ORDINANCE NO. 175 , . , !Nt(; '>" ORDINANCE NO. /75 AN ORDmNANCE AMENDING CHAPTER 13, SUBSECTION 13.2.1 of THE PLUMBING CODE OF THE CITY OF SCHERTZ, TEXAS B~ IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF SCHERTZ, TEXAS: SECTION 1. Chapter 13, Section 13.2.1 of the Plumbing Code of the City of Sehertz, Texas is hereby amended to read as follows: :".Section 13.2.1 Calked Joints: Calked joints for cast iron bell and spigot soil pipe shall be firmaly packed with oakum or hemp., and filled with molten lead not less than 1 inch deep and not to extend more than 1/8 inch below the rim of the hub. "ln' lieu of tee above method NEOPRENE gaskets may be used, provided the same conform to ASTMC 564, as a subsititute for the molten lead method above described. No paint, varnish, or other coating shall be permitted on the jointing material until after the joint has been tested and approved. PASSED AND APPROVED this the~~ay of April, 1968. Q~~ ATTEST ~,if R ~bQ{k CITY SECRETARY