Loading...
Addendum No. 4 for Animal Adoption CenterADDENDUM NO.4 To Drawings and Specifications dated September 26, 2012 for City of Schertz - Animal Adoption Center Prepared By: O'Neill Conrad Oppelt Architects, Inc. Addendum Date: November 27, 2012 060 architects 01111�1M. This addendum shall be considered part of the Contract Documents for the above - mentioned project as though it had been issued at the same time and shall be incorporated integrally therewith. Where provisions of the following supplementary data differ from those of the original Contract Documents, this Addendum shall govern and take precedence. Bidders are hereby notified that they shall make any necessary adjustment in their estimates on account of this addendum. It will be construed that each Bidder's proposal is submitted with full knowledge of all modifications and supplemental data specified herein. CLARIFICATIONS: Item Reference Description C4 -1 Flat Screen TV Brackets Brackets are based on LG LSW200BG EX Slim Wall Mount A. or an equal to this bracket. Refer to S2 -10 in Addendum S4 -2 Section 08 9100, 2.01, #2 for more detail. C4 -2 Sheet A6.1 & Section 08 If there is a conflict between Sheet A6.1 & Specifications S4 -3 7100 Door Opening List 08 7100, the Door Type and Door Frame for all doors C., 12. should follow what is shown on the Door Schedule on S4 -4 Section 00 1105, 3.05, Sheet A6.1. C4 -3 Corner Guards Corner guards will be installed at all gypsum board S4 -5 Section 27 1000, 1.01, outside corners. C4 -4 Polymer Floor Base In Adoption 117 and Stray Dogs 134, there will be an S4 -6 Section 27 1000, 5.01 integral polymer base. C4 -5 Division 27 There intent of the client is to have (4) four separate colors Specifications of cable; voice, data, video, wireless AP. The cables can be routed in one cable support system and not each in se arate J- hooks. SPECIFICATIONS: Item Reference Description S4 -1 Section 10 7500, 2.01, Add "5. Eder Flag Manufacturing Co.: ederflagnews.com" A. as an acceptable manufacturer. S4 -2 Section 08 9100, 2.01, Add "4. Ruskin Manufacturing: ruskin.com" as an A. acce table manufacturer. S4 -3 Section 09 5100, 2.01, Add text "or equal, from approved manufacturers." at C., 12. end of sentence. S4 -4 Section 00 1105, 3.05, Replace following text "Fire Station." with "Animal A., 18. Adoption Center. ". S4 -5 Section 27 1000, 1.01, Replace following text "Coma) Independent School A. District." with "Schertz Animal Adoption Center. ". S4 -6 Section 27 1000, 5.01 Delete in its entirety "Related Work: This section is Division '7 specification and as such will be taken as an integral part of other Division 17 sections, including Section 17010 "General Requirements for Telecommunications Work "." P: \1120 COS Animal Care Facility \Construction Phase \Addenda \Add 4 \ADDENDA NO 004.docx DRAWINGS: ARCHITECTURAL 060 architects 01111� COMM OPWArdgwk.1M. Item Reference Description D4 -1 Detail 2/A1.1 Concrete pad for dumpster enclosure should read "6" CONC. SLAB" in lieu of 7" CONC. SLAB ". D4 -2 Sheet A6.3 Diagonal hatched areas represent where infill panels are located in storefront per Spec. Section 08 4313, 2.03, B.. D4 -3 Sheet A2.1 The window type for Dog Display 107 is "W4 ". END OF ADDENDUM NO. 4 P: \1120 COS Animal Care Facility \Construction Phase \Addenda \Add 4 \ADDENDA NO 004.docx