.CASSION METHOD IS ACCEPTABLE, CONTRACTOR TO DESIGN AND SUBMIT TO
ENGINEER/OWNER, SEE GEOTECHNICAL REPORT FOR SOIL/GROUNDWATER
INFORMATION.
19.ALL ELECTRICAL FOR LIFT STATION TO BE SERVED USING UNDERGROUND ONLY.
20.LATERAL SUPPORT UNISTRUT CHANNEL SIZING:
PIPE SIZE:STRUT SIZE:PLATE SIZE:BOLT SIZE:
4" & 6" 2.5" X 2.5" 6" X 8" 3 8"
21.PRE-CAST WET WELL WALLS SHALL BE WRAPPED. CONTRACTOR SHALL PROVIDE
THE MANUFACTURER'S WRAP SUBMITTAL TO THE CITY FOR REVIEW AND APPROVAL.
WRAPS SHALL BE A MINIMUM OF 9-INCHES WIDE.
DETAIL 1:
SAFETY GRATE DETAILS
GAP BETWEEN ACCESS
HATCH AND SAFETY GRATE
SHALL NOT EXCEED 4"
SAFETY GRATE OPENINGS
SHALL NOT EXCEED 4"
APPLY YELLOW
AND BLACK
THICK COATING
DO
N
O
T
S
T
E
P
O
N
G
R
A
T
E
DO
N
O
T
S
T
E
P
O
N
G
R
A
T
E
DO NOT STEP ON GRATE
PAINT "DO NOT
STEP ON GRATE"
W/RED ACRILYC
PAINT. 5" HIGH
STENCIL LETERS
ALL AROUND
ACCESS HATCH
SAFETY GRATE
HATCH COVER
KEY NOTES:
·SAFETY GRATE SHALL BE UP TO 12" BELOW TOP OF CONCRETE SLAB, BUT IN NO CASE THE
12" DISTANCE SHALL BE EXCEEDED.
·ACCESS HATCH COVER SHALL BE PERFECTLY LEVELED WITH TOP OF CONCRETE SLAB.
·PROVIDE 2 EACH HATCH KEYS.
·HATCH ASSEMBLY SHALL BE RATED FOR 300 PSF LIVE LOAD
DETAIL 7:
LADDER DETAIL
∅
1.LADDER SHALL BE ALL STAINLESS STEEL WELDED CONSTRUCTION AND BE
FLAT WALL MOUNTED
2.LADDER SHALL BE FLOOR AND WALL MOUNTED ACCORDING TO
MANUFACTURE RECOMMENDATIONS (L1D MOUNTING)
3.LENGTH OF LADDER SHALL BE EQUAL TO DEPTH OF VALVE VAULT WITH 6"
CLEARANCE FROM THE BOTTOM ACCESS HATCH.
6"
1.6'
(MN.)
SERIES L1D LADDERS
·
·
·
·
·
·
·
·
·
·
·
(ADVISE)
L1D (FLOOR AND WALL MOUNT)
HALLIDAY PRODUCTS
DETAIL 2:
PIPE SUPPORT DETAILS
SECTION VIEW
CONCRETE ANCHOR
BOLTS (4 TYP) 12"X6"
6"X6"X3 8"
BASE PLATE
FLAT WASHER
AND NUT
SOLIDLY WELDED
ALL AROUND
NOTE:
ALL COMPONENTS SHALL
BE STAINLESS STEEL 316.
212" SCH 40 PIPE
HEIGHT ADJUSTMENT NUT
SUPPORT SHAFT
THREADED
SOLIDLY WELDED
ALL AROUND
PIPE SUPPORT CLAMPS
NEOPRENE GASKET
DISCHARGE PIPE
PLATE DETAIL
TOP SLAB
4X DRILL HOLE
9 16" DIAMETER
3 8" BOLT, NUT
AND WASHER
PRESSURE
GAUGE
1/2" STAINLESS
STEEL 316
BALL VALVE
HEADER
PIPE
NEOPRENE
GASKET
DETAIL 3:
PRESSURE GAUGE INSTALLATION DETAIL
1/2" STAINLESS STEEL 316
THREADED TUBE
KEY NOTES:
·PRESSURE GAUGE SHALL BE
RATED FOR CORROSIVE SERVICE
·4" DIAL SIZE
·GRADE 1A
·LIQUID FILLED
·TYPE 316 STAINLESS STEEL
BOURDON TUBE
·FULL BLOWOUT PROTECTION
·GLASS SAFETY LENS
·GAUGE TO READ IN BOTH FTH20
AND PSI. SELECT RANGE FOR
NORMAL WORKING PRESSURE TO
BE MID-RANGE.
DIAPHRAGM SEAL
FILLED WITH
GLYCERIN
1 /2" FITTINGS, BALL
VALVE, AND PLAIN END
BIBB SAMPLING VALVE
(ALL 316SS)
BRONZE SADDLE WITH
DOUBLE SS STRAPS
BY FORD OR MUELLER
DETAIL 6:
AIR RELEASE VALVE INSTALLATION DETAIL AT HEADER
HEADER
PIPE
NEOPRENE
GASKET
2" GATE VALVE
1/2" BALL
VALVE
1 1/2" PVC SCH
40 AIR BLEED
PIPE
PIPE BACK INTO
WET WELL
2-INCH THREADED TYPE
AUTOMATIC SEWAGE AIR
RELEASE VALVE.
A.R.I. D-025 OR
APPROVED EQUAL
BRONZE SADDLE WITH
DOUBLE SS STRAPS
BY FORD OR MUELLER
SLOPE
A
T
33.33%
(
M
A
X
.
)
SLOPE
A
T
33.33%
(
M
A
X
.
)
SEE PLAN
SPECIFICATIONS:
1. 10" COMPACTED BASE PER GEOTECHNICAL RECOMMENDATIONS.
2. ASPHALT SHALL BE 3" TYPE "D".
3. SUBGRADE COMPACTED TO A MIN. OF 6" AND SHALL BE MOISTURE CONDITIONED PER GEOTECHNICAL
RECOMMENDATIONS.
DETAIL 5:
ASPHALT PAVING DETAIL
6" COMPACTED SUBGRADE W/
GEOGRID
3" HMAC
9" CONCRETE
FLUSH CURB
12"12"
10" FLEXIBLE BASE
UT
I
L
I
T
Y
EN
G
I
N
E
E
R
I
N
G
GR
O
U
P
PL
L
C
Te
x
a
s
E
n
g
i
n
e
e
r
i
n
g
F
i
r
m
F
-
1
8
7
1
2
19
1
N
.
U
n
i
o
n
A
v
e
N
E
W
B
R
A
U
N
F
E
L
S
,
T
E
X
A
S
7
8
1
3
0
P
H
:
(
8
3
0
)
2
1
4
-
0
5
2
1
UEG
36
LS-8
DK
PND
PND
WE
T
W
E
L
L
A
N
D
P
I
P
I
N
G
D
E
T
A
I
L
S
S
H
E
E
T
1
O
F
3
IH
-
3
5
R
I
A
T
A
L
I
F
T
S
T
A
T
I
O
N
R
E
L
O
C
A
T
I
O
N
A
N
D
OF
F
S
I
T
E
S
E
W
E
R
I
M
P
R
O
V
E
M
E
N
T
S
8032-03
30 January, 2023
DETAIL 11:
HOSE BIB DETAIL
36"
6"
WATERLINE
SEE SITE PLAN
36" MIN
COVER 1" SCH 80
PVC
1" WOODFORD Y1 YARD
HYDRANT WITH HOSE
AND ACCESSORIES
NOTE:
1" WOODFORD Y1 NON-FREEZE YARD HYDRANT WITH 50FT
HEAVY DUTY RUBBER HOSE, BRASS ADJUSTABLE SPRAY
NOZZLE, AND MCMASTER-CARR 53325K33 HOSE RACK
1'-6"
3/4" WELDED STEEL LOOP
1" INNER RADIUS
6" SCH 80 STEEL PIPE
(PAINTED YELLOW)
CAST IRON SLEEVE
SET IN CONCRETE
FINISHED GRADE
4'-0"
4"
12"
12"
12"
8"
1'-6"
4'-0"3,000 PSI CONCRETE BASE
4-4' #4
#4-12" O.C.
12"
TOP VIEW
DETAIL 8:
REMOVABLE BOLLARD DETAIL - NTS
NOT TO SCALE
9"
18"
(1") DIA. SMOOTH DOWEL
9"3/4" REMOLDED
EXP. JOINT MATL.
REBAR - PER
CONCRETE PAVING
DETAIL
1" MIN.
CLEARANCE
CONCRETE PAVING EXPANSION JOINT DETAIL
26 GAUGE
PLASTIC TUBE
1" MIN.
CLEARANCE
1/4"
CONCRETE PAVING CONCRETE JOINT DETAIL
TABLE 1
PAVEMENT
THICKNESS
(IN)
4 1/2
5
6
7
8
9
10
11
12
DOWEL SIZES AND SPACINGS
DIAMETER
(IN)
1/2
1/2
3/4
1
1
1 1/4
1 1/4
1 1/4
1 1/4
LENGTH
(IN)
18
18
18
18
18
18
18
18
18
SPACING
(IN)
12
12
12
12
12
12
12
12
12
DETAIL 9:
NOT TO SCALE
DETAIL 10:
TYPICAL EXTERIOR EQUIPMENT PAD - NTS
@ 12"C/C,
2'-0"
4x
8"8"
6"
MIN.
6"
6"
2"
CLR.
6" MAX.
1'-0"
3"
CLR.
ALTERNATE DIRECTION
OF 2'-0" LEG
3/4" CHAMFER
FINISH GRADE, SLOPE
AWAY FROM PAD
#4 CONT, T&B AT
PERIMETER. HOOK
ENDS AT CORNERS
BASE OF
EQUIPMENT 6" COMPACTED
CRUSHED LIMESTONE
BASE MATERIAL
#4 @ 12"C/C, EW
5'-0"
COMPACTED
SELECT FILL
CONCRETE
SLAB-ON-GRADE
#4 CONT, T&B,
W/STD HOOK AT
ENDS
#
PROVIDE INTERIOR BEAM
AS SHOWN ON PLAN OR
@ 20'-0" MAX CENTERS.
INTERIOR BEAMS ARE
REQUIRED IF OVERALL
PAD DIMENSION IS 20'-0"
OR GREATER
UT
I
L
I
T
Y
EN
G
I
N
E
E
R
I
N
G
GR
O
U
P
PL
L
C
Te
x
a
s
E
n
g
i
n
e
e
r
i
n
g
F
i
r
m
F
-
1
8
7
1
2
19
1
N
.
U
n
i
o
n
A
v
e
N
E
W
B
R
A
U
N
F
E
L
S
,
T
E
X
A
S
7
8
1
3
0
P
H
:
(
8
3
0
)
2
1
4
-
0
5
2
1
UEG
36
LS-9
DK
PND
PND
WE
T
W
E
L
L
A
N
D
P
I
P
I
N
G
D
E
T
A
I
L
S
S
H
E
E
T
2
O
F
3
IH
-
3
5
R
I
A
T
A
L
I
F
T
S
T
A
T
I
O
N
R
E
L
O
C
A
T
I
O
N
A
N
D
OF
F
S
I
T
E
S
E
W
E
R
I
M
P
R
O
V
E
M
E
N
T
S
8032-03
30 January, 2023
DETAIL 18:
LIFT STATION GATE
HE
I
G
H
T
8
'
-
0
"
GATE WIDTH TO
MATCH PLANS
18"
MAX. SPACING
2 DROP RODS
3" x 3" SQUARE
STEEL FRAMES
4" x 4" SQUARE STEEL
CORNER POSTS
CHAIN AND LOCK TO
BE PROVIDED BY
CONTRACTOR,
COORDINATE WITH
OWNER PRIOR TO
CONSTRUCTION
PROVIDE
OPENING FOR
CHAIN LOCK
SOLID METAL
PRIVACY PANEL
GATE, COLOR TO
BE BLACK
TO HOSE BIB
1-1/2" REDUCED PRESSURE DOUBLE
CHECK BACKFLOW PREVENTER (DEVICE
SHOWN ROTATED) PROVIDE CONCRETE
SUPPORT FOR THE DEVICE
NOTES:
1.INSTALL BACKFLOW ASSEMBLY IN ACCORDANCE WITH THE LOCAL PLUMBING CODE
2.CONTRACTOR SHALL COORDINATE LOCATION OF DEVICE PRIOR TO WATER MAIN
CONSTRUCTION
3.INSTALL TYPE "K" RIGID COPPER PIPING TO 5' ON EACH SIDE OF CONCRETE PAD
BEFORE CONNECTING TO WATER SERVICE LINES.
4.INSTALL TYPE "K" RIGID COPPER PIPING, USE 90° ELBOWS TURNING UP INTO
BACKFLOW DEVICE PAD DO NOT BEND PIPING BRAZE ALL METALLIC CONNECTIONS
OF THE COPPER PIPE
INSULATED ALUMINUM ENCLOSURE SIZE
AS REQUIRED FASTEN TO CONCRETE
SLAB WITH STAINLESS STEEL HARDWARE
#3@18" E.W.
6" CONC
SLAB
COPPER
PIPING TYP
PIPE INSULATION
TYP
PVC SLEEVE TYP UNION
POINT OF CONNECTION
1-1/2" BALL VALVE
4"
DETAIL 12:
BACKFLOW PREVENTER ASSEMBLY DETAIL
DETAIL 15:
PIPE SUPPORT DETAIL
1 1/2" GROUT
8"x8"x1/2" FLAT
PLATE W/ (4 REQ'D)
5/8" HOLES
(316 STAINLESS
STEEL)DISCHARGE PIPE
SIZE VARIES D.I.P.
1/2"x4" 316
STAINLESS
STEEL ANCHOR
BOLT (4 REQ'D)
3"x4"x1/2" 316
STAINLESS
STEEL ANCHOR
DETAIL 14:
VENT PIPE DETAIL
GALVANIZED VENT PIPE
(SIZE PER PLANS)
20 MESH STAINLESS
STEEL 316 SCREEN
TO BE INSTALLED
BETWEEN FLANGES
CONCRETE SLAB
24"
NOTE:
WET WELL VENT (SIZE PER PLAN), GALVANIZED
GOOSENECK PIPE WITH WELDED WATERSTOP RING,
FLANGED, 20 MESH 316SS SCREEN 24'' AFF, CAST IN
PLACE.
DETAIL 17:
PIPE PENETRATION DETAIL
TO PUMP
WITHIN
WET WELL
OUTSIDE
WET WELL
SEAL DISCHARGE
PIPE WITH 316 SS
LINK SEAL
WET WELL
TOP SLAB
UT
I
L
I
T
Y
EN
G
I
N
E
E
R
I
N
G
GR
O
U
P
PL
L
C
Te
x
a
s
E
n
g
i
n
e
e
r
i
n
g
F
i
r
m
F
-
1
8
7
1
2
19
1
N
.
U
n
i
o
n
A
v
e
N
E
W
B
R
A
U
N
F
E
L
S
,
T
E
X
A
S
7
8
1
3
0
P
H
:
(
8
3
0
)
2
1
4
-
0
5
2
1
UEG
DETAIL 13:
HATCH LAYOUT
36
LS-10
DK
PND
PND
WE
T
W
E
L
L
A
N
D
P
I
P
I
N
G
D
E
T
A
I
L
S
S
H
E
E
T
3
O
F
3
IH
-
3
5
R
I
A
T
A
L
I
F
T
S
T
A
T
I
O
N
R
E
L
O
C
A
T
I
O
N
A
N
D
OF
F
S
I
T
E
S
E
W
E
R
I
M
P
R
O
V
E
M
E
N
T
S
8032-03
30 January, 2023
UT
I
L
I
T
Y
EN
G
I
N
E
E
R
I
N
G
GR
O
U
P
PL
L
C
Te
x
a
s
E
n
g
i
n
e
e
r
i
n
g
F
i
r
m
F
-
1
8
7
1
2
19
1
N
.
U
n
i
o
n
A
v
e
N
E
W
B
R
A
U
N
F
E
L
S
,
T
E
X
A
S
7
8
1
3
0
P
H
:
(
8
3
0
)
2
1
4
-
0
5
2
1
UEG
36
LS-11
DK
PND
PND
FL
A
T
W
O
R
K
D
E
T
A
I
L
S
IH
-
3
5
R
I
A
T
A
L
I
F
T
S
T
A
T
I
O
N
R
E
L
O
C
A
T
I
O
N
A
N
D
OF
F
S
I
T
E
S
E
W
E
R
I
M
P
R
O
V
E
M
E
N
T
S
8032-03
30 January, 2023
L:
\
E
n
g
i
n
e
e
r
\
S
t
a
n
d
a
r
d
D
e
t
a
i
l
s
a
n
d
T
e
c
h
n
i
c
a
l
S
p
e
c
i
f
i
c
a
t
i
o
n
s
\
S
t
a
n
d
a
r
d
D
e
t
a
i
l
s
\
2
0
1
9
\
D
R
A
I
N
A
G
E
&
E
N
V
I
R
O
N
M
E
N
T
A
L
\
D
R
A
I
N
A
G
E
A
N
D
E
N
V
I
R
O
N
M
E
N
T
A
L
D
E
T
A
I
L
S
5
.
2
0
1
9
.
d
w
g
SILT FENCE
ENGINEERING AND PUBLIC WORKS DSGN. BY:
SCALE:
ENG.DRAWN BY:BCP
DATE:
SHEET NO.:
5/15/19
1
Maintain minimum
roadway widths of 30 feet.
Temporary pipe culvert
as needed
or four times the circumference
of the largest construction vehicle tire,
whichever is greater
STABILIZED CONSTRUCTION EXIT
ENGINEERING AND PUBLIC WORKS DSGN. BY:
SCALE:
ENG.DRAWN BY:BCP
DATE:
SHEET NO.:
5/15/19
1
L:\E
n
g
i
n
e
e
r
\
S
t
a
n
d
a
r
d
D
e
t
a
i
l
s
a
n
d
T
e
c
h
n
i
c
a
l
S
p
e
c
i
f
i
c
a
t
i
o
n
s
\
S
t
a
n
d
a
r
d
D
e
t
a
i
l
s
\
2
0
1
9
\
D
R
A
I
N
A
G
E
&
E
N
V
I
R
O
N
M
E
N
T
A
L
\
D
R
A
I
N
A
G
E
A
N
D
E
N
V
I
R
O
N
M
E
N
T
A
L
D
E
T
A
I
L
S
5
.
2
0
1
9
.
d
w
g
CONCRETE COLLAR PER
MANHOLE RING ENCASEMENT
DETAIL
WATERTIGHT MANHOLE RING AND COVER
SEE DETAILS FOR RING & COVER
A MINIMUM OF TWO AND A
MAXIMUM OF FOUR GRADE
RINGS SHALL BE USED AT
EACH MANHOLE.
RESILIENT CONNECTOR
(TYPICAL)
CONCRETE GROUT
#4 BARS @ 12" O.C. EACH WAY 8"
MIN
MANHOLE
ENGINEERING AND PUBLIC WORKS DSGN. BY:
SCALE:
ENG.DRAWN BY:BCP
DATE:
SHEET NO.:
5/10/19
1
L:
\
E
n
g
i
n
e
e
r
\
S
t
a
n
d
a
r
d
D
e
t
a
i
l
s
a
n
d
T
e
c
h
n
i
c
a
l
S
p
e
c
i
f
i
c
a
t
i
o
n
s
\
S
t
a
n
d
a
r
d
D
e
t
a
i
l
s
\
2
0
1
9
\
W
W
\
S
T
A
N
D
A
R
D
S
E
W
E
R
D
E
T
A
I
L
S
0
4
_
2
0
1
9
.
d
w
g
L:
\
E
n
g
i
n
e
e
r
\
S
t
a
n
d
a
r
d
D
e
t
a
i
l
s
a
n
d
T
e
c
h
n
i
c
a
l
S
p
e
c
i
f
i
c
a
t
i
o
n
s
\
S
t
a
n
d
a
r
d
D
e
t
a
i
l
s
\
2
0
1
9
\
W
W
\
S
T
A
N
D
A
R
D
S
E
W
E
R
D
E
T
A
I
L
S
0
4
_
2
0
1
9
.
d
w
g
CLASS "B" CONCRETE
MANHOLE RING ENCASEMENT
ENGINEERING AND PUBLIC WORKS DSGN. BY:
SCALE:
ENG.DRAWN BY:BCP
DATE:
SHEET NO.:
5/10/19
1
L:
\
E
n
g
i
n
e
e
r
\
S
t
a
n
d
a
r
d
D
e
t
a
i
l
s
a
n
d
T
e
c
h
n
i
c
a
l
S
p
e
c
i
f
i
c
a
t
i
o
n
s
\
S
t
a
n
d
a
r
d
D
e
t
a
i
l
s
\
2
0
1
9
\
W
W
\
S
T
A
N
D
A
R
D
S
E
W
E
R
D
E
T
A
I
L
S
0
4
_
2
0
1
9
.
d
w
g
L:
\
E
n
g
i
n
e
e
r
\
S
t
a
n
d
a
r
d
D
e
t
a
i
l
s
a
n
d
T
e
c
h
n
i
c
a
l
S
p
e
c
i
f
i
c
a
t
i
o
n
s
\
S
t
a
n
d
a
r
d
D
e
t
a
i
l
s
\
2
0
1
9
\
D
R
A
I
N
A
G
E
&
E
N
V
I
R
O
N
M
E
N
T
A
L
\
D
R
A
I
N
A
G
E
A
N
D
E
N
V
I
R
O
N
M
E
N
T
A
L
D
E
T
A
I
L
S
5
.
2
0
1
9
.
d
w
g
TREE AND PLANT PROTECTION
ENGINEERING AND PUBLIC WORKSSCALE:
DSGN. BY:ENG.DRAWN BY:BCP
DATE:
SHEET NO.:
5/15/19
1
1 1/4" SHARP FACE
GOTHIC
(6) 1" DIA HOLES
ON A 37" B.C.
(2) EPIC PICKBARS®
(4) 1/2"-13 SS HX HD BLTS
WITH STEEL & RUBBER WASHERS
32" DIA [813mm]1 1/2"
[38mm]
2 1/4"
[57mm]
23" DIA [584mm]
COVER SECTION
32 3/16" DIA [818mm]
1/4" DIA
NEOPRENE GASKET
4 1/2"
[114mm]
30" DIA [762mm]
33 7/8" DIA [860mm]
40 3/4" DIA [1035mm]
FRAME SECTION
5/8"
[16mm]
3/4" DIA [19mm]
BOLTING DETAIL
1 9/16"
[40mm]
1 5/8" DIA [41mm]
MANHOLE
RING & COVER
ENGINEERING AND PUBLIC WORKS DSGN. BY:
SCALE:
ENG.DRAWN BY:BCP
DATE:5/10/19
SHEET NO.: 2 of 2
S R
R
A E
N WIETSARY
PROD
N
O
.
ZCTITEYCOFS
H
L:
\
E
n
g
i
n
e
e
r
\
S
t
a
n
d
a
r
d
D
e
t
a
i
l
s
a
n
d
T
e
c
h
n
i
c
a
l
S
p
e
c
i
f
i
c
a
t
i
o
n
s
\
S
t
a
n
d
a
r
d
D
e
t
a
i
l
s
\
2
0
1
9
\
W
W
\
S
T
A
N
D
A
R
D
S
E
W
E
R
D
E
T
A
I
L
S
0
4
_
2
0
1
9
.
d
w
g
UT
I
L
I
T
Y
EN
G
I
N
E
E
R
I
N
G
GR
O
U
P
PL
L
C
Te
x
a
s
E
n
g
i
n
e
e
r
i
n
g
F
i
r
m
F
-
1
8
7
1
2
19
1
N
.
U
n
i
o
n
A
v
e
N
E
W
B
R
A
U
N
F
E
L
S
,
T
E
X
A
S
7
8
1
3
0
P
H
:
(
8
3
0
)
2
1
4
-
0
5
2
1
UEG
36
DE
T
A
I
L
S
1
O
F
3
IH
-
3
5
R
I
A
T
A
L
I
F
T
S
T
A
T
I
O
N
R
E
L
O
C
A
T
I
O
N
A
N
D
OF
F
S
I
T
E
S
E
W
E
R
I
M
P
R
O
V
E
M
E
N
T
S
TACK COAT BETWEEN
EXISTING AND NEW
PAVEMENT
VERTICAL
SAWCUT
PAVEMENT SURFACE COURSE
(3" HMAC TYPE "D" MIN) OR
MATCH EXISTING
PAVEMENT & BASE MATERIAL
PER GEOTECHNICAL DESIGN
12" MARKING TAPE
14 GA. SOLID DETECTION
WIRE TAPED TO PIPE
(FORCE MAINS ONLY)
INITIAL BACKFILL
MAIN IN TRENCH
ENGINEERING AND PUBLIC WORKS DSGN. BY:
SCALE:
ENG.DRAWN BY:BCP
DATE:
SHEET NO.:
5/10/19
1
L:
\
E
n
g
i
n
e
e
r
\
S
t
a
n
d
a
r
d
D
e
t
a
i
l
s
a
n
d
T
e
c
h
n
i
c
a
l
S
p
e
c
i
f
i
c
a
t
i
o
n
s
\
S
t
a
n
d
a
r
d
D
e
t
a
i
l
s
\
2
0
1
9
\
W
W
\
S
T
A
N
D
A
R
D
S
E
W
E
R
D
E
T
A
I
L
S
0
4
_
2
0
1
9
.
d
w
g
LIMITS
6" MIN
6" MIN O.D.
PAY
LIMITS
1'
MIN
1'
MIN
PAY
O.D.
6" MIN #4 BARS
PAY
PAY
LIMITS
CLASS "B"
CONCRETE
COVER
BEDDING
PAY
LIMITS
6" MIN
6" MIN
VARIES
LIMITS
LIMITS
6" MIN
6" MIN
PAY
LIMITS
PAY
LIMITS
6" MIN6" MIN
PRECAST CRADLE BLOCK
OR APPROVED SUBSTITUTE
6" MIN
PAY
TIE DOWN WIRING
TO PREVENT
FLOTATION
LIMITS
O.D.
PAY
VARIES
6"
O.D.MIN
SEWER PIPE
CONCRETE ENCASEMENT
ENGINEERING AND PUBLIC WORKS DSGN. BY:
SCALE:
ENG.DRAWN BY:BCP
DATE:
SHEET NO.:
5/10/19
1
L:
\
E
n
g
i
n
e
e
r
\
S
t
a
n
d
a
r
d
D
e
t
a
i
l
s
a
n
d
T
e
c
h
n
i
c
a
l
S
p
e
c
i
f
i
c
a
t
i
o
n
s
\
S
t
a
n
d
a
r
d
D
e
t
a
i
l
s
\
2
0
1
9
\
W
W
\
S
T
A
N
D
A
R
D
S
E
W
E
R
D
E
T
A
I
L
S
0
4
_
2
0
1
9
.
d
w
g
1/4" DIA
ROUND OFF CORNERS
RING MADE FROM
1/2" STEEL PLATE
TRIM ENDS OF
ANGLES TO FIT
WELD TOGETHER MARK O.D.
DEFLECTION TESTING MANDREL
ENGINEERING AND PUBLIC WORKS DSGN. BY:
SCALE:
ENG.DRAWN BY:BCP
DATE:
SHEET NO.:
5/10/19
1
L:
\
E
n
g
i
n
e
e
r
\
S
t
a
n
d
a
r
d
D
e
t
a
i
l
s
a
n
d
T
e
c
h
n
i
c
a
l
S
p
e
c
i
f
i
c
a
t
i
o
n
s
\
S
t
a
n
d
a
r
d
D
e
t
a
i
l
s
\
2
0
1
9
\
W
W
\
S
T
A
N
D
A
R
D
S
E
W
E
R
D
E
T
A
I
L
S
0
4
_
2
0
1
9
.
d
w
g
FINISHED GROUND
PROPOSED WATER LINE
9' MIN
SEE TCEQ RULES ON SEPARATION DISTANCES
OSHA TRENCH SAFETY
ENGINEERING AND PUBLIC WORKS DSGN. BY:
SCALE:
ENG.DRAWN BY:BCP
DATE:
SHEET NO.: X XXX
5/10/19
of
L:
\
E
n
g
i
n
e
e
r
\
S
t
a
n
d
a
r
d
D
e
t
a
i
l
s
a
n
d
T
e
c
h
n
i
c
a
l
S
p
e
c
i
f
i
c
a
t
i
o
n
s
\
S
t
a
n
d
a
r
d
D
e
t
a
i
l
s
\
2
0
1
9
\
W
W
\
S
T
A
N
D
A
R
D
S
E
W
E
R
D
E
T
A
I
L
S
0
4
_
2
0
1
9
.
d
w
g
L:
\
E
n
g
i
n
e
e
r
\
S
t
a
n
d
a
r
d
D
e
t
a
i
l
s
a
n
d
T
e
c
h
n
i
c
a
l
S
p
e
c
i
f
i
c
a
t
i
o
n
s
\
S
t
a
n
d
a
r
d
D
e
t
a
i
l
s
\
2
0
1
9
\
W
W
\
S
T
A
N
D
A
R
D
S
E
W
E
R
D
E
T
A
I
L
S
0
4
_
2
0
1
9
.
d
w
g
OSHA TRENCH SAFETY
ENGINEERING AND PUBLIC WORKS DSGN. BY:
SCALE:
ENG.DRAWN BY:BCP
DATE:
SHEET NO.:
5/10/19
1
UT
I
L
I
T
Y
EN
G
I
N
E
E
R
I
N
G
GR
O
U
P
PL
L
C
Te
x
a
s
E
n
g
i
n
e
e
r
i
n
g
F
i
r
m
F
-
1
8
7
1
2
19
1
N
.
U
n
i
o
n
A
v
e
N
E
W
B
R
A
U
N
F
E
L
S
,
T
E
X
A
S
7
8
1
3
0
P
H
:
(
8
3
0
)
2
1
4
-
0
5
2
1
UEG
36
DE
T
A
I
L
S
2
O
F
3
IH
-
3
5
R
I
A
T
A
L
I
F
T
S
T
A
T
I
O
N
R
E
L
O
C
A
T
I
O
N
A
N
D
OF
F
S
I
T
E
S
E
W
E
R
I
M
P
R
O
V
E
M
E
N
T
S
REMOVE AND DISPOSE
OF THE CONE SECTION
AND LID AS DIRECTED
BY THE ENGINEER OR
DESIGNATED
REPRESENTATIVE
REVEGETATE WITH
"SEEDING FOR EROSION
CONTROL"
"CASTING ADJUSTMENT"
REPAIRS AROUND MANHOLE
FOR MISCELLANEOUS
OUTSIDE R.O.W.
BACKFILL WITH CLASS C
(TOPSOIL)
BORROW AND
COMPACTED
TO 95% DENSITY.
OUTSIDE R.O.W.
CLASS B
BACKFILL WITH
BORROW AND
INSIDE R.O.W.
BACKFILL WITH
FLOWABLE FILL
TO 95% DENSITY.
COMPACTED
EXISTING PIPE.
CUT AND PLUG
SEE NOTE BELOW.
CUT AND PLUG
EXISTING PIPE.
SEE NOTE BELOW.
2'-0''
2'-0''
NOTE:
THE PLUG SHOULD BE COMPOSED OF A MATERIAL SIMILAR TO THE EXISTING PIPE AS
INSTRUCTED BY THE ENGINEER OR DESIGNATED REPRESENTATIVE.
ABANDONED MANHOLE DETAIL
UT
I
L
I
T
Y
EN
G
I
N
E
E
R
I
N
G
GR
O
U
P
PL
L
C
Te
x
a
s
E
n
g
i
n
e
e
r
i
n
g
F
i
r
m
F
-
1
8
7
1
2
19
1
N
.
U
n
i
o
n
A
v
e
N
E
W
B
R
A
U
N
F
E
L
S
,
T
E
X
A
S
7
8
1
3
0
P
H
:
(
8
3
0
)
2
1
4
-
0
5
2
1
UEG
36
DE
T
A
I
L
S
3
O
F
3
IH
-
3
5
R
I
A
T
A
L
I
F
T
S
T
A
T
I
O
N
R
E
L
O
C
A
T
I
O
N
A
N
D
OF
F
S
I
T
E
S
E
W
E
R
I
M
P
R
O
V
E
M
E
N
T
S
B
E
C-1
LA
CAP
DELTA
WYE
"F"
LEGEND & GENERAL NOTES:
1.BRANCH CIRCUIT NUMBERS MAY BE SHOWN NEXT TO SYMBOLS IN MULTIWIRE
CIRCUITS.
2.SYMBOL SIZE DOES NOT IMPLY EQUIPMENT SIZE UNLESS OTHERWISE NOTED.
3.LOWER CASE LETTERS NEXT TO SYMBOLS INDICATE FIXTURE(S) CONTROLLED
BY THE SWITCH DISPLAYING THE SAME LETTER.
4.THIS IS A STANDARD LEGEND LIST. ALL SYMBOLS MAY NOT BE USED.
5.INSTALLATION SHALL BE PER LATEST VERSION OF NATIONAL ELECTRICAL
CODE, CITY OF SCHERTZ REQUIREMENTS, AND ALL APPLICABLE LOCAL
CODES/ORDINANCES. NOT ALL CODE AND STANDARD REQUIREMENTS MAY BE
SHOWN ON PLANS. CONTRACTOR SHALL ADHERE TO CODES AND STANDARDS
REGARDLESS OF BEING SHOWN ON PLANS OR SPECIFICATIONS IN DETAILED
FASHION.
6.REFER TO SPECIFICATIONS AND ENTIRE DRAWING PACKAGE PRIOR TO BID FOR
FULL PROJECT REQUIREMENTS.
EQUIPMENT CONNECTION
JUNCTION OR CONNECTION BOX
STARTER OR LIGHTING CONTACTOR
DISCONNECT
MANHOLE
HANDHOLE
KEYED NOTE. NUMBER MATCHES NOTE NUMBER
TOGGLE SWITCH, WALL MOUNTED, SINGLE POLE SINGLE
THROW. MOUNTED 54" AFF UNLESS OTHERWISE NOTED
TOGGLE SWITCH, WALL MOUNTED, FOUR WAY. MOUNTED 54"
AFF UNLESS OTHERWISE NOTED
SWITCH MOTOR RATED WITH TERMINAL OVERLOADS
OCCUPANCY SENSOR
TERMINAL BOARD
TELEPHONE OUTLET, PRIVATE. MOUNTED 12" AFF
DATA OUTLET, SURFACE MOUNTED
MOTOR LOAD, NUMBER INDICATES HORSEPOWER
POLE
TRANSFORMER, DRY TYPE, KVA RATING MAY BE DISPLAYED
NEXT TO SYMBOL
ANTENNA
HOMERUN. LETTERS INDICATE PANELBOARD, NUMBERS
INDICATE CIRCUIT NUMBER IN PANELBOARD
CONDUIT CAPPED FOR FUTURE USE
CONDUIT GOING DOWN
CONDUIT GOING UP
CONDUIT ABOVE GROUND
CONDUIT RUN UNDERGROUND OR CONCEALED
CONDUIT BELOW GRADE
LIQUID TIGHT FLEXIBLE CONDUIT
SURFACE MOUNT
120V RECEPTACLE FLUSH MOUNTED
120V RECEPTACLE SURFACE MOUNTED
120V QUAD RECEPTACLE FLUSH MOUNTED
120V QUAD RECEPTACLE SURFACE MOUNTED
208V RECEPTACLE FLUSH MOUNTED
208V RECEPTACLE SURFACE MOUNTED
WELDING OUTLET
THERMOSTAT
PANELBOARD FLUSH MOUNTED
PANELBOARD SURFACE MOUNTED
NORTH ARROW
TORQUE SWITCH
SOLENOID SWITCH
LIMIT SWITCH
AMMETER SWITCH
VOLTMETER SWITCH
PRESSURE SWITCH
LIGHTING CONTACTOR
PHOTO CELL
GROUND CONNECTION
NORMALLY OPEN RELAY OR CONTACTOR CONTACTS
NORMALLY CLOSED RELAY OR CONTACTOR CONTACTS
CONDUCTOR CONNECTION
CIRCUIT BREAKER, MOLDED CASE, TRIP CURRENT AND QUANTITY
OF POLES (P) SHOWN NEXT TO SYMBOL
DISCONNECT SWITCH NON-FUSED, LOAD BREAK. CONTINUOUS
CURRENT RATING, QUANTITY OF POLES (P) SHOWN NEXT TO
SYMBOL
DISCONNECT SWITCH FUSED, LOAD BREAK. OCNTINUOUS
CURRENT RATING, QUANTITY OF POLES (P), AND FUSE RATING
SHOWN NEXT TO SYMBOL
FUSE. RATING SHOWN NEXT TO SYMBOL
MOTOR STARTER THERMAL OVERLOAD PROTECTOR
CONTACTOR OR RELAY COIL. LETTERS AND NUMBERS MATCH
CONTACTS CONTROLLED
LIMIT SWITCH NORMALLY CLOSED
LIMIT SWITCH NORMALLY OPEN
MOTOR OPERATED VALVE GEARED LIMIT SWITCH
PRESSURE SWITCH NORMALLY CLOSED OPEN ON INCREASING
PRESSURE
PRESSURE SWITCH NORMALLY OPEN CLOSES ON INCREASING
PRESSURE
LEVEL SWITCH NORMALLY CLOSED OPEN ON INCREASING LEVEL
LEVEL SWITCH NORMALLY OPEN CLOSES ON INCREASING LEVEL
FLOW SWITCH NORMALLY CLOSED OPENS WITH FLOW
FLOW SWITCH NORMALLY OPEN CLOSES ON LOSS OF FLOW
SPACE HEATER
PHASE FAILURE RELAY
MAINTAINED CONTACT START/STOP PUSHBUTTON
MAINTAINED CONTACT HAND-OFF-AUTO SELECTOR SWITCH
NORMALLY CLOSED MOMENTARY CONTACT PUSHBUTTON
NORMALLY OPEN MOMENTARY CONTACT PUSHBUTTON
WYE TRANSFORMER CONNECTION
DELTA TRANSFORMER CONNECTION
CURRENT TRANSFORMER WITH RATIO SHOWN
ANALYTICAL TRANSMITTER
FLOW OR FLOAT SWITCH
LEVEL TRANSMITTER
MOTOR OPERATED VALVE
PRESSURE TRANSMITTER
SOLENOID VALVE
ELAPSED TIME METER
TIME DELAY RELAY. TIMES OUT AFTER ENERGIZATION.
ADJUSTABLE TIME DELAY TIME INDICATED NEXT TO SYMBOL
TIME DELAY RELAY. TIMES OUT AFTER DE-ENERGIZATION.
ADJUSTABLE TIME DELAY TIME INDICATED NEXT TO SYMBOL
CONDUIT TAG
TELEVISION CAMERA
TORQUE SWITCH
PILOT LIGHT R=RED, B=BLUE, G=GREEN, A=AMBER, Y=YELLOW
CONTROL POWER TRANSFORMER. PRIMARY AND SECONDARY
VOLTAGE INDICATED
TERMINAL BLOCK
PLAN LEGEND ONE-LINE AND CONTROL SCHEMATIC LEGEND
INSTRUMENT TRANSFORMER PT=POTENTIAL TRANSFORMER
PT=POWER TRANSFORMER. VOLTAGE AND KVA RATING AS SHOWN
LIGHTING ARRESTOR
SURGE CAPACITOR
AMMETER
VOLTMETER
AMMETER SWITCH
VOLTMETER SWITCH
MOTOR STARTER FVNR=FULL VOLTAGE NON-REVERSING
VFD=VARIABLE FREQUENCY DRIVE
RVSS=REDUCED VOLTAGE SOFT START
RVNR=REDUCED VOLTAGE NON-REVERSING
FVR=FULL VOLTAGE REVERSING
MCP=MOTOR CIRCUIT PROTECTOR
SIZE=NEMA STARTER SIZE
A = GROUNDING RECEPTACLE, B = GROUND TEST WELL
BARE COPPER GROUNDING CONDUCTOR
GROUNDING CONNECTION
COPPER CLAD GROUND ROD
GROUNDING LEGEND
LETTER IN OR BESIDE FIXTURE IDENTIFIES FIXTURE IN FIXTURE
SCHEDULE
LED STRIP LIGHT
LED STRIP LIGHT WITH BATTER BACKUP
LED FIXTURE, SURFACE OR SUSPENDED, CEILING MOUNTED
LED FIXTURE, STANCHION MOUNTED
LED FIXTURE, WALL MOUNTED
LED LIGHTED EXIT SIGN. ARROWS DENOTE DIRECTION OF EGRESS
ON EACH SIDE OF FIXTURE. NO ARROW DENOTES NO DIRECTION OF
EGRESS
POLE MOUNTED LED LUMINAIRE. SEE SCHEDULE OR NOTES FOR
TYPE. ORIENT FIXTURE FOR CUT-OFF TOWARDS AREA TO BE LIT.
ORIENT HOUSE SHIELD TOWARDS BUILDING. SEE DETAILS FOR POLE
BASE. PROVIDE POLE BASE GROUND ROD.
REMOTE EMERGENCY LIGHTS
EMERGENCY LED LIGHT FIXTURE, SELF CONTAINED, BATTERY
OPERATED
PAR LAMP HOLDER. NUMBER OF TRIANGLES INDICATE NUMBER OF
FIXTURES
POLE MOUNTED FLOOR LIGHT. NUMBER OF TRIANGLES INDICATE
NUMBER OF FIXTURES. ARROW DENOTES FOLDING POLE AND
DIRECTION POLE FOLDS DOWN.
LIGHTING FIXTURE LEGEND
ABBREVIATIONS
A AMPERES OR TRIP AMPERES
AC ALTERNATING CURRENT
A/C AIR CONDITIONING
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AIC SYMMETRICAL AMPERES
INTERRUPTING CAPACITY
AWG AMERICAN WIRE GUAGE
BLDG BUILDING
BKR BREAKER
C CONDUIT
CAP CAPACITOR
CKT CIRCUIT
CONT'D CONTINUED
CPT CONTROL POWER
TRANSFORMER
CT CURRENT TRANSFORMER
CU COPPER
DBL DOUBLE
DISC SW DISCONNECT SWITCH
DC DIRECT CURRENT
EMER EMERGENCY
EMT ELECTRICAL METALLIC
TUBING
ENCL ENCLOSURE
EP EXPLOSION PROOF
EQUIP EQUIPMENT
FM FLOW METER
FS FLOAT SWITCH
G GROUND WIRE
GALV GALVANIZED
GEN GENERATOR
GFI GROUND FAULT
INTERRUPTER CIRCUIT
GND GROUND
HDG HOT DIPPED GALVANIZED
HPG HIGH PRESSURE GAUGE
HPS HIGH PRESSURE SODIUM
HT HEIGHT
HZ HERTZ
INST INSTRUMENT
KV KILOVOLTS
KVA KILOVOLT AMPERES
KWH KILOWATT HOURS
LA LIGHTNING ARRESTOR
L-L LINE TO LINE
L-N LINE TO NEUTRAL
MCC MOTOR CONTROL CENTER
MFR MANUFACTURER
MIN MINIMUM
MTD MOUNTED
MTG MOUNTING
MRCT MULTI-RATIO CURRENT
TRANSFORMER
MV MERCURY VAPOR
N.C.NORMALLY CLOSED
NEC NATIONAL ELECTRICAL
CODE
NEMA NATIONAL ELECTRICAL
MANUFACTURER'S
ASSOCIATION
NEUT NEUTRAL
N.O.NORMALLY OPEN
NTS NOT TO SCALE
OC ON CENTER
OH OVERHEAD
P POLE
PC PHOTOCELL
PNL PANEL
PRI PRIMARY
PVC POLYVINYL CHLORIDE
REQ'D REQUIRED
RS RUN/STOP
RTD RESISTANCE TEMPERATURE
DETECTOR
SCH SCHEDULE
SEC SECONDARY
S/N SOLID NEUTRAL
SPACE SPACE(S) ONLY-NO
BREAKER OR DEVICE
SPARE SPARE BREAKER OR DEVICE
SPECS SPECIFICATIONS
S.D. BARE SOFT DRAWN BARE
SS HDWE STAINLESS STEEL
HARDWARE
SWBD SWITCHBOARD
SWGR SWITCHGEAR
TB TERMINAL BLOCK
TYP TYPICAL
UL UNERWRITERS
LABORATORIES
V VOLTS
VA VOLT AMPERES
W WATTS
W/WITH
W/O WITHOUT
WP WEATHERPROOF
XFMR TRANSFORMER
PHASE PHASE
1/C ONE CONDUCTOR
3/C THREE CONDUCTOR
1
CONNECTION TO EXISTING
IH
-
3
5
R
I
A
T
A
L
I
F
T
S
T
A
T
I
O
N
R
E
L
O
C
A
T
I
O
N
A
N
D
OF
F
S
I
T
E
S
E
W
E
R
I
M
P
R
O
V
E
M
E
N
T
S
Te
x
a
s
E
n
g
i
n
e
e
r
i
n
g
F
i
r
m
F
-
1
8
7
1
2
19
1
N
.
U
n
i
o
n
A
v
e
N
E
W
B
R
A
U
N
F
E
L
S
,
T
E
X
A
S
7
8
1
3
0
P
H
:
(
8
3
0
)
2
1
4
-
0
5
2
1
U
E
G
JANUARY 26, 2023
EL
E
C
T
R
I
C
A
L
A
B
B
R
E
V
I
A
T
I
O
N
S
,
LE
G
E
N
D
S
,
A
N
D
G
E
N
E
R
A
L
N
O
T
E
S
VICINITY MAP
PROJECT COORDINATES
PROJECT
LOCATION
SCHERTZ, TX 78132
29.622961, -98.243779
ELECTRICAL SITE PLAN - DEMOLITION
SCALE: N.T.S.
DEMOLITION NOTES:
1.FIELD VERIFY ALL UNDERGROUND UTILITIES, PIPING, CONDUITS,
AND OBSTRUCTIONS PRIOR TO EXCAVATING. REPAIR ANY
DAMAGE OF EXISTING OBSTRUCTION TO ORIGINAL CONDITION.
2.REMOVE ALL ABANDONED CONDUITS. CUT OFF BELOW TOP OF
SLAB. PLUG CONDUITS AND REPAIR SLAB TO ORIGINAL FINISH
UNLESS NOTED OTHERWISE ON PLANS.
3.REFER TO CIVIL AND/OR STRUCTURAL PLANS FOR ADDITIONAL
MODIFICATIONS.
4.LOCATE ALL UNDERGROUND CONDUITS, PIPING, AND OTHER
STRUCTURES BEFORE STARTING WORK.
5.COORDINATE WITH LOCAL UTILITY FOR REMOVAL OF ELECTRIC
SERVICE.
6.NO RECORD DRAWINGS OR SURVEY EXISTS FOR EXISTING
FACILITY. CONTRACTOR SHALL FIELD VERIFY EXISTING
CONDITIONS PRIOR TO BID AND DEMOLITION. SITE IS LOCATED
IN DIFFERENT LOCATION THAN PROPOSED SITE. ENTIRE SITE
SHALL BE DECOMMISSIONING PER TCEQ REQUIREMENTS.
EXISITNG LIFT STATION
(TO BE DEMOLISHED)
IH
-
3
5
R
I
A
T
A
L
I
F
T
S
T
A
T
I
O
N
R
E
L
O
C
A
T
I
O
N
A
N
D
OF
F
S
I
T
E
S
E
W
E
R
I
M
P
R
O
V
E
M
E
N
T
S
Te
x
a
s
E
n
g
i
n
e
e
r
i
n
g
F
i
r
m
F
-
1
8
7
1
2
19
1
N
.
U
n
i
o
n
A
v
e
N
E
W
B
R
A
U
N
F
E
L
S
,
T
E
X
A
S
7
8
1
3
0
P
H
:
(
8
3
0
)
2
1
4
-
0
5
2
1
U
E
G
JANUARY 26, 2023
EL
E
C
T
R
I
C
A
L
S
I
T
E
P
L
A
N
-
D
E
M
O
L
I
T
I
O
N
NOTES:
1.REFER TO CONDUIT SCHEDULE FOR FULL CONDUIT AND CABLE
REQUIREMENTS.
2.COORDINATE ELECTRICAL SERVICE WITH LOCAL POWER
COMPANY. ALL COORDINATION IS WITHIN SCOPE OF THIS
CONTRACT AT NO ADDITIONAL COST TO OWNER. PROVIDE
ADEQUATE SIZED TRANSFORMERS PER POWER COMPANY
STANDARDS.
3.CONDUITS SHALL NOT BE INSTALLED UNDERNEATH CONCRETE
STRUCTURES, MEANS OF EGRESS, OR WALKWAYS. ROUTE
AROUND EQUIPMENT AND AVOID CONFLICT WITH OTHER
UNDERGROUND EQUIPMENT.
4.EQUIPMENT SHALL NOT BE INSTALLED WITHIN ELECTRICAL
EASEMENTS. WHERE EASEMENT CONFLICT EXISTS, CONTACT
ENGINEER PRIOR TO INSTALLATION. CONTRACTOR IS
RESPONSIBLE FOR VERIFICATION OF ANY AND ALL EASEMENTS.
5.DO NOT INSTALL CONCRETE FOR EQUIPMENT OR DUCTBANK
OVER WATER OR SEWER LINES. FIELD VERIFY AND MARK ALL
UNDERGROUND LINES.
6.EQUIPMENT SHOWN MAY NOT TO BE SCALE. REFER TO ALL
PLAN SHEETS AND ELECTRICAL DETAILS FOR ADDITIONAL
INFORMATION. REFER TO CIVIL DRAWINGS FOR SITE
DIMENSIONS.
7.INSTALLATION SHALL BE PER LATEST VERSION OF NATIONAL
ELECTRICAL CODE, AND ALL APPLICABLE LOCAL
CODES/ORDINANCES. NOT ALL CODE AND STANDARD
REQUIREMENTS MAY BE SHOWN ON PLANS. CONTRACTOR
SHALL ADHERE TO CODES AND STANDARDS REGARDLESS OF
BEING SHOWN ON PLANS OR SPECIFICATIONS IN DETAILED
FASHION.
8.PROVIDE ADEQUATE WORKING SPACE FOR ALL ELECTRICAL
EQUIPMENT AND GENERATOR ENCLOSURE DOORS.
9.PROVIDE GROUND CONNECTION AT SERVICE, PANELS,
METALLIC EQUIPMENT AT RACK, PIPING, AND ALL METALLIC
PARTS WITHIN PROJECT SITE.
10.CONCRETE SPOILS SHALL NOT BE DUMPED ON SITE. DO NOT
OVER POUR DUCTBANKS. PROVIDE ADEQUATE FORMS PRIOR
TO POUR.
11.COORDINATE CONDUIT STUB-UP LOCATIONS WITH GENERATOR
MANUFACTURER PRIOR TO POURING HOUSEKEEPING PAD.
12.COORDINATE FINAL GENERATOR ENCLOSURE DIMENSIONS
PRIOR TO POURING HOUSEKEEPING PAD. CONTRACTOR SHALL
SIZE HOUSEKEEPING PAD 6 IN. LARGER ON ALL SIDES THAN
ENCLOSURE. REFER TO ELECTRICAL DETAILS FOR ADDITIONAL
REQUIREMENTS.
13.REFER TO SPECIFICATIONS AND ENTIRE DRAWING PACKAGE
PRIOR TO BID FOR FULL PROJECT REQUIREMENTS.
14.ALL EQUIPMENT SHOWN IS NEW UNLESS STATED OTHERWISE.
15.ALL ELECTRICAL EQUIPMENT CONCRETE FOUNDATIONS ARE TO
BE INSTALLED ABOVE FINISHED GRADE. ADDITIONAL ELEVATION
DUE TO FLOOD PLANE REQUIREMENTS ARE NOT SHOWN. REFER
TO CIVIL SHEETS FOR FLOOD PLAIN LEVEL AND MINIMUM
FOUNDATION HEIGHT REQUIREMENTS.
16.INSTALL TRANSFORMER POLE AND TERMINAL POLE AS
REQUIRED BY UTILITY STANDARDS AND COORDINATION.
ELECTRICAL SITE PLAN - PROPOSED
SCALE: 1 IN. = 10 FT.
1'
0 10'20'
SCALE: 1 IN. = 10 FT.
TO N. I-35 FRONTAGE ROAD
E
E
E E E E E
E
E
E
E
E
E
VICINITY MAP
PROJECT COORDINATES
PROJECT
LOCATION
SCHERTZ, TX 78132
29.622980, -98.243806
KEYED NOTES:
ELECTRICAL RACK.
PAD MOUNTED TRANSFORMER.
FLOATS/TRANSDUCER TERMINAL BOX.
LIFT PUMP TERMINAL BOX.
480/277V, 3Ø, 80KW DIESEL GENERATOR. RE:
SPECIFICATIONS.
BOLLARD (TYPICAL).
RADIO TOWER.
AREA LIGHT.
1
2
3
4
5
2
6
1
4
3
LTG010
RAD010
FLT010 LP010 LP011
LP020 LP021 XDCR010
LTG020 LTG030
GEN010 GEN011
GEN012 GEN013
SER010
5
7
8
7
8
8
8
6
RTU010
IH
-
3
5
R
I
A
T
A
L
I
F
T
S
T
A
T
I
O
N
R
E
L
O
C
A
T
I
O
N
A
N
D
OF
F
S
I
T
E
S
E
W
E
R
I
M
P
R
O
V
E
M
E
N
T
S
Te
x
a
s
E
n
g
i
n
e
e
r
i
n
g
F
i
r
m
F
-
1
8
7
1
2
19
1
N
.
U
n
i
o
n
A
v
e
N
E
W
B
R
A
U
N
F
E
L
S
,
T
E
X
A
S
7
8
1
3
0
P
H
:
(
8
3
0
)
2
1
4
-
0
5
2
1
U
E
G
JANUARY 26, 2023
EL
E
C
T
R
I
C
A
L
S
I
T
E
P
L
A
N
-
P
R
O
P
O
S
E
D
ELECTRICAL LOAD ANALYSIS
LOAD AMPS
PH A PH B PH C
LIFT PUMP NO 1 23 HP 28 28 28
LIFT PUMP NO 2 23 HP 28 28 28
MINI-POWER ZONE - L.S.15 KVA 18 18 18
25% OF LARGEST MOTOR 7 7 7
TOTAL LOAD 81 81 81
SERVICE AMPACITY
@ 277/480V, 3PH, 4W 100 100 100
SPARE AMPACITY 19 19 19
GENERATOR LOAD 81 81 81
GENERATOR AMPACITY 120 120 120
USE 22 KAIC RATED DEVICES AND BRACING
ELECTRICAL ONE-LINE DIAGRAM
NOTE: ITEMS IN GREYSCALE ARE EXISTING
NOTES:
1.CONTRACTOR SHALL VERIFY AVAILABLE FAULT CURRENT WITH
POWER COMPANY AND PROVIDE EQUIPMENT RATED
ACCORDINGLY. INTERRUPT CAPACITY FOR ALL COMPONENTS
SHALL BE SAME AS SERVICE.
2.PROVIDE ALL REQUIRED ALARM AND DEVICE POWER
CONDUCTORS FOR LOCAL PANELS INSTALLED NEAR MOTORS
AND EQUIPMENT. SEE ONE-LINE DIAGRAM, CONTROL DIAGRAMS
AND EQUIPMENT SPECIFICATIONS FOR REQUIREMENTS.
CONDUCTORS MAY BE ROUTED IN POWER CONDUITS WHERE
INSULATION RATING IS 600 VOLTS AND WHERE CONDUIT
AREA/SPACE IS PER NEC, OR SEPARATE 1 INCH CONDUIT SHALL
BE PROVIDED.
3.COORDINATE LVP BREAKER SIZES WITH GENERATOR
MANUFACTURER FOR AUXILIARY LOADS
4.VERIFY CAPACITOR SIZE REQUIREMENTS WITH MOTOR
MANUFACTURER BEFORE ORDERING. DO NOT OVERCORRECT.
PROVIDE CONDUCTORS AND CONDUITS SIZED ACCORDINGLY
TO NEC. CAPACITORS SHALL NOT BE DIRECTLY CONNECTED TO
RVAT AND SOLID STATE STARTERS. (USE CONTRACTOR, HOA,
TIME DELAY AND BREAKER) INTERLOCK WITH STARTERS.
5.ALL CONTROL PANELS TO BE UL LISTED.
6.CONTRACTORS SHALL READ ENTIRE CONTENTS OF
SPECIFICATIONS BEFORE BIDDING ON THIS PROJECT.
7.SEAL OFF FITTINGS ARE REQUIRED FOR ALL RACEWAYS
ENTERING AND EXITING WET WELL JUNCTIONS BOXES. FILL
SEAL OFF FITTINGS WITH 3M-2123 RE-ENTERABLE SEALING
COMPOUND.
8.ALL 480V LINE AND CONDUCTORS SHALL BE MEGGER TESTED
WITH A MINIMUM READING OF 50 OHMS TO BE ACCEPTABLE. ALL
TESTING SHALL BE WITNESSED BY AN ENGINEER.
9.REFER TO CONDUIT/CABLE SCHEDULE FOR ADDITIONAL
DETAILS.
10.NEUTRAL BONDING PER NATIONAL ELECTRICAL CODE ARTICLE
250.
11.SERVICE SHALL BE ADHERE TO LATEST UTILITY STANDARDS.
COORDINATE AND PAY FOR ALL UTILITY RELATED EXPENSES
PER POWER COMPANY ALLOWANCE.
12.COORDINATE ALL CONNECTIONS TO GENERATOR WITH
MANUFACTURER.
100A ATS
100A,3P
MCC-A 480V, 3Ø, 100A BUS,
APANEL
START
SOFT
LIFT
PUMP NO.1
22 KAIC, NEMA 3R NON WALKIN
#4/0 S.D. BARE COPPER
3/4ØX10 CU CLAD
GND ROD EXOTHERMIC
WELD TO GND CABLE
GROUND AS SHOWN ON
ELECTRICAL GROUNDING PLAN
LA
CAP
27 FLA
60A, 3P, 600V HEAVY DUTY NEMA 4X S.S.
DISCONNECT SWITCH
100:5
23
120/240V
23
15KVA 480V
40A,2PMCPMCP
ØF
G
BC
HTR
JWHT
GND1/0 B.C. GND
3/4 IN. x 10 FT.
Cu GROUND ROD
100A
80 KW (100 KVA), 120A
480V/277V, 3 PH, 4W
STANDBY DIESEL GENERATOR
TO PANEL
BOARD
GEN013
TO SCADA
TERMINAL BLOCK
GEN012
GEN010
M
POWER
COMPANY
TRANSFORMER
NEW 113 KVA PAD
MOUNT TRANSFORMER
480/277V, 3 PH, 4W
SE
R
0
1
0
LP
0
1
2
LP
0
2
2
LP
0
1
1
LP
0
2
1
LP
0
1
0
LP
0
2
0
FROM POWER
COMPANY
TVSS
SIEMENS
TSPE11 OR
APPROVED
EQUAL
PHASE FAIL
RELAY
START
SOFT
LIFT
PUMP NO.2
27 FLA
SIEMENS
9500 POWER
MONITOR OR
APPROVED
EQUAL
IH
-
3
5
R
I
A
T
A
L
I
F
T
S
T
A
T
I
O
N
R
E
L
O
C
A
T
I
O
N
A
N
D
OF
F
S
I
T
E
S
E
W
E
R
I
M
P
R
O
V
E
M
E
N
T
S
Te
x
a
s
E
n
g
i
n
e
e
r
i
n
g
F
i
r
m
F
-
1
8
7
1
2
19
1
N
.
U
n
i
o
n
A
v
e
N
E
W
B
R
A
U
N
F
E
L
S
,
T
E
X
A
S
7
8
1
3
0
P
H
:
(
8
3
0
)
2
1
4
-
0
5
2
1
U
E
G
JANUARY 26, 2023
EL
E
C
T
R
I
C
A
L
O
N
E
-
L
I
N
E
D
I
A
G
R
A
M
CR1
M1
M2
HOA
HOA
OT1
SF1
OT2
SF2
LT
LLC
LLC
LIFT PUMP NO.1 ON/OFF STATUS (M1)
1
TB1
2
3
6
5
4
8
9
11
10
7
13
14
17
16
15
19
18
22
21
20
24
23
27
26
25
30
29
31
32
28
35
34
38
37
36
40
39
33
12
LIFT PUMP NO.1 CONTROL SW IN AUTO POSITION (CS1)
41
42
45
44
48
47
46
50
49
43
51
52
55
54
58
57
56
60
59
53
LIFT PUMP NO.2 ON/OFF STATUS (M2)
LIFT PUMP NO.2 CONTROL SW IN AUTO POSITION (CS2)
SCADA TERMINATIONS TERMINAL BLOCK
LOSS OF CONTROL POWER (CR1)
COMMON PUMP FAIL (CR8)
LOW LEVEL (CR4/CR6)
HIGH LEVEL (CR5/CR7)
1
2
MCC CONTROL DIAGRAM DIAGRAM MCC CONTROL SECTION RTU TERMINAL BLOCK DIAGRAM
CONNECTIONS TO RTU BY
SCADA CONTRACTOR
(REFER TO SPECIFICATIONS
FOR APPROVED SCADA
INTEGRATOR)
LIFT PUMP
NO. 1
ON/OFF
LIFT PUMP
NO. 2
ON/OFF
LOSS OF
POWER
LIFT PUMP
NO. 1 IN
AUTO
LIFT PUMP
NO. 2 IN
AUTO
LIFT PUMP
NO. 1
OVERTEMP
LIFT PUMP
NO. 1
SEAL FAIL
LIFT PUMP
NO. 2
OVERTEMP
LIFT PUMP
NO. 2
SEAL FAIL
LIQUID
LEVEL
CONTROLLER
(LLC)
DIGITAL
INPUTS
ON/OFF LIFT
PUMP NO. 1
STARTER CKT
ON/OFF LIFT
PUMP NO. 2
STARTER CKT
RELAY
OUTPUTS
WET WELL LEVEL
TRANSMITTER SIGNAL
LOW
LEVEL
HIGH
LEVEL
COMMON
PUMP FAIL
TO
SCADA
RTU
INTRUSION ALARM
LIFT STATION GENERAL ALARM
ON/OFF LIFT PUMP NO. 1 STARTER CIRCUIT
ON/OFF LIFT PUMP NO. 2 STARTER CIRCUIT
WET WELL LEVEL (4-20 mA)
GENERATOR RUN
LOSS OF MAIN POWER (ØF)
IH
-
3
5
R
I
A
T
A
L
I
F
T
S
T
A
T
I
O
N
R
E
L
O
C
A
T
I
O
N
A
N
D
OF
F
S
I
T
E
S
E
W
E
R
I
M
P
R
O
V
E
M
E
N
T
S
Te
x
a
s
E
n
g
i
n
e
e
r
i
n
g
F
i
r
m
F
-
1
8
7
1
2
19
1
N
.
U
n
i
o
n
A
v
e
N
E
W
B
R
A
U
N
F
E
L
S
,
T
E
X
A
S
7
8
1
3
0
P
H
:
(
8
3
0
)
2
1
4
-
0
5
2
1
U
E
G
JANUARY 26, 2023
EL
E
C
T
R
I
C
A
L
C
O
N
T
R
O
L
A
N
D
SC
H
E
M
A
T
I
C
D
I
A
G
R
A
M
S
STARTSOFT OL
M1
OL
M1
OL
M1
100A,3P
GROUND BUS
M1
AUTOHANDOFF
HAND
AUTO PC
CKT A-2
FLOODLIGHT
YARD LIGHTING
STARTSOFT OL
M2
OL
M2
OL
M2
MCPMCP
CR13
CR12
CS-1
CS-2
M2
CR20
CR7
CR6
TWO PUMP
ALTERNATOR
(ALT)
RELAYSAFE
INTRINSICALLY
FLOAT SWHIGH LEVEL ALARM
RESET FLOAT SWHIGH LEVEL ALARM
CR1
FLOAT SWLAG PUMP ON
FLOAT SWLEAD PUMP ON
FLOAT SWPUMPS STOP
FLOAT SWLOW LEVEL LOCKOUT
CR5
CR2
CR3
CR4
CR5 CR12CR11
CR12
RESET FLOAT SWLOW LEVEL LOCKOUT
CR10
CR11
LOW LEVEL LOCKOUT OF PUMPS
CR1 CR13CR10
CR13
WET WELL HIGH LEVEL
RWET WELL LOW LEVEL LOCKOUT
RWET WELL HIGH LEVEL
CR12
CR13
CR2 CR6LAG PUMP ONCR4CR12
CR6
CR3 CR7LEAD PUMP ONCR4CR12
CR7
ØF PMCLOSE ON LOSS OF POWER
CONTROL POWER POWER ON
PUMP NO. 1
SEAL FAILURE
MOTOR
OVERTEMP
INTRINSICALLY
SAFE
RELAY
COORDINATE
RELAY WITH
PUMP VENDOR
CR18
CR19MOTOR SEAL
FAIL
@ PUMP
MOTOR
OVERTEMP
@ PUMP
MOTOR
OVERTEMP
@ PUMP
RESET
CR14
CR15
TD1
0-10 MIN.ELAPSED TIME METER
M1
M1
M1
PUMP NO.1 OFF
PUMP NO.1 ON
AUTO
AUTO
HAND
OFFHAND
T.O.E.
ETM
G
R
PUMP NO.1
M1
NOTE 2TD1
CO1 PM
CONTROL SW
CS-1
0-10 MIN.ELAPSED TIME METER
M2
M2
M2
PUMP NO.2 OFF
PUMP NO.2 ON
AUTO
AUTO
HAND
OFFHAND
T.O.E.
ETM
G
R
PUMP NO.2
M2
NOTE 2TD2
CO2 PM
CS-2
CR12
CR12
SCADA CONTROL PUMPS FROM SCADA RTU CRSCLOSED WHEN SCADA CONTROLS PUMPS
CRS
CRS
CRS
CRS
PUMP NO.1 MOTOR OVERLOADS CO1
APUMP NO.1 MOTOR OVERLOAD
PUMP NO.2 MOTOR OVERLOADS CO2
APUMP NO.2 MOTOR OVERLOAD
PUMP NO.1 OVER TEMPERATURE
PUMP NO.1 SEAL FAILURE
CR18
CR19
A
A
PUMP NO.2 OVER TEMPERATURE
PUMP NO.2 SEAL FAILURE
CR14
CR15
A
A
PUMP NO.3 OVER TEMPERATURE
PUMP NO.3 SEAL FAILURE
CR16
CR17
A
A
R
HORN ON
OUTSIDE OF
PANEL
TEST
ASR
ALARM SILENCE
CR20
ALARM LIGHT ON
OUTSIDE OF PANEL
ASR
ASR
CO1
CO2
CR14
CR15
CR18
CR19
120V
480V
LIFT PUMP
NO.1
23
LIFT PUMP
NO.2
23
PHASE FAILURE
RELAY (TYP) SQ D
TYPE DAS OR EQUAL
NEMA 1 MOTOR CONTROL
CENTER CABINET. ALL
SWITCHES, LIGHTS TO BE
MOUNTED ON INTERNAL
SWING PANEL
SURGE
ARRESTOR
LOCATED ON
OUTSIDE OF
PANEL
MOTOR OVERTEMP
SEAL FAIL
MOTOR SEAL
FAIL
@ PUMP
MOTOR
OVERTEMP
@ PUMP
MOTOR
OVERTEMP
@ PUMP
RESET PUMP NO. 2
SEAL FAILURE
MOTOR
OVERTEMP
INTRINSICALLY
SAFE
RELAY
COORDINATE
RELAY WITH
PUMP VENDOR
MOTOR OVERTEMP
SEAL FAIL
CONTROL SW
TD2
PUMP NO.2
RUN TO
SCADA RTU
PUMP NO.1
RUN TO
SCADA RTU
LOW LEVEL
ALARM TO SCADA
RTU (NOTE 14)
HIGH LEVEL ALARM
TO SCADA RTU
PUMP NO.1 CONTROL
SW IN AUTO POSITION
TO SCADA RTU
PUMP NO.2 CONTROL
SW IN AUTO POSITION
TO SCADA RTU
LIFT STATION
GENERAL ALARM
NOTES:
1.SET TIME DELAY SUCH THAT ONLY ONE PUMP
WILL BE IN START MODE AT ANY ONE TIME.
PHOTOCELL
@ POLE
F
480V, 3Ø
CKT A-1
GFI CONV. RECEPTACLE
NOTES:
1.PROVIDE SINGLE ALARM RESET SWITCH FOR ALL DEVICES
INCLUDING PUMP PROTECTION MODULES, OVERLOADS,
AND ALARMS. MOUNT TO INNER DOOR OF CONTROL
PANEL.
2.REFER TO ABBREVIATION PAGE FOR SYMBOL LEGEND.
3.CONTRACTOR TO INSTALL ALL SAFETY AND ACCESSORIES
REQUIRED BY PUMP VENDOR.
4.COORDINATE TIME DELAY RELAY SETTINGS SO THAT ONLY
ONE PUMP WILL BE IN START MODE AT ONE TIME - START
AT 30 SECOND INTERVALS.
5.ALL INDICATING LIGHTS TO BE LED PUSH TO TEST OIL
TIGHT TYPE.
6.ALL SWITCHES, INDICATING LIGHTS, AND PUSH BUTTONS
TO BE MOUNTED ON INNER SWING PANEL.
7.ALL CONTROLS FOR EQUIPMENT INSIDE WET WELL ARE TO
BE INTRINSICALLY SAFE.
8.PROVIDE SUBMITTAL WITH ALARM WIRING DIAGRAM FOR
ENGINEERS REVIEW.
9.MAINTAIN MINIMUM SEPARATION REQUIRED UNDER NEC
ARTICLE 504 BETWEEN INTRINSICALLY SAFE CONTROL
WIRING AND NON-INTRINSICALLY SAFE MOTOR FEEDER
WIRING.
10.COORDINATE WITH PUMP MANUFACTURER FOR PUMP
PROTECTION MODULE PROVIDE AND INSTALL MODULE
SEAL FAIL AND OVERTEMP.
11.WHERE ADDITIONAL CONTACTS ARE REQUIRED, PROVIDE
ADDITIONAL CONTACT BLOCK OR ADDITIONAL RELAYS
WITH COILS WIRED IN PARALLEL.
12.PROVIDE CIRCUIT FUSES RECOMMENDED BY
MANUFACTURER.
13.COORDINATE ALL NORMALLY CLOSED AND NORMALLY
OPEN CONTACTS.
14.CONTRACTOR SHALL COORDINATE NEW CONTROLS TO
PUMP CONTROLLER BASED ON EXISTING SIGNALS. NO
RECORD DRAWINGS EXIST FOR CURRENT LIFT STATION.
PROVIDE COST IN BID FOR DOCUMENTATION OF EXISTING
MONITORED SIGNALS AND PROVIDE SIMILAR SIGNALS TO
PUMP CONTROLLER FOR NEW PANEL. NOT ALL SIGNALS
TO RTU ARE SHOWN ON THIS SHEET.
15.CONTRACTOR IS RESPONSIBLE FOR TESTING AND
MODIFICATION OF PUMP CONTROLLER FOR NEW PUMPS
AND NEW CONTROLS. COORDINATE WITH CITY FOR VISUAL
AT OPERATING CENTER. ALL COORDINATION AND
MODIFICATION TO RTU CONNECTIONS ARE PART OF THIS
CONTRACT FOR A FULLY OPERATIONAL SCADA SYSTEM.
INTRUSION
ALARM
ALT 2
ALT 1
- DENOTES DEVICE IS REMOTE FROM PANEL.
CR12
CR13
CR20
PM
ELECTRICAL LIFT PUMPS CONTROL PANEL
IH
-
3
5
R
I
A
T
A
L
I
F
T
S
T
A
T
I
O
N
R
E
L
O
C
A
T
I
O
N
A
N
D
OF
F
S
I
T
E
S
E
W
E
R
I
M
P
R
O
V
E
M
E
N
T
S
Te
x
a
s
E
n
g
i
n
e
e
r
i
n
g
F
i
r
m
F
-
1
8
7
1
2
19
1
N
.
U
n
i
o
n
A
v
e
N
E
W
B
R
A
U
N
F
E
L
S
,
T
E
X
A
S
7
8
1
3
0
P
H
:
(
8
3
0
)
2
1
4
-
0
5
2
1
U
E
G
JANUARY 26, 2023
EL
E
C
T
R
I
C
A
L
S
C
H
E
M
A
T
I
C
DI
A
G
R
A
M
CABLE AND CONDUIT SCHEDULE
CABLE/CONDUIT TAG CONDUIT QUANTITY CONDUIT SIZE FROM TO CONDUCTOR (EACH CONDUIT)CABLE TYPE DESCRIPTION
FLT010 1 1 & 1/2 IN.CONTROL CABINET FLOATS TERMINAL BOX 14-#12 + #12 GND THWN-2 FLOATS
FLT011 1 1 & 1/2 IN.FLOATS TERMINAL BOX WET WELL (7) MANUFACTURER'S CABLE -FLOATS
GEN010 1 2 IN.ATS EMERGENCY GENERATOR 3-#1 + #6 GND XHHW-2 EMERGENCY POWER
GEN011 1 1 IN.EMERGENCY GENERATOR ATS 3-#12 + #12 GND THWN-2 ATS CONTROLS
GEN012 1 1 IN.EMERGENCY GENEERATOR CONTROL CABINET 4-#12 + #12 GND THWN-2 GENERATOR ALARM SIGNALS
GEN013 1 1 IN.PANELBOARD A EMERGENCY GENERATOR 12-#10 + #12 GND THWN-2 GENERATOR DEVICES (HEATER, BATTERY CHARGER, LIGHTS, JWH, LIGHTS, RECEP.)
LP010 1 1 1/2 IN.CONTROL CABINET LIFT PUMP NO. 1 TERMINAL BOX 3-#8 + #10 GND THWN-2 LIFT PUMP NO. 1 POWER
LP011 1 1 IN.CONTROL CABINET LIFT PUMP NO. 1 TERMINAL BOX 6-#12 + #12 GND THWN-2 LIFT PUMP NO. 1 ALARMS
LP012 1 1 1/2 IN.LIFT PUMP NO. 1 TERMINAL BOX LIFT PUMP NO. 1 MANUFACTURER'S CABLE -LIFT PUMP NO. 1 CABLE
LP020 1 1 1/2 IN.CONTROL CABINET LIFT PUMP NO. 2 TERMINAL BOX 3-#8 + #10 GND THWN-2 LIFT PUMP NO. 2 POWER
LP021 1 1 IN.CONTROL CABINET LIFT PUMP NO. 2 TERMINAL BOX 6-#12 + #12 GND THWN-2 LIFT PUMP NO. 2 ALARMS
LP022 1 1 1/2 IN.LIFT PUMP NO. 2 TERMINAL BOX LIFT PUMP NO. 2 MANUFACTURER'S CABLE -LIFT PUMP NO. 2 CABLE
LTG010 1 1 IN.PANELBOARD A AREA LIGHT 4-#12 + #12 GND THWN-2 AREA LIGHT AND RECEPTACLE
LTG020 1 1 IN.PANELBOARD A AREA LIGHT 4-#12 + #12 GND THWN-2 AREA LIGHT AND RECEPTACLE
LTG030 1 1 IN.PANELBOARD A AREA LIGHT 4-#12 + #12 GND THWN-2 AREA LIGHT AND RECEPTACLE
RAD010 1 1 1/2 IN.CONTROL CABINET ANTENNA TOWER (1) COAX CABLE -RADIO COAX CABLE
REC010 1 1 IN.PANELBOARD A CONVENIENCE RECEPTACLE 2 - #12 + #12 GND THWN-2 WET WELL CONVENIENCE RECEPTACLE
RTU010 1 2 IN.MCC CONTROL SECTION RTU PANEL 32 - #14 + GND + 4-20 mA TWISTED PAIR -RTU SIGNALS (BY CITY SCADA CONTRACTOR)
SER010 1 2 IN.UTILITY TRANSFORMER MOTOR CONTROL CENTER 4 - #1 + #6 GND XHHW-2 UTILITY SERVICE
XDCR010 1 1 IN.CONTROL CABINET TRANSDUCER TERMINAL BOX TWISTED PAIR CABLE -PRESSURE TRANSDUCER
XDCR011 1 1 IN.TRANSDUCER TERMINAL BOX STILLING WELL MANUFACTURER'S CABLE -PRESSURE TRANSDUCER
NOTES:
1.PROVIDE INTERMEDIATE JUNCTION BOX SHOULD PRESSURE
TRANSDUCER CABLE NOT BE SUFFICIENT FROM BOTTOM OF
WET WELL TO SCADA PANEL CONTROLLER.
2.PROVIDE 12 IN. CLEARANCE BETWEEN POWER CONDUITS AND
COMMUNICATION CONDUITS WITHIN DUCTBANKS.
VOLTAGE DROP
FROM TO LENGTH CONDUCTORS
PER PHASE WIRE SIZE Cm LOAD VOLTAGE VOLTAGE
DROP%
UTILITY TRANSFORMERS 1 FT.1 #1 83690 81 480 0.00%
TRANSFORMERS CONTROL PANEL 60 FT.1 #1 83690 81 480 0.27%
CONTROL PANEL LIFT PUMPS 15 FT.1 #8 16510 41 480 0.17%
FAULT CURRENT CALCULATIONS
FROM TO AVAILABLE FAULT
@ SOURCE
CONDUCTORS
PER PHASE
WIRE
SIZE C VOLTAGE LENGTH
(FT.)F M FAULT CURRENT
@ LOAD
MINIMUM
KAIC RATING
UTILITY TRANSFORMERS 15668.99 1 #1 7493 480 1 0.01 0.99 16118.64 22
TRANSFORMERS MCC 16118.64 1 #1 7493 480 60 0.47 0.68 11563.93 22
MCC LIFT PUMPS 11563.93 1 #8 1559 480 15 0.40 0.71 8818.19 22
NOTES:
1. A PERMANENTLY AFFIXED LABEL SHALL BE APPLIED WITH THE FAULT CURRENT AT THE TIME OF INSTALLATION AND FAULT STUDY. THE LABEL SHALL INCLUDE THE
DATE OF THE CALCULATION. REFER TO SPECIFICATIONS.
2. ALL SERVICES SHALL BE IDENTIFIED WITH A PERMANENT LABEL AT EACH DISCONNECT PER NEC 230.2.
3. VERIFY NAMEPLATE AND MANUFACTURER'S REQUIREMENTS ON ALL MOTORS PRIOR TO ORDERING EQUIPMENT.
CKT. DESCRIPTION WIRE BREAKER VA/WATTS CKT
NO.
CKT
NO.
VA/WATTS BREAKER WIRE CKT. DESCRIPTIONPOLEAMPABCABCPOLEAMP
JACKET WATER HEATER NO. 1 8 2 30 1500 1 2 180 1 20 12 CONVENIENCE RECEPTACLE
1500 3 4 800 1 20 12 GENERATOR BATTERY CHARGER
CONTROLS 12 1 20 300 5 6 180 1 20 12 CONVENIENCE RECEPTACLE
JACKET WATER HEATER NO. 2 8 2 30 1500 7 8 180 1 20 12 YARD LIGHT NO. 1
1500 9 10 180 1 20 12 YARD LIGHT NO. 2
CONTROLS 12 1 20 300 11 12 180 1 20 12 YARD LIGHT NO. 3
GENERATOR LIGHTS 12 1 20 180 13 14 -1 20 SPARE
GENERATOR RECEPTACLE 12 1 20 180 15 16 -1 20 SPARE
SHELTER LIGHTS 12 1 20 220 17 18 -1 20 SPARE
MCC LIGHTS 12 1 20 180 19 20 -1 20 SPARE
SPARE 1 20 -21 22 -1 20 SPARE
SPARE 1 20 -23 24 -1 20 SPARE
TOTAL PHASE A: 3720 VOLT-AMPS
TOTAL PHASE B: 4160 VOLT-AMPS
TOTAL PHASE C: 1180 VOLT-AMPS
TOTAL PHASE A CURRENT: 31 AMPS
TOTAL PHASE B CURRENT: 35 AMPS
TOTAL PHASE C CURRENT: 10 AMPS
TOTAL CONNECTED LOAD: 8300 VA
WITH:PANEL
NEUTRAL BUS RATING
SOLID NEUTRAL & GROUND
ISOLATED GROUND BUS
200% NEUTRAL
NOTE: ADJ. CKTS. TO BAL. PNL.MAIN BREAKER SIZE MOUNTING
PHASE
WIRE SIZE
NEU WIRE SIZE
LOCATION
SHORT CIRCUIT RATING
PHASE BUS RATING
SERVICE VOLTAGE
A
120/208V
40A
100A
100A
22 KAIC
MCC
#10
#10
3
MCC
LUMINAIRE FIXTURE SCHEDULE
SYMBOL DESCRIPTION VOLTAGE LUMENS WATTAGE MOUNTING MANUFACTURER LUMINAIRE CATALOG NUMBER POLE DATA
AL VAPORTITE ALARM/LIGHT 120V 4,000 -AS NOTED LITHONIA OR EQUAL OLVTWM -
B WALL PACK 120V 5,174 -WALL LITHONIA TWP LED AL0 50K HARDWARE, ANCHORS, AND HINGE PIN SHALL BE 316 SS
SEAL PENETRATIONS WITH LIQUID TIGHT GROUT
F AREA LIGHT 120V 27,900 231 POLE LITHONIA DSX1 LED-P5-50K-T5W-MVOLT-DDBXD -
IH
-
3
5
R
I
A
T
A
L
I
F
T
S
T
A
T
I
O
N
R
E
L
O
C
A
T
I
O
N
A
N
D
OF
F
S
I
T
E
S
E
W
E
R
I
M
P
R
O
V
E
M
E
N
T
S
Te
x
a
s
E
n
g
i
n
e
e
r
i
n
g
F
i
r
m
F
-
1
8
7
1
2
19
1
N
.
U
n
i
o
n
A
v
e
N
E
W
B
R
A
U
N
F
E
L
S
,
T
E
X
A
S
7
8
1
3
0
P
H
:
(
8
3
0
)
2
1
4
-
0
5
2
1
U
E
G
JANUARY 26, 2023
EL
E
C
T
R
I
C
A
L
S
C
H
E
D
U
L
E
S
GENERATOR & TANK DATA
ITEMS DATA
GENERATOR*
80 KW (MIN.), 100 KVA, 120A
W/ 300 GAL. SUB BASE DIESEL FUEL TANK (UL 142).
FUEL CONSUMPTION RATE FULL LOAD - 6.3 GPH
WT = 2,750 LBS. (GENERATOR AND ENCLOSURE)
ENCLOSURE*SOUND ATTENUATING: 72dB @ 23 FT. (MIN.) (LEVEL 2)
DIM. 120 IN. L x 46 IN. W x 64 IN. H
NFPA 110 CLASS 24, TYPE 10, LEVEL 2
* VERIFY EQUIPMENT PARAMETERS WITH THE SPECIFIC
MANUFACTURER
GENERAL NOTES:
1.CONDUCTING GENERATOR TESTS, SET MOTOR STARTER TIME
DELAY RELAYS IN THE ORDER OF MOTOR SIZE SMALLEST TO
LARGEST, WITH FIRST SETTING AT 10 SECONDS AND EACH
CONSECUTIVE TIME DELAY AT 10 SECOND GREATER
INCREMENTS. I.E. P1 TD = 10 SEC; P2 TD = 20 SEC, P3 TD = 30 SEC.,
ETC. THESE SETTINGS SHOULD NEVER BE CHANGED TO ASSURE
PROPER LOAD SEQUENCING ON GENERATOR. RECORD
SETTINGS AND INCLUDE IN RECORD-BUILT.
2.PROVIDE DIGITAL CONTROLLER, OR APPROVED EQUAL, WITH
RJ-45 COMMUNICATION TO ETHERNET SWITCH.
SOUND ATTENUATED GENERATOR ENCLOSURE DETAIL
SCALE: N.T.S.
HIGH
VOLTAGE
KEEP OUT
HIGH
VOLTAGE
KEEP OUT
NOTE:
1.COORDINATE CONDUIT LOCATIONS WITH GENERATOR MANUFACTURER.
2.DO NOT ROUTE GROUND CONDUCTORS ACROSS TOP OF SLAB INSIDE OR OUTSIDE
ENCLOSURE. INSTALL IN SCHEDULE 80 PVC SLEEVE IN SLAB.
3.PROVIDE UL RATED CLASS B FIRE EXTINGUISHER, PROPLUS MODEL PROPLUS5MP FOR FUEL
TYPE, PER GENERATOR MANUFACTUER'S RECOMMENDATIONS AND FIELD LOCATE.
PVC
36 IN. (TYPICAL)2 IN. (TYPICAL)
GRADE
2/0 BARE COPPER
TO GROUND GRID
AND WELL (NOTE 3)
GROUND LUG
THERMO-WELDED
CONNECTION
WEATHERPROOF SOUND
ATTENUATED ENCLOSURE
WEATHERPROOF EMERGENCY
STOP BUTTON ON BOTH SIDES
2 1
TO TRANSFER
SWITCH
RGS ELBOW
3
KEYED NOTES:
HEARING SIGN (TYPICAL). RE: HEARING SIGN DETAIL SHEET 9.
HIGH VOLTAGE SIGN (TYPICAL). RE: HIGH VOLTAGE SIGN DETAIL
SHEET 9.
GENERATOR CONCRETE HOUSEKEEPING PAD. RE: GENERATOR
HOUSEKEEPING PAD DETAIL SHEET 8.
1
3/8 IN. DIAMETER HARDENED
SS ANCHOR BOLTS
(TYPICAL BOTH SIDES)
RGS ABOVE GRADE
3 IN. RED CONCRETE
ENCASEMENT
2
3
FIRE EXTINGUISHER
(NOTE 5)
GENERATOR CONCRETE HOUSEKEEPING PAD DETAIL
SCALE: N.T.S.
COMPACTED
BASE MATERIAL CONCRETE FOUNDATION 12 IN. x 24 IN. CONCRETE BEAM
WITH 2-#7 TOP, 2-#8 BOTTOM
AND #3 STIRRUPS AT 18 IN. O.C.
MINIMUM SIZE - SAME AS UNIT PLUS 6 IN. ON ALL SIDES
TOP OF CONCRETE PAD (TO BE LEVEL)
6 IN. CONCRETE SLAB WITH #4 AT 8 IN.
O.C. BOTH WAYS IN TOP OF SLAB
CENTER BEAMS AT EQUAL INTERVALS IF DISTANCE BETWEEN BEAMS
EXCEEDS 15 FT. - 0 IN. PROVIDE ADDITIONAL INTERIOR BEAMS SO AS
TO KEEP BEAM SPACING AT A MAXIMUM OF 15 FT. - 0 IN. O.C.
L-UNIT LENGTH + 6 IN. EACH SIDE (MIN.)
W-
U
N
I
T
W
I
D
T
H
+
6
I
N
.
E
A
C
H
S
I
D
E
(
M
I
N
.
)
4 IN.
IH
-
3
5
R
I
A
T
A
L
I
F
T
S
T
A
T
I
O
N
R
E
L
O
C
A
T
I
O
N
A
N
D
OF
F
S
I
T
E
S
E
W
E
R
I
M
P
R
O
V
E
M
E
N
T
S
Te
x
a
s
E
n
g
i
n
e
e
r
i
n
g
F
i
r
m
F
-
1
8
7
1
2
19
1
N
.
U
n
i
o
n
A
v
e
N
E
W
B
R
A
U
N
F
E
L
S
,
T
E
X
A
S
7
8
1
3
0
P
H
:
(
8
3
0
)
2
1
4
-
0
5
2
1
U
E
G
JANUARY 26, 2023
GE
N
E
R
A
T
O
R
D
E
T
A
I
L
S
SH
E
E
T
1
HIGH
VOLTAGE
KEEP OUT
10 IN. (MINIMUM)
8
I
N
.
(
M
I
N
I
M
U
M
)
2 IN.
(MIN.)
1 IN.
(MIN.)
PAINTED ALUMINUM
HIGH VOLTAGE SIGN DETAIL
SCALE: N.T.S.
SS SCREWS (TYPICAL)
DUAL SOURCE SIGN DETAIL
SCALE: N.T.S.
STANDBY ____ GENERATOR LOCATED
ON ____ SIDE OF LIFT STATION.
AUTOMATIC TRANSFER SWITCH
LOCATED ON ____ SIDE OF LIFT STATION
CAUTION
TWO SOURCES OF SUPPLY
___/___V 3 PHASE
10 IN. (MINIMUM)
8
I
N
.
(
M
I
N
I
M
U
M
)
7/8 IN.
(MIN.)
3/8 IN.
(MIN.)
PAINTED ALUMINUM
SS SCREWS (TYPICAL)
WARNING
HEARING
PROTECTION
REQUIRED
WHEN
GENERATOR
RUNNING
12 IN. (MINIMUM)
1 & 1/2 IN.
(MIN.)
RED ON WHITE METALLIC SIGN
14
&
3
/
4
I
N
.
(
M
I
N
I
M
U
M
)
1 IN.
(MIN.)
HEARING WARNING SIGN DETAIL
SCALE: N.T.S.
SS SCREWS (TYPICAL)
FAULT CURRENT WARNING SIGN DETAIL
SCALE: N.T.S.
3/16 IN.
3 IN.
BLUE LETTERING ON
WHITE BACKGROUND
SS SCREWS
(TYPICAL)
AVAILABLE FAULT
CURRENT XXX KAIC
INSTALLATION DATE
XX/XX/XXXX
WARNING
2
I
N
.
1/4 IN.
NOTE:
1.CONTRACTOR TO FILL AVAILABLE FAULT CURRENT KAIC
BASED ON DATA OUTLET STATEMENT FROM ELECTRICAL
PROVIDER.
NOTE 1
B BGTW
B
3
B B
BB
GENERATOR PAD
NOTES:
1.THE GROUNDING SYSTEM SHALL BE TESTED BY AN
APPROVED TESTING FIRM TO ENSURE THE RESISTANCE
TO GROUND IS NO GREATER THAN 5 OHMS. CONTRACTOR
TO SUBMIT GROUND TESTING REPORT TO OWNER'S
REPRESENTATIVE.
1
1
1
1
2
2
4
TYPICAL GENERATOR
ELECTRICAL GROUNDING DETAIL
SCALE: N.T.S.
KEYED NOTES:
3/4 IN. x 10 FT. COPPER CLAD GROUNDROD.
EXOTHERMICALLY WELD TO GROUND CABLE BURIED 18 IN.
(MINIMUM) BELOW GRADE.
4/0 SOFT DRAWN BARE COPPER CABLE BURIED 18 IN.
(MINIMUM) BELOW GRADE (TYPICAL ALL BELOW GRADE
CABLE). EXOTHERMICALLY WELD ALL BELOW GRADE
CONNECTIONS
EXTEND #6 SOFT DRAWN BARE COPPER UP INTO
EQUIPMENT.
REFER TO GROUNDING TEST WELL INSTALLATION DETAIL.
EXTEND #4/0 TO EXIST GROUND MAT AT ELECTRICAL
EQUIPMENT CANOPY AND EXOTHERMICALLY WELL TO
EXISTING GROUNDING SYSTEM.
1
2
3
4
5
B
5
IH
-
3
5
R
I
A
T
A
L
I
F
T
S
T
A
T
I
O
N
R
E
L
O
C
A
T
I
O
N
A
N
D
OF
F
S
I
T
E
S
E
W
E
R
I
M
P
R
O
V
E
M
E
N
T
S
Te
x
a
s
E
n
g
i
n
e
e
r
i
n
g
F
i
r
m
F
-
1
8
7
1
2
19
1
N
.
U
n
i
o
n
A
v
e
N
E
W
B
R
A
U
N
F
E
L
S
,
T
E
X
A
S
7
8
1
3
0
P
H
:
(
8
3
0
)
2
1
4
-
0
5
2
1
U
E
G
JANUARY 26, 2023
GE
N
E
R
A
T
O
R
D
E
T
A
I
L
S
SH
E
E
T
2
MCC-A
EXTEND UP INTO MCC-A AND GROUND TO GROUND BUS
3/4"ØX10' COPPER CLAD GROUNDROD. EXOTHERMICALLY WELD TO
#4/0 SOFT DRAWN BARE COPPER CABLE BURIED MIN 18" BELOW
GRADE (TYP ALL BELOW GRADE CABLE). EXOTHERMICALLY WELD ALL
BELOW GRADE CONNECTIONS
GROUND CABLE BURIED MIN 18" BELOW GRADE
3
4
1
KEYED NOTES:
2
GTW
REFER TO GROUNDING SYSTEM TEST WELL
1
1 1
12
2
22
2
3 433
2
NOTE: COORDINATE EXACT SIZE OF FOUNDATION WITH ALL TRADES.
SPACE
MOTOR CONTROL CENTER FRONT ELEVATION DETAIL
SCALE: N.T.S.
PROPOSED TYPICAL ELECTRICAL GROUNDING DETAIL
SCALE: N.T.S.
1 IN. CHAMFER ALL
EXPOSED EDGES
20 IN.30 IN.20 IN.20 IN.20 IN.20 IN.30 IN.
MAIN BREAKER
TRANSFER
SWITCH TVSS
POWER
MONITOR
PHASE
FAILURE
SPACE
LIFT PUMP
NO. 1
LIFT PUMP
NO. 2 SPACE CONTROLS
SECTION
PANEL A
TRANSFORMER
BREAKER
TRANSFORMER
15 KVA / 3 PHSPACESPACE
FINISHED FLOOR
3 & 1/2 IN. HIGH CONCRETE
HOUSE KEEPING PAD
IH
-
3
5
R
I
A
T
A
L
I
F
T
S
T
A
T
I
O
N
R
E
L
O
C
A
T
I
O
N
A
N
D
OF
F
S
I
T
E
S
E
W
E
R
I
M
P
R
O
V
E
M
E
N
T
S
Te
x
a
s
E
n
g
i
n
e
e
r
i
n
g
F
i
r
m
F
-
1
8
7
1
2
19
1
N
.
U
n
i
o
n
A
v
e
N
E
W
B
R
A
U
N
F
E
L
S
,
T
E
X
A
S
7
8
1
3
0
P
H
:
(
8
3
0
)
2
1
4
-
0
5
2
1
U
E
G
JANUARY 26, 2023
EL
E
C
T
R
I
C
A
L
D
E
T
A
I
L
S
SH
E
E
T
1
DETAIL #3
SLIDE DOWN
OVER TAPPERED
END
TYPICAL ANTENNA TOWER DETAIL
SCALE: N.T.S.
YAGI ANTENNA
(REF.)
GALVANIZED
PIPE CAP
COAX CABLE
RTC400
10 FT. x 1 & 1/4 IN.
GALVAIZED POLE
BAND-IT SS
TIE WRAPS
DETAIL #1
GROUND LEVEL
TO CONTROL
PANEL
4 FT. x 4 FT. x 4 FT.
CONCRETE BASE
10 FT. x 5/8 IN.
Cu GROUND
ROD
30
F
T
.
-
0
I
N
.
3
F
T
.
-
0
I
N
.
6 IN.
4
F
T
.
-
0
I
N
.
6 IN.
10 FT. x 1 & 1/4 IN.
POLE (REF.)
DETAIL #1A
TOWER NECK
1/4 N. x 3 IN. BOLT
WITH 1/4 IN. NUT AND
(2) FLAT WASHERS
DETAIL #1B
BOTTOM OF
TOWER NECK
BOTTOM OF
10 FT. POLE
2
F
T
.
-
0
I
N
.
DETAIL #1
ANTENNA MOUNTING POLE
DETAIL #1A
NECK SUPPORT BOLT
10 FT. POLE
(REF.)
1/4 IN. x 3 IN. SS BOLT
W/ 1/4 IN. SS NUT AND
SS FLAT WASHER
THROUGH 10 FT. POLE
(ASSEMBLED BY DFS)
TOP OF TOWER
NECK (REF.)
1/4 IN. SS NUT W/
FLAT WASHER
DETAIL #1B
POLE SWIVEL BOLT SIDE VIEW
10 FT. POLE
(REF.)
BOTTOM OF TOWER
NECK (REF.)
NUT SLEEVE
3/8 IN. SS BOLT
3/8 IN. SS BOLT
SECURE W/ 1/4 IN.
SS NUT & BOLT
(3 PLCS)
SECURE W/ 5/16 IN.
SS NUT & BOLT
(3 PLCS)
TAPPERED END UP
(TYPICAL)
DETAIL #2
TOWER CONNECTING
DETAIL #3
COAX MOUNTING & ROUTING
1
F
T
.
-
6
I
N
.
(T
Y
P
I
C
A
L
)
57
.
0
6
ANTENNA
(REF.)
HEATSHRINK COAX
CONNECTION HERE
BAND-IT SS TIE WRAP
29.02
COAX CABLE SERVICE
LOOP (REFER TO RTU
MOUNT DETAIL FOR
CONTINUED ROUTING)
10 FT. POLE
(REF.)
BAND-IT SS TIE WRAP
TOWER LEG
ROUTE COAX CABLE
DOWN THIS TOWER LEG
TO THE BOTTOM OF RTU
3/8 IN. x 3/4 IN.
SS BOLT
TOWER LEG
3/8 IN. x 3/4 IN.
SS BOLT
TOWER LEG RTU FOOT
RTU FOOT
BACK OF RTU
RTU MOUNTING
DETAIL TOP VIEW
CONDUIT DETAIL
TOP VIEW
CONCRETE
FOUNDATION (REF.)
TOWER
(REF.)
1 & 1/2 IN.
1 FT. PVC CONDUIT MOUNTED
DIRECTLY IN FRONT OF LEFT
RTU MOUNT TOWER LEG
GENERAL NOTES:
1.TOWER AND FOUNDATION SUBMITTALS SHALL BE PROVIDED BY
PROFESSIONAL STRUCTURAL ENGINEER WITH AN ACTIVE
LICENSE IN THE STATE OF TEXAS.
2.TOWER SHALL BE RATED FOR WIND CATEGORY FOR LIFT
STATION PROJECT LOCATION.
3.RTU BOX SHALL BE DESIGNED, PROVIDED, INSTALLED, AND
PROGRAMMED BY CITY SCADA CONSULTANT. REFER TO
TECHNICAL SPECIFICATIONS FOR PRICING AND PAYMENT
PROCEDURES.
RTU BOX
(NOTE 3)
IH
-
3
5
R
I
A
T
A
L
I
F
T
S
T
A
T
I
O
N
R
E
L
O
C
A
T
I
O
N
A
N
D
OF
F
S
I
T
E
S
E
W
E
R
I
M
P
R
O
V
E
M
E
N
T
S
Te
x
a
s
E
n
g
i
n
e
e
r
i
n
g
F
i
r
m
F
-
1
8
7
1
2
19
1
N
.
U
n
i
o
n
A
v
e
N
E
W
B
R
A
U
N
F
E
L
S
,
T
E
X
A
S
7
8
1
3
0
P
H
:
(
8
3
0
)
2
1
4
-
0
5
2
1
U
E
G
JANUARY 26, 2023
EL
E
C
T
R
I
C
A
L
D
E
T
A
I
L
S
SH
E
E
T
2
FINISHED
GRADE
S.D. BARE
COPPER CABLE
TO GROUND LOOP
12
I
N
.
12
I
N
.
6
I
N
.
S.D. BARE
COPPER CABLE
TO GROUND LOOP
3/4 IN. DIA. x 10 FT. COPPER
CLAD GROUND ROD
PEA GRAVEL
12 IN. EXTENSTION
EXOTHERMIC WELDED
CONNECTION
CADWELD TYPE "GR"
"OLD CASTLE BROOKS"
PRODUCT NO. 3 CAST IRON
TRAFFIC COVER MARKED
"GROUND ELECTRODE"
6
I
N
.
1 IN.
GROUNDING SYSTEM TEST WELL DETAIL
SCALE: N.T.S. (TYPICAL)
SS TIEWRAP
REPLACE "LABEL"
WITH CONDUIT TAG
OR PANEL AND
CIRCUIT NUMBER
SS OR
ALUMINUM
STAMPED TAG
LABEL
NOTE:
1.AS-BUILT DRAWINGS SHOULD CONTAIN RECORD
OF ACTUAL INSTALLED CONDUITS AND
CONDUCTORS THAT COORDINATE WITH FIELD
LABELS. REFER TO SPECIFICATIONS FOR
ADDITIONAL REQUIREMENTS.
CONDUIT
CONDUIT LABEL DETAIL
SCALE: N.T.S. (TYPICAL)
SP
A
C
E
PE
R
N
E
C
PER NECSPACE
MARKER TAPE
12
I
N
.
GRADE
24
I
N
.
-
6
0
0
V
MARKER TAPE TO
READ "ELECTRICAL"
DUCTBANK WITH RED
CONCRETE ENCASEMENT
SMOOTH FINISH AND NO
CONCRETE OVERFLOW SPOILS
CONDUIT DEPTH PER NEC
(TYPICAL ALL DUCTBANKS)
3 IN.
(MIN.)
3
I
N
.
(M
I
N
.
)
#4 REBAR
STIRRUP
#4 REBAR
(TYPICAL)CONDUIT SPACER
(TYPICAL)
CONDUIT (TYPICAL)
(QUANTITY VARIES)
2/0 BARE Cu
30
I
N
.
-
1
5
K
V
DUCTBANK CONSTRUCTION DETAIL
SCALE: N.T.S.
NOTE:
1.GROUND ROD SHALL BE 3/4 IN. x 10 FT. FOR SURGE
PROTECTION GROUND AND LIGHTNING PROTECTION
SYSTEMS. ALL OTHER APPLICATIONS SHALL BE 3/4 IN. x 10 FT.
REMOVABLE COVER OF CAST
CONCRETE. TOP OF COVER
TO BE FLUSH WITH TOP OF
NATURAL GROUND, CONCRETE
OR ASPHALT SURFACE.
FLUSH LIFTING RING
"U" BOLTEXOTHERMIC
WELDED
CONNECTION
COPPERWELD
GROUND ROD (NOTE 1)
10 IN. VITRIFIED CLAY
PIPE OR REINFORCED
CONCRETE PIPE
2/0 BARE Cu UNLESS SHOWN
OTHERWISE ON PLAN OR
SPECIFICALLY DESCRIBED
IN SPECIFICATIONS
GROUND WELL DETAIL
SCALE: N.T.S.
GENERAL NOTES:
1.PROVIDE MANUALLY CONTROLLED FULL CUTOFF LED SITE
LIGHTING IN EACH PROCESS AREA: 15,000 LUMENS AND 4,000K.
PROVIDE SWITCHES, PHOTOCELLS, AND RECEPTACLES AT ALL
LIGHTING POLES.
2.ALL LIGHTING IS REQUIRED TO BE LED.
3.ALL ENCLOSURES, HARDWARE, STRAPS, AND ANCHORS TO BE
316 STAINLESS STEEL.
4.REFERENCE SHEET 21 FOR ADDITIONAL ELECTRICAL SHELTER
REQUIREMENTS.
5.DO NOT PENETRATE THE TOP OR UPPER 2/3 OF ENCLOSURES.
6.PROVIDE A 6 IN. MINIMUM CLEARANCE BETWEEN ENCLOSURES
7.MAINTAIN 12 IN. MINIMUM CLEARANCE FROM THE EDGE OF THE
OUTSIDE ENCLOSURE TO THE CENTER OF THE END POST.
NOTES:
1.REFER TO ROOF AND WALL DETAIL ON SHEET 12.
2.CONCRETE SHAFT PER NBU STANDARDS.
12 IN.
(MIN.)
FINISHED GRADE
12 IN.12 IN.
LENGTH AS REQUIRED TO ACHIEVE SPCIFIED CLEARANCE
20A RECEPTACLE
WITH IN-USE COVER
WEATHERPROOF
LIGHT SWITCH
C3x4.1 HD GALVANIZED
FRAME RAIL FULL LENGTH
BOTH SIDES WITH 1/2 IN.
THRU BOLTS (TYPICAL)
HSS 4 IN. x 4 IN. x 1/4 IN.
MINIMUM GALVAIZED
POST (TYPICAL)
6 IN. CONCRETE SLAB
W/#4 AT 16 IN. OUTSIDE
CIRCUMFERENCE
EACH WAY
3/4 IN. CHAMFER ALL
EXPOSED VERTICAL
AND HORIZONTAL
CORNERS (TYPICAL)
5
F
T
.
-
0
I
N
.
26 GA GALVANIZED R-PANEL
AND LAP SCREWS. ATTACH
TO EACH CROSS MEMBER
WITH FULL LENGTH HDG
HAT CHANNEL AND SELF
TAPPING SCREWS.
LIGHT FIXTURE TYPE "F"
(TYPICAL)
ROOF AND
WALL (NOTE 1)
CONCRETE SHAFT
(NOTE 2)
C3x4.1 HD GALVANIZED FRAME RAIL FULL
LENGTH WITH 1/2 IN. THRU BOLTS (TYPICAL)
FINISHED GRADE
6 FT. - 0 IN. (MIN.)
6 IN.
12 IN.
6 IN.
12
I
N
.
5
F
T
.
-
0
I
N
.
PERMETER BEAM
(TYP. ALL 4 SIDES)
12
3
8
F
T
.
-
0
I
N
.
(
M
I
N
.
)
LIGHT FIXTURE TYPE "F"
(TYP. OF 2)
C3x4.1 HD GALVANIZED
FRAME RAIL FULL LENGTH
BOTH SIDES WITH 1/2 IN.
THRU BOLTS (TYPICAL)
HSS 4 IN. x 4 IN. x 1/4 IN. (MIN.)
GALVANIZED POSTS (TYPICAL)
26 GA GALVANIZED
R-PANEL WALL (NOTE 1)
NOTE 2
26 GA GALVANIZED
R-PANEL ROOF (NOTE 2)
NOTES:
1.REFER TO ROOF AND WALL DETAIL ON SHEET 12.
2.SLOPE OF ON CONCRETE SLAB TO BE 1/4 IN. PER 1 FT.
CLOSURE TRIM PIECE
1/4 IN. SHOP WELDED END PLATE
WITH 1/2 IN. THRU BOLTS (TYPICAL)
C3x4.1 HD GALVANIZED
FRAME RAIL FULL
LENGTH WITH 1/2 IN.
THRU BOLTS (TYPICAL)
26 GA GALVANIZED R-PANEL
WALL. INSTALL FULL LENGTH
HDG HAT CHANNEL SPACER AT
EACH FRAME RAIL TO CLEAR
BOLTS AND NUTS. PRE-DRILL
AND ATTACH HAT CHANNEL TO
EACH FRAME RAIL WITH HDG
SELF TAPPING SCREWS AT 24 IN.
O.C. TOP AND BOTTOM. ATTACH
R-PANEL TO EACH HAT CHANNEL
WITH HDG SELF TAPPING
SCREWS. INSTALL LAP SCREWS.
SHOP WELDC6x8.2
1/4 IN. END PLATE
WITH (4) 1/2 IN.
BOLTS (TYPICAL)
C3x4.1 FULL LENGTH
(TYPICAL)
SHOP WELD L
3 IN. x 3 IN. x 1/4 IN.
(TYPICAL CONNECTION)
(2) 1/2 IN. DIA. BOLTS
(TYPICAL)26 GA GAVLVANIZED
R-PANEL. PRE-DRILL AND
ATTACH TO EACH CROSS
MEMBER WITH HDG SELF
TAPPING SCREWS.
INSTALL LAP SCREWS.
C3x4.1
HSS 4 IN. x 4 IN. x 1/4 IN. (MIN.) GALVANIZED
POSTS. APPROX. 15 FT. - 0 IN. LENGTH (TYPICAL)
6 FT. - 0 IN. (MIN.)
ELECTRICAL EQUIPMENT SHELTER DETAIL - FRONT VIEW
SCALE: N.T.S.
ELECTRICAL EQUIPMENT
SHELTER DETAIL - END VIEW
SCALE: N.T.S.
ROOF AD WALL DETAIL
SCALE: N.T.S.
IH
-
3
5
R
I
A
T
A
L
I
F
T
S
T
A
T
I
O
N
R
E
L
O
C
A
T
I
O
N
A
N
D
OF
F
S
I
T
E
S
E
W
E
R
I
M
P
R
O
V
E
M
E
N
T
S
Te
x
a
s
E
n
g
i
n
e
e
r
i
n
g
F
i
r
m
F
-
1
8
7
1
2
19
1
N
.
U
n
i
o
n
A
v
e
N
E
W
B
R
A
U
N
F
E
L
S
,
T
E
X
A
S
7
8
1
3
0
P
H
:
(
8
3
0
)
2
1
4
-
0
5
2
1
U
E
G
JANUARY 26, 2023
EL
E
C
T
R
I
C
A
L
D
E
T
A
I
L
S
SH
E
E
T
3
LIFT
STATION
ACCESS
HATCH
SS CABLE HOLDER
WITH SS HARDWARE
KELLUM GRIP
LIFT PUMP
CONDUIT
POWER CABLEPUMP CABLE
PUMP CABLE INSTALLATION DETAIL3
N.T.S.
GENERAL NOTES:
1.MAINTAIN MINIMUM SEPARATION REQUIRED UNDER NEC
ARTICLE 504, BETWEEN INTRINSICALLY SAFE CONTROL WIRING
AND NON-INTRINSICALLY SAFE MOTOR FEEDER WIRING.
2.UNLESS OTHERWISE NOTED, ALL NUTS, BOLTS, SCREWS
WASHERS, ETC SHALL BE STAINLESS STEEL.
1LIFT PUMP
TERMINAL
BOX (TYPICAL)
N1
NOTE 1 GROUND
LUG
K
E
(TYP)
G
A
H
(TYP)
M
C
(TYP)
B
(TYP)
F
TO CONTROL PANELFROM WET WELL FLOATS
FROM WET WELL TRANSDUCER
NOTE:
1.PROVIDE REQUIRED NUMBER OF TERMINAL BLOCKS RECOMMENDED
BY LEVEL SENSOR PROBE MANUFACTURER.
2.ROUTE SURGE PROTECTION DEVICE GROUND CONDUCTOR
STRAIGHT PATH TO STRUCTURE STEEL AND TO 20 FT. GROUND ROD.
(TYP)
N
NOTE 2
J
FLOATS/TRANSDUCER/
PRESSURE LEVEL TERMINAL BOX DETAIL2
N.T.S.
5CONDUIT SEAL
(TYPICAL)
CONDUIT SEAL DETAIL4
N.T.S. (TYPICAL)
PUMP CABLE
OR CONDUCTORS
O-Z GEDNEY
TYPE CSBE-SS SEAL
CABLE
THREADED
CONDUIT
LIFT STATION
OR PANEL
NOTE:
1.USE CSBE SEALS IN ALL CONDUITS 1 1/2 IN. AND GREATER AND USE EYS
SEALS FOR LESS THAN 1 1/2 IN. EXCEPT WHERE SHOWN OTHERWISE.
2 IN.
(MAX)
N2
6 I
N
.
6 IN.
3/4 IN. PVC RGS ELBOW WITH
INSULATED BUSHING (BOTH
ENDS) TO GROUND FIELD
ALTERNATE TERMINAL
MOUNTING DETAIL (NOTE 3)
LIFT STATION WET WELL
TOP OF SLAB, LIFT STATION
CONDUIT
SEAL
(TYPICAL)
TERMINAL BOXES MAY BE ATTACHED TO
WET WELL USING CONCRETE ANCHORS
OR MAY BE FREE STANDING WITH MIN. 12
IN. DEEP CONCRETE FITTINGS
3/4 IN.
HOLE
(TYPICAL)
P1000T
UNISTRUT
UNISTRUT
POST BASE
PN P2072A
POST
BASE
SS EXPANSION
TYPE ANCHOR
BOLTS (TYPICAL)
TOP OF
SLAB, LIFT
STATION
NOTES:
1.NAMEPLATES SHALL BE MOUNTED TO
TERMINAL BOXES USING STAINLESS STEEL
HARDWARE.
2.TERMINAL BOX ARRANGEMENT VARIES. SEE
ELECTRICAL PLAN.
3.MOUNT TERMINAL BOX ON TOP OF LIFT
STATION USING POST BASE WHERE TOP OF
LIFT STATION IS FLUSH WITH GRADE.
4.DOOR HINGE ON LEFT ONLY. DO NOT ROTATE
ENCLOSURE.
5.ROUTE SURGE PROTECTION DEVICE GROUND
CONDUCTOR STRAIGHT PATH TO STRUCTURE
STEEL AND TO 10 FT. GROUND ROD.
5
GROUNDING CLAMP
TOP OF
CONCRETE
PAVEMENT
L
(TYP)
(NOTE 1)
NAMEPLATE SCHEDULE
TERMINAL BOX SCHEDULE
A.OZ GEDNEY CSBE SEAL.
B.WATERTIGHT CONDUIT HUB WITH
INSULATED BUSHING.
C.CLASS I, DIV 1, EXPLOSION PROOF SEAL
INSTALLED PER NEC DIV 501.
D.POWER TERMINAL BLOCK W/SCREW DOWN
BOX LUGS.
E.CONTROL TERM BLOCK WITH SCREW DOWN
BOX LUGS.
F.MULTI-CONDUCTOR CABLE, REMOVE
OUTER JACKET AS SHOWN.
G.WIRING AS SCHEDULED.
H.WIRING HARNESS PERMANENTLY AFFIXED.
I.PUMP CONTROL WIRING.
J.CGB FITTING.
K.HOFFMAN NEMA 4X STAINLESS STEEL
JUNCTION BOX WITH GASKETED FRONT
COVER, CONTINUOUS HINGE,
SCREW-DOWN CLAMPS, HASP AND
PADLOCKING PROVISIONS. MINIMUM SIZE: :
12 IN. W x 16 IN. H x 6 IN. D.
L.MICARTA NAMEPLATE, 3/8 IN. HIGH LETTERS
IN WHITE ON BLACK BACKGROUND (SEE
NAMEPLATE SCHEDULE).
M.TRANSDUCER BREATHER.
N.SURGE PROTECTION DEVICE: BLUE RIBBON
CORP. No. BCP3000 SURGE PROTECTOR.
O.SURGE PROTECTION DEVICE: EATON
MODEL No. CVX 100 480Y. SEE ONE-LINE
DIAGRAM FOR VOLTAGE.
BOLTED CONNECTION
CADWELL
CONNECTION
TO TERMINAL BOX
AND GROUND ROD
GROUND CONDUCTOR
(BARE Cu)
TERMINAL BOX INSTALLATION DETAIL5
N.T.S.
RUN/STOP (DS185)
SURGE PROTECTION DEVICE
TO GROUND FIELD
TOP OF
SLAB, LIFT
STATION2
F
T
.
REINFORCED CONCRETE
ENCASEMENT (TYPICAL)
NOTE 5
1 5/8 IN. SS UNISTRUT
MOUNTING FRAME WITH
VERTICAL SUPPORTS
LOCKING HASP
(TYPICAL)
RUN/STOP
(DS185) (TYPICAL)
DESIGNATION ENGRAVED
N1 TRANSDUCER/FLOATS
N2 PUMP NO. 2
N3 PUMP NO. 1
STILLING WELL
CONDUIT STRUT
AND CLAMPS TO
CONTROL PANEL
4
GND
E
(TYP)
D
(TYP)
F
H
(TYP)
K
I
GROUND LUG
NOTE 1
B
(TYP)
C
(TYP)
A
(TYP)
J
3 IN.
(MIN.)
TO CONTROL PANEL
TO PUMP STARTER (POWER)
FROM WET WELL -
PUMP POWER CABLE
NOTE:
1.PROVIDE ADDITIONAL CONDUIT ONLY WHERE PUMP HAS 2 CABLES.
2.ROUTE SURGE PROTECTION DEVICE GROUND CONDUCTOR STRAIGHT
PATH TO STRUCTURE STEEL AND TO 20 FT. GROUND ROD.
3. SURGE PROTECTOR MOUNTED ON BACK OF TERMINAL BOX.
L3 L2 L1
O
NOTE 2
G
LIFT PUMP TERMINAL BOX DETAIL1
N.T.S.
(NOTE 3)
RE
F
.
P
L
A
N
1 FT. - 1/2 IN.
4"
12 IN. DIA. CAST IRON
FRAME AND COVER
STAMPED "SEWER"
SIDE ENTRY CONDUIT
IN SLAB W/BELL END
ADAPTER
TRANSMITTER CABLE
8 IN. SCR26 PVC STILLING
WELL INSTALLED IN
CENTER OF FRAME AND
COVER OPENING, ATTACH
TO WALL W/316 SS
SUPPORTS AT 5 FT.
INTERVALS. USE STRUT
BASE AND STRUT
W/EITHER U-BOLTS OR
PIPE CLAMPS
3/8 IN. DIA. 316
SS HOOK BOLT
W/6 IN. MIN.
EMBEDMENT
SS KELLEMS
TYPE CORD
GRIP
DRILL 1 IN.
VENT HOLE 6 IN.
BELOW ROOF
SLAB
STILLING WELL DETAIL7
N.T.S.
N3
FENCE POST (TYPICAL)
GATE
BURNDY
TYPE "GG"
CONNECTOR
GRADE
FLEXIBLE COPPER
BRAID BURNDY TYPE "BD"
BURNDY TYPE
"GAR" CONNECTOR
GROUND WIRE
(TYPICAL)
FENCE POST AND
GATE ROUNDING DETAIL8
N.T.S.
NOTES:
1.ANY EXPOSED OR ABOVE GRADE CONNECTIONS SHALL BE MECHANICAL TYPE WITH CRIMP LUGS. USE CADWELD FOR BURIED
LOCATIONS.
2.EXOTHERMICALLY WELD ALL BELOW GRADE CONNECTIONS.
3.EXTEND #6 SOFT DRAWN BARE COPPER CABLE UP INTO ATS/EQUIPMENT PANELS AND GROUND TO GROUND BUS.
GROUND ROD
NTS
SECTION "A"
30 IN.
MIN.
GROUND TEST WELL
NTS
12 IN.
6 IN.
4 IN.12 IN.
"A""A"
FINISHED GRADE CAST IRON MONUMENT CASE W/ COVER
NEENAH CAT. No. 4-1978-B OR EQUAL.
PROVIDE IDENTIFICATION TAG AS SHOWN.
FINISHED GRADE
MECHANICAL CONNECTIONS
INDIVIDUAL 4/0 SOFT DRAWN
BARE Cu GROUND CABLES
BURIED MIN. 30 IN. BELOW GRADE.
ATTACH EACH TAIL TO ROD W/
MECHANICAL CONNECTIONS
3/4 IN. x 10 FT. - 0 IN. Cu
WELD GROUND ROD
3/4 IN. x 10 FT. - 0 IN. Cu
WELD GROUND ROD
1 IN.
FORM SQUARE
ALL AROUND
GROUND ROD
GRAVEL FILL
CONCRETE
ALL AROUNDCADWELD
4/0 BARE
Cu WIRE
(TYPICAL)
4/0
4 IN. SQUARE ENGRAVED BRASS IDENTIFICATION TAG.
DRILL AND TAP COVER AND FASTEN W/SS SCREWS.
GROUNDING DETAIL6
N.T.S.
2 FLOATS/TRANSDUCER
TERMINAL BOX (TYPICAL)
IH
-
3
5
R
I
A
T
A
L
I
F
T
S
T
A
T
I
O
N
R
E
L
O
C
A
T
I
O
N
A
N
D
OF
F
S
I
T
E
S
E
W
E
R
I
M
P
R
O
V
E
M
E
N
T
S
Te
x
a
s
E
n
g
i
n
e
e
r
i
n
g
F
i
r
m
F
-
1
8
7
1
2
19
1
N
.
U
n
i
o
n
A
v
e
N
E
W
B
R
A
U
N
F
E
L
S
,
T
E
X
A
S
7
8
1
3
0
P
H
:
(
8
3
0
)
2
1
4
-
0
5
2
1
U
E
G
JANUARY 26, 2023
EL
E
C
T
R
I
C
A
L
D
E
T
A
I
L
S
SH
E
E
T
4
Form ROW-U-35
(Rev. 10/20)
Page 6
______ __________ ______ __________
Initial Date Initial Date
TxDOT Utility
Attachment “B”
Accounting Method
Actual Cost Method of Accounting
The utility accumulates cost under a work order accounting procedure prescribed by the
Federal or State regulatory body and proposes to request reimbursement for actual
direct and related indirect costs.
Lump Sum Method of Accounting
Utility proposed to request reimbursement based on an agreed lump sum amount
supported by a detailed cost analysis.
Project Name and Phase :Riata Lift Station Relocation Project
Owner: City of Schertz
Engineering Firm: Utility Engineering Group, PLLC
Project Number: 8032-01
Wastewater EDUs: Sewer EDUs: Date:2/23/23
Prepared By: David Kneuper
Bid Item Bid Item Description Quantity Unit Unit Price Total Cost
1 MOBILIZATION, BONDS & INSURANCE 1 EA 175,000.00$ 175,000.00$
175,000.00$
1 SILT FENCE 660 LF 3.50$ 2,310.00$
2 STABILIZED CONSTRUCTION ENTRANCE/EXIT 1 EA 2,500.00$ 2,500.00$
3 TREE PROTECTION FENCING (11 TOTAL TREES) 245 LF 5.00$ 1,225.00$
4 TREE REMOVAL 4 EA 250.00$ 1,000.00$
5 SITE RESTORATION & REVEGETATION 4,675 SY 4.00$ 18,700.00$
Subtotal Erosion and Sedimentation Controls 25,735.00$
1 SITE CLEARING & RIGHT-OF-WAY PREPARATION 0.74 AC 10,000.00$ 7,400.00$
2 TRENCH & EXCAVATION SAFETY (PLAN AND IMPLEMENTATION) 760 LF 45.00$ 34,200.00$
3 6" PVC C900 DR 14 FORCE MAIN PIPING 360 LF 110.00$ 39,600.00$
4 8" PVC SDR 26 GRAVITY MAIN PIPING (8' - 25') 400 LF 200.00$ 80,000.00$
5 5' DIA. WW MANHOLE 1 EA 8,500.00$ 8,500.00$
6 5' DIA. DOGHOUSE MANHOLE 1 EA 25,000.00$ 25,000.00$
7 SMARTCOVER SYSTEM (MANHOLE A-2) 1 EA 12,000.00$ 12,000.00$
8 EXTRA DEPTH MANHOLE 20 VF 350.00$ 7,000.00$
9 DUCTILE IRON FITTINGS 0.5 TON 25,000.00$ 12,500.00$
10 CONNECT TO EX. GRAVITY WW MAIN 1 EA 5,500.00$ 5,500.00$
11 CONNECT TO EX. FORCE MAIN 1 EA 2,500.00$ 2,500.00$
12 ABANDONMENT IN PLACE OF EX. GRAVITY MAIN AND MANHOLES 1 EA 20,000.00$ 20,000.00$
13 ABANDONMENT AND REMOVAL OF EX. FORCE MAIN 1 EA 25,000.00$ 25,000.00$
14 ASPHALT PAVEMENT REPAIR (INCL. CURB & GUTTER) 106 SY 250.00$ 26,500.00$
15 BYPASS PUMPING (PLAN AND IMPLEMENTATION) TOTAL PROJECT 1 EA 25,000.00$ 25,000.00$
16 DEWATERING PLAN & IMPLEMENTATION 1 EA 7,500.00$ 7,500.00$
17 MATERIAL TESTING 1 EA 5,000.00$ 5,000.00$
18 HYDROSTATIC TEST 1 EA 3,500.00$ 3,500.00$
346,700.00$
1 SITE CLEARING & RIGHT-OF-WAY PREPARATION 0.42 AC 10,000.00$ 4,200.00$
2
LIFT STATION WET WELL EXCAVATION SAFETY (PLAN AND
IMPLEMENTATION)1 EA 100,000.00$ 100,000.00$
3 LIFT STATION SITE PIPING* 1 EA 35,000.00$ 35,000.00$
4 6" PLUG VALVE W/HAND WHEEL* 2 EA 3,750.00$ 7,500.00$
5 6" CHECK VALVE*3 EA 5,000.00$ 15,000.00$
6 6" PLUG VALVE W/BOX* 2 EA 3,500.00$ 7,000.00$
7 6" EMERGENCY BY- PASS INCLUDING CONCRETE EQUIPMENT PAD* 1 EA 12,500.00$ 12,500.00$
8 COMBINATION AIR/VACUUM RELEASE VALVE* 1 EA 4,500.00$ 4,500.00$
9 DUCTILE IRON FITTINGS 1.00 TON 20,000.00$ 20,000.00$
10 SUBMERSIBLE PUMP* 2 EA 115,000.00$ 230,000.00$
11 12' DIA. PRE-CAST CONCRETE WET WELL - 20.5' DEPTH 1 EA 425,000.00$ 425,000.00$
12 PRE-CAST CONCRETE VALVE VAULT 1 EA 35,000.00$ 35,000.00$
13 LIFT STATION APPURTENANCES* 1 EA 150,000.00$ 150,000.00$
14
EX. LIFT STATION ABANDONMENT (INCLUDING SITE, PAVEMENT, WET
WELL, ELECTRICAL, AND ALL APPURTENANCES DETAILED ON THE DEMO
SHEETS)
1 EA 95,000.00$ 95,000.00$
15 PIPE BOLLARD*14 EA 1,350.00$ 18,900.00$
16 ASPHALT PAVEMENT 826 SY 50.00$ 41,300.00$
17 FLUSH CURB 664 LF 17.50$ 11,620.00$
18 WEED PROTECTION AND ROCK AROUND SITE 1,205 SY 25.00$ 30,125.00$
19 SITE WATER SERVICE* 1 EA 5,500.00$ 5,500.00$
20 SECURITY FENCING 447 LF 75.00$ 33,525.00$
21 SECURITY GATE*2 EA 4,000.00$ 8,000.00$
22 DEWATERING PLAN & IMPLEMENTATION 1 EA 35,000.00$ 35,000.00$
23 MATERIAL TESTING 1 EA 5,000.00$ 5,000.00$
24 HYDROSTATIC TEST 1 EA 7,500.00$ 7,500.00$
25 DEMONSTRATION TESTING 1 EA 10,000.00$ 10,000.00$
26 ELECTRICAL SHELTER INCLUDING CONCRETE FOUNDATION* 1 EA 45,000.00$ 45,000.00$
27 ELECTRICAL, INSTRUMENTATION & CONTROLS, & SITE LIGHTING* 1 EA 265,000.00$ 265,000.00$
28 SCADA TOWER INCLUDING FOUNDATION* 1 EA 25,000.00$ 25,000.00$
29 EMERGENCY GENERATOR INCLUDING CONCRETE FOUNDATION* 1 EA 135,000.00$ 135,000.00$
General
Subtotal General:
Erosion and Sedimentation Controls
Off-Site Utilities
Subtotal Off-Site Utilities:
Preliminary 100% Opinion of Probable Project Costs
Total Project
Riata Lift Station - City of Schertz
Lift Station and Off-Site Utilities Relocation Project
Lift Station
Page 1
Form ROW-U-35
(Rev. 10/20)
Page 7
______ __________ ______ __________
Initial Date Initial Date
TxDOT Utility
Attachment “C”
Schedule of Work
Estimated Start Date: July 10, 2023, (subject to physical work restrictions prior to the
issuance of environmental clearance as required by the provisions of this agreement)
Estimated Duration (days): 420
Estimated Completion Date: September 2, 2024
Form ROW-U-35
(Rev. 10/20)
Page 8
______ __________ ______ __________
Initial Date Initial Date
TxDOT Utility
Attachment “D”
Statement Covering Contract Work
(ROW–U–48)
(ROW–U–48–1, if applicable)
Construction Contract:
Utility performing with their own forces (timesheets will be required at the time of billing).
Utility will use outside forces to perform the adjustment, complete attached ROW-U-48
or ROW-U-48-1 (joint bid).
Engineering Contract:
Utility performing with their own forces (timesheets will be required at the time of billing).
Utility will use consultant contract (continuing contract rate sheets or fee schedule will
be required).
TxDOT will procure utility consultant.
* 48*
Form ROW-U-48
Page 1 of 1
(Rev. 3/19)STATEMENT COVERING UTILITY CONSTRUCTION CONTRACT WORK
(AS APPEARING IN ESTIMATE)
U-Number: U00014203
ROW CSJ Number: 0016-05-116
County: Comal
Federal Project No.: NH 1720(809)
District: San Antonio
Highway No.: IH 35
facts and make the following statements in respect to work which will or may be done on a contract basis as it appears in the
estimate to which this statement is attached.
It is more economical and/or expedient for Owner to contract this adjustment, or Owner is not adequately staffed or equipped
to perform the necessary work on this project with its own forces to the extent as indicate on the estimate.
Solicitation for bids is to be accomplished through open advertising and contract is to be awarded to the lowest
qualified bidder who submits a proposal in conformity with the requirements and specifications for the work to be
performed. Associated bid tabulations will be provided to the State.
Solicitation for bids is to be accomplished by circulating to a list of pre-qualified contractors or known qualified
contractors and such contract is to be awarded to the lowest qualified bidder who submits a proposal in conformity
with the requirements and specifications for the work to be performed. Associated bid tabulations will be provided to
the State. Such presently known contractors are listed below:
A.
Procedure to be Used in Contracting Work
, a duly authorized and qualified representative ofI, Steve Williams
, hereinafter referred to as Owner, am fully cognizant of theCity of Schertz
B.
1.
2.
3.
4.
5.
C.The work is to be performed under an existing continuing contract under which certain work is regularly performed
for Owner and under which the lowest available costs are developed. The existing continuing contract will be made
available to the State for review at a location mutually acceptable to the Owner and the State. If only part of the
contract work is to be done under an existing contract, give detailed information by attachment hereto.
D The utility proposes to contract outside the foregoing requirements and therefore evidence in support of its proposal
is attached to the estimate in order to obtain the concurrence of the State, and the Federal Highway Administration
Division Engineer where applicable, prior to taking action thereon (approval of the agreement shall be considered as
approval of such proposal).
E.The utility plans and specifications, with the consent of the State, will be included in the construction contract
awarded by the State. In the best interest of both the State and the Owner, the Owner requests the State to include
the plans and specifications for this work in the general contract for construction of Highway
in this area, so that the work can be coordinated with the other construction operations; and the construction
contract is to be awarded by the State to the lowest qualified bidder who submits a proposal in conformity with the
requirements and specifications for the work to be performed. If this option is chosen, attach form ROW-U-48-1, the
terms of which are incorporated herein by reference.
DateSignature
Title
City Manager
Form ROW-U-35
(Rev. 10/20)
Page 9
______ __________ ______ __________
Initial Date Initial Date
TxDOT Utility
Attachment “E”
Utility Joint Use Agreement – (ROW-U-JUA) and/or
Utility Installation Request – (Form 1082)
Utility Joint Use Agreement (ROW–U–JUA)
Utility Installation Review/Permit Number:
Form ROW-U-35
(Rev. 10/20)
Page 10
______ __________ ______ __________
Initial Date Initial Date
TxDOT Utility
Attachment “F”
Eligibility Ratio
Eligibility Ratio established: %
Non-interstate Highway (Calculations attached)
Interstate Highway
ROW Utility Manual Chapter 8, Section 2
In developing the ratio, line length or number of poles is restricted to facilities located
within the existing and proposed highway right of way. Facilities located outside the
existing and proposed right of way limits will not be used in developing the ratio.
Please see example of eligibility ratio calculations below.
Plan Sheet or
Page#
In Easement
(Eligible)
Existing # of Poles
or LF
In Public ROW
(Ineligible)
Existing # of Poles
or LF
1 0 0
2 84 22
3 90 385
4 238 96
Totals 412 503
Total Existing # of Poles or LF (Eligible) 412
Total Existing # of Poles or LF (Ineligible) 503
Total Existing # of Poles or LF 915
Total Existing # of Poles or LF (Eligible)
divided by the Total Existing # of Poles or LF 45.03%
Form ROW-U-35
(Rev. 10/20)
Page 11
______ __________ ______ __________
Initial Date Initial Date
TxDOT Utility
Attachment “G”
Betterment Calculation and Estimate
Elective Betterment Ratio established: %
(Calculation attached and justification below)
Forced Betterment
(Provide supporting documentation)
Not Applicable
Elective betterment justification statement:
Form ROW-U-35
(Rev. 10/20)
Page 12
______ __________ ______ __________
Initial Date Initial Date
TxDOT Utility
Attachment “H”
Proof of Property Interest
Supporting documentation of compensable property interest that establishes
reimbursement eligibility as referenced in Texas Transportation Code §203.092.
Property interest documented through applicable affidavits and required
attachments.
ROW-U-Affidavit
The roadway improvement project is designated as an Interstate Highway project;
therefore, no supporting documentation of compensable interest is required.
RESOLUTION NO. 23-R-24
A RESOLUTION BY THE CITY COUNCIL OF THE CITY OF
SCHERTZ, TEXAS, AUTHORIZING THE CITY MANAGER TO ENTER
INTO A STANDARD UTILITY AGREEMENT WITH THE STATE OF
TEXAS FOR THE RELOCATION OF UTILITIES – SPECIFICALLY THE
RIATA LIFT STATION - ALONG IH 35 IN PREPARATION FOR THE
IH 35 NEX PROJECT
WHEREAS, the Texas Department of Transportation (TxDOT) is undertaking the
Interstate Highway 35 North East Expansion (IH 35 NEX) Project and has acquired additional
right of way for the widening of the highway; and
WHEREAS, the Riata Wastewater Lift Station of the City of Schertz, Texas, (City) is
located in conflict with the planned TxDOT improvements to IH 35; and
WHEREAS, the State of Texas will pay to the City of Schertz the costs incurred in
adjustment, removal, and relocation of the Riata Lift Station and Wastewater Mains; and
WHEREAS, City Staff has recommended that the City enter into a Standard Utility
Agreement (SUA) with the State of Texas for the relocation of utilities along Interstate Highway
35 (Riata Lift Station and Associated Gravity and Force Mains) and reimbursement of project
costs.
NOW THEREFORE, BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF
SCHERTZ, TEXAS THAT:
Section 1. The City Council hereby authorizes the City Manager to execute the TxDOT
Standard Utility Agreement in substantially the form set forth as Exhibit A.
Section 2. The recitals contained in the preamble hereof are hereby found to be true, and
such recitals are hereby made a part of this Resolution for all purposes and are adopted as
a part of the judgment and findings of the City Council.
Section 3. All resolutions, or parts thereof, which are in conflict or inconsistent with any
provision of this Resolution are hereby repealed to the extent of such conflict, and the
provisions of this Resolution shall be and remain controlling as to the matters resolved
herein.
Section 4. This Resolution shall be construed and enforced in accordance with the laws
of the State of Texas and the United States of America.
Section 5. If any provision of this Resolution or the application thereof to any person or
circumstance shall be held to be invalid, the remainder of this Resolution and the
application of such provision to other persons and circumstances shall nevertheless be
valid, and the City Council hereby declares that this Resolution would have been enacted
without such invalid provision.
Section 6. It is officially found, determined, and declared that the meeting at which this
Resolution is adopted was open to the public and public notice of the time, place, and
subject matter of the public business to be considered at such meeting, including this
Resolution, was given, all as required by Chapter 551, Texas Government Code, as
amended.
Section 7. This Resolution shall be in force and effect from and after its final passage,
and it is so resolved.
PASSED AND ADOPTED, this 14th day of March, 2023.
CITY OF SCHERTZ, TEXAS
Ralph Gutierrez, Mayor
ATTEST:
Sheila Edmondson, Interim City Secretary
(city seal)
Exhibit “A”
Agenda No. 6.
CITY COUNCIL MEMORANDUM
City Council
Meeting:March 14, 2023
Department:Executive Team
Subject:
Ordinance 23-S-07- Consideration and/or action by the City Council of the City of
Schertz, Texas on an Ordinance to amend Part III, Schertz Code of Ordinances,
the Unified Development Code (UDC) Article 5 Zoning Districts, Subsections
21.5.2, 21.5.5 and 21.5.11; Article 9 Site Design Standards, Subsection 21.9.7 and
21.9.10; Article 10 Parking Standards, Subsections 21.10.2, 21.10.3, 21.10.4,
21.10.7.C and 21.10.9; and Article 14 Transportation, Subsection 21.14.3. (Final
Reading) (B. James/S. Williams)
BACKGROUND
At the March 7, 2023 Council meeting, City council conducted a public hearing and considered a
number of amendments to multiple sections of the City's Unified Development Code (UDC). There was
a lack of agreement among all members of Council on each of the proposed amendments. Council
ultimately approved the proposed amendments on 3 different votes, as different members
supported/opposed two of the proposed amendments. As such, staff is proposing Council take 3 votes
on the proposed amendment.
The first vote is on the proposed amendment to Section 21.10.3 A Size of Parking Space and
Section 21.10.9 Additional regulations and illustrations - C. 90o parking dimensions, D. Angle parking
dimensions E. Drive aisle dimensions. These amendments change the minimum parking space size
from 10' x 20' to 9' x 18'.
The second vote is on Section 21.10.4 Schedule of off-street parking requirements for multifamily,
duplex, two-family, condominiums or other similar uses to change the required number of parking
spaces for multifamily, duplex, two-family, condominium or other similar uses. Currently, the UDC
requires 1.5 spaces per 1 bedroom, 2 spaces per 2 bedroom unit, 2.5 spaces per and an additional 5% for
guest parking. The proposed amendment requires 1.7 spaces per unit plus an additional 5% for guest
parking. Staff is going to make clear that duplex/two-family require 2 spaces per unit (the same as is
required for single family).
The third vote will consider the remainder of the changes to the UDC. The proposed change amends
Section 21.5.5 Statement of Purpose and Intent for Residential Districts and 21.5.2 Zoning Districts
Established to eliminate the current prohibition on granting new R-6 and R-7 single family zoning. The
R-6 District allows for a minimum lot size of 7,200 square feet and the R-7 District allows for a
minimum lot size of 6,600 square feet. The granting of new zoning to these two zoning districts was
prohibited by City Council in 2010. The proposed change also amends Section 21.5.11 Specific Use
Permit (SUP) to eliminate the requirement for a site plan. It does provide that a site layout, less detail
than a site plan, can be required by the Planning and Zoning Commission if they deem it necessary to
mitigate adverse effects of the proposed use. After the Planning and Zoning Commission consideration
and changes the requirement to pull a building permit be extended from one to two years, lest the SUP
expire.
expire.
A major overhaul is proposed to Article 9, Site Design Standards, Section 21.9.7 Landscaping.
Currently, Section 21.9.7 Landscaping is 10 pages long. With the proposed revisions it has been
reduced to 3 pages. The proposed changes separate the requirements for single family and duplex
development from the requirements for nonresidential and multifamily residential development for
clarity. Much of the reduction in length of section is the result of eliminating the Approved Landscape
Planting List. This will allow builders, developers and landscape architects to select the most
appropriate plants for their project. The changes also decrease and adjust the requirements for
landscaping for commercial projects. The change also incorporates modified standards from Section
21.14.3 Additional Design Requirements, that impact landscaping, to avoid confusion and problems that
arise from developers not being aware of these requirements. Staff did combine the screening and
buffering requirements into one section. There are a few other changes to wheel stops, parking
requirements for older sites that expand and stacking for a bank drive-thru.
GOAL
To amend the UDC to review and update the development regulations due to changing conditions and
community goals in order to establish and maintain sound, stable and desirable development.
COMMUNITY BENEFIT
It is the City's desire to promote safe, orderly, efficient development and ensure compliance with the
City's vision of future growth.
SUMMARY OF RECOMMENDED ACTION
First motion and vote - Approval of the proposed amendment to Section 21.10.3 A Size of Parking
Space and Section 21.10.9 Additional regulations and illustrations - C. 90o parking dimensions, D.
Angle parking dimensions E. Drive aisle dimensions to change the minimum parking space size from
10' x 20' to 9' x 18'.
Second motion and vote - Approval of the proposed amendment to Section 21.10.4 Schedule of
off-street parking requirements for multifamily, duplex, two-family, condominiums or other similar use
to required 1.7 parking spaces per unit plus an additional 5% for guest parking for multifamily,
condominium and similar uses and to require 2 spaces per duplex/two-family unit.
Third motion and vote - Approval of the remainder of the proposed changes to the UDC.
RECOMMENDATION
Approval of Ordinance 23- S-07.
Attachments
Ord 23 S 07
Ord. 23-S-07
ORDINANCE NO. 23-S-07
AN ORDINANCE BY THE CITY COUNCIL OF THE CITY OF SCHERTZ, TEXAS TO
AMEND PART III, SCHERTZ CODE OF ORDINANCES, THE UNIFIED
DEVELOPMENT CODE (UDC) ARTICLE 5 ZONING DISTRICTS, SUBSECTIONS
21.5.2, 21.5.5, AND 21.5.11, ARTICLE 9 SITE DESIGN STANDARDS, SUBSECTION
21.9.7, ARTICLE 10 PARKING STANDARDS, SUBSECTIONS 21.10.2, 21.10.3, 21.10.4,
21.10.7.C, 21.10.9 AND ARTICLE 14 TRANSPORTATION, SUBSECTION 21.14.3
WHEREAS, pursuant to Ordinance No. 10-S-06, the City of Schertz, Texas (the “City) adopted
as Amended and Restated Unified Development Code on April 13, 2010, as further amended (the
“Current UDC”); and
WHEREAS, City Staff has reviewed the Current UDC and have recommended certain revision
and updates to, and reorganization of, the Current UDC;
WHEREAS, on December 14, 2022 and January 11, 2023, the Planning and Zoning
Commission conducted public hearings and, thereafter recommended approval; and
WHEREAS, on March 7, 2023, the City Council conducted a public hearing and after
considering the Criteria and recommendation by the Planning and Zoning Commission,
determined that the proposed amendments are appropriate and in the interest of the public safety,
health, and welfare.
BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF SCHERTZ, TEXAS:
THAT:
Section 1. The current UDC is hereby amended as set forth on Exhibit A hereto.
Section 2. The recitals contained in the preamble hereof are hereby found to be true, and
such recitals are hereby made a part of this Ordinance for all purposes and are adopted as a part
of the judgment and findings of the Council.
Section 3. All ordinances and codes, or parts thereof, which are in conflict or
inconsistent with any provision of this Ordinance are hereby repealed to the extent of such
conflict, and the provisions of this Ordinance shall be and remain controlling as to the matters
resolved herein.
Section 4. This Ordinance shall be construed and enforced in accordance with the laws
of the State of Texas and the United States of America.
Section 5. If any provision of this Ordinance or the application thereof to any person or
circumstance shall be held to be invalid, the remainder of this Ordinance and the application of
such provision to other persons and circumstances shall nevertheless be valid, and the City
hereby declares that this Ordinance would have been enacted without such invalid provision.
Section 6. It is officially found, determined, and declared that the meeting at which this
Ordinance is adopted was open to the public and public notice of the time, place, and subject
matter of the public business to be considered at such meeting, including this Ordinance, was
given, all as required by Chapter 551, as amended, Texas Government Code.
Section 7. This Ordinance shall be effective upon the date of final adoption hereof and
any publication required by law.
Section 8. This Ordinance shall be cumulative of all other ordinances of the City of
Schertz, and this Ordinance shall not operate to repeal or affect any other ordinances of the City
of Schertz except insofar as the provisions thereof might be inconsistent or in conflict with the
provisions of this Ordinance, in which event such conflicting provisions, if any, are hereby
repealed.
Approved on first reading the 7th day of March, 2023.
PASSED, APPROVED AND ADOPTED on final reading the 14th day of March, 2023.
____________________________________
Ralph Gutierrez, Mayor
ATTEST:
________________________________
Sheila Edmondson, City Secretary
(SEAL OF THE CITY)
Exhibit “A”
Agenda No. 7.
CITY COUNCIL MEMORANDUM
City Council
Meeting:March 14, 2023
Department:Executive Team
Subject:The City Council will meet in closed session in accordance with Section 551.072,
Texas Government Code deliberation regarding the purchase, exchange, lease,
or value of Real Property for future roadways, roadway extensions, and roadway
expansions.