Loading...
SEWER DTLS 08-1-2016CUT BACK 1/3 OF PVC ABOVE THE CENTERLINE OF INCOMING PIPE. 3/4" WIDE STAINLESS STEEL STRAP W /CONCRETE ANCHORS (3/8" x 3 1/2 ") DYNA SYSTEM # 098 -0 -2151 OR APPROVED EQUAL. 1 1/4" BOLD LETTER, RASIED 1/ "" LETTERS ARE 1/4" WIC "CITY OF SCHERT I1 • : , I m, 1 1/2" (4) 5/8" DIA. BOLT HOLES (DRILLED AND TAPPED) e 1. 0 a A d PROVIDED. THE TOTAL HEIGHT OF THE ADJUSTMENT RINGS SHALL lI 3. MANHOLE WALL THICKNESS FOR DEPTH EXCEEDING 12' SHALL BE Q ry DETERMINED TO MEET LOADING CONDITIONS (MIN 5 "). " (MIN) 4. H 5. OMIT CEMENT MORTAR WHEN MANHOLE IS LOCATED IN PAVED TI- 6. MINIMUM REINFORCING IN THE PRECAST CONCRETE BASE SHALL BE #5 @8EW. 7. PROVIDE BACKFILL IN ACCORDANCE WITH SPEC 02317.3.11 AROUND PIPES INITIAL BACKFILL AND EMBEDMENT. FOR SECONDARY BACKFILL AND AROUND MANHOLE BELOW PAVED AREAS, ENCAPSULATE MANHOLE WITH CEMENT STABILIZED SANDOR FLOWABLE FILL; A TO REMAIN OPEN SEE TYPICAL DETAIL FOR MANHOLE CONSTRUCTION SANITARY SEWER TEE PRESSURE GASKET �- SANITARY SEWER PIPE / PIPE DIA. w TO MATCH Q 0 o UPSTREAM 2 PIPE. � Of c� foBEND - 12" BRICK 0 a- w SUPPORT _ o - A COVER FACE 3 3/4" 2) TYPE 4 STEEL 'ICK BARS 3/4" /8 " R. �1 R. 2 3 3/8 1" DIA. STEEL ROD 5/16" BUNA -O -RING GASKET ASTM C -443 23" O -RING SEAT (4' 5 /8" DIA. x 1 314" S-1- NLESS S1 -F:FL_ BOL_-1-S 24 1/2" DIA. BOL_ -1- CIRCLE WATERTIGHT AND PICK BAR DETAIL 0 0 FRAME TOP VIEW 2 9/16" 0 I to) Tki0ls T-AT a1 1 7/8" 3/4" 1" 31 7/8 6 1 / " 1 1 /4" 1/8"1 1 1/2" 3 5/8" COVER SECTION v MACHINED BEARING SURFACE -- 33 1/4" DIA 32 3/16" DIA 1 1/2" 30" DI 33 15/16" 91 A—� 3/4" 40 3/4" DIA FRAME SECTION MANHOLE RING AND COVER DETAIL 31 7/8 1 1/2 30 40 3/4 32 3/8 4 1/2 V- 1420/1480 CEMENT MORTAR A MINIMUM OF TWO AND A --- - MAXIMUM OF FOUR THROAT RINGS SHALL BE USED AT EACH MANHOLE. CLASS "A" CONCRETE 3000 PSI IN 28 DAYS A e d d a BACKFILL AROUND MANHOLE SHALL BE JETTED. NO TAMPING ° ALLOWED. NO COLD JOINTS. ° CONCRETE GROUT MANHOLE RING AND COVER OR WATERTIGHT MANHOLE RING AND COVER VARIES 6" MIN d ° 5.0' . f L• ° r PRESS SEAL G SKET INSTALL WITH POWER ISLEEVE EXPANSION ASTM C -923 8" MIN ° T 2.0' 4 1.0' AOQ............. a.......S ............... :..... �...... :.............._s #4 BARS @ 12" O.C. EACH WAY 7.33' MIN STANDARD MONOLITHIC MANHOLE GENERAL MANHOLE NOTES: 1. MATERIAL FOR SANITARY SEWER PIPE MUST BE THE SAME FROM MANHOLE TO MANHOLE. CHANGES IN TYPE OF PIPE MAY BE MADE ONLY AT MANHOLES, OR SPECIAL STRUCTURES, EXCEPT AS APPROVED BY THE ENGINEER. 2. ADAPTORS SHALL BE USED AS DIRECTED BY THE ENGINEER 3. CONCRETE COLLARS TO BE PROVIDED AT ALL NEW PIPE CONNECTION TO THE MANHOLE 4. WATERTIGHT MANHOLE RINGS AND COVERS SHALL BE TRANS -TEX A77 "0" RING OR APPROVED EQUAL. 5. PROVIDE BACKFILL IN ACCORDANCE WITH SPEC 02317.3.11 AROUND PIPES INITIAL BACKFILL AND EMBEDMENT. FOR SECONDARY BACKFILL AND AROUND MANHOLE BELOW PAVED AREAS, ENCAPSULATE MANHOLE WITH CEMENT STABILIZED SAND OR FLOWABLE FILL; A MINIMUM OF 1 -Ff. BELOW BASE, MINIMUM 1 -FT. AROUND WALLS, UP TO WITHIN 12 -INCH OF PAVEMENT 2" SUBGRADE PER SPECIFICATION 02317; IN UNPAVED AREAS USE SELECT FILL PER SPECIFICATION 02317. 6. BASE EXTENSION MAY BE OMITTED WHERE UNDERGROUND WATER IS NOT ENCOUNTERED. 4' - 9" DIA OR SQUARE 12" 33 1/2" 2" FOR NON -PAVED OR CLASS "B" CONCRETE ---- FLUSH WITH PAVEMENT 6" MIN 1-1 ° IH 1 BELOW TOP F --1 ° 1- --1 IF-1 a �a 9" MIN CONCRETE a ° a ENCASEMENT MANHOLE SURFACE COATED WITH TROWEL MASTIC NO. 710 -23 APSHALT ASBESTOS FIBER FLINTKOTE, OR EQUAL, AS APPROVED AND AS DIRECTED BY THE ENGINEER (1/8" THICKNESS, MIN.) n 4' - 9" DIA OR SQUARE / U z 0 �0 � w Of W NOTE: MANHOLE RING ENCASEMENT IS REQUIRED ON ALL MANHOLES. PAYMENT FOR MANHOLE RING ENCASEMENT SHALL BE INCLUDED IN THE COST OF THE MANHOLE MANHOLE RING ENCASEMENT DETAIL 1 " /FT MIN (TYPIC RESILI CONNE (TYPI( 6" BASE E: RESILIENT CONNECTOR (TYPICAL) FOUNDATION PLAN 13" VARIES A ° NOTES: 1. 0 2. MINIMUM OF 2 PRECAST CONCRETE OR HDPE RINGS SHALL BE PROVIDED. THE TOTAL HEIGHT OF THE ADJUSTMENT RINGS SHALL lI 3. MANHOLE WALL THICKNESS FOR DEPTH EXCEEDING 12' SHALL BE Q ry DETERMINED TO MEET LOADING CONDITIONS (MIN 5 "). " (MIN) 4. H 5. OMIT CEMENT MORTAR WHEN MANHOLE IS LOCATED IN PAVED NOTE: MANHOLE RING ENCASEMENT IS REQUIRED ON ALL MANHOLES. PAYMENT FOR MANHOLE RING ENCASEMENT SHALL BE INCLUDED IN THE COST OF THE MANHOLE MANHOLE RING ENCASEMENT DETAIL 1 " /FT MIN (TYPIC RESILI CONNE (TYPI( 6" BASE E: RESILIENT CONNECTOR (TYPICAL) FOUNDATION PLAN 13" VARIES A ° NOTES: 1. DEPTH OF MANHOLE DETERMINES SECTIONS REQUIRED. 2. MINIMUM OF 2 PRECAST CONCRETE OR HDPE RINGS SHALL BE PROVIDED. THE TOTAL HEIGHT OF THE ADJUSTMENT RINGS SHALL NOT EXCEED 21". 3. MANHOLE WALL THICKNESS FOR DEPTH EXCEEDING 12' SHALL BE DETERMINED TO MEET LOADING CONDITIONS (MIN 5 "). " (MIN) 4. SEAT MANHOLE FRAME IN SEALANT. 5. OMIT CEMENT MORTAR WHEN MANHOLE IS LOCATED IN PAVED AREAS. 6. MINIMUM REINFORCING IN THE PRECAST CONCRETE BASE SHALL BE #5 @8EW. 7. PROVIDE BACKFILL IN ACCORDANCE WITH SPEC 02317.3.11 AROUND PIPES INITIAL BACKFILL AND EMBEDMENT. FOR SECONDARY BACKFILL AND AROUND MANHOLE BELOW PAVED AREAS, ENCAPSULATE MANHOLE WITH CEMENT STABILIZED SANDOR FLOWABLE FILL; A MINIMUM OF 1 -FT. BELOW BASE, MINIMUM 1 -FT. AROUND WALLS, UP TO WITHIN 12 -INCH OF PAVEMENT SUBGRADE PER SPECIFICATION 02317; IN UNPAVED AREAS USE SELECT FILL PER SPECIFICATION 02317. IDENTICAL SECTION CEMENT MORTAR 32" DIA STANDARD MANHOLE CONCENTRIC TRANSITION (SEE NOTE 6) FRAME AND COVER SECTION ZF / -SEE NOTE 4 IL SEE NOTE 5 8. TO PROVIDE A WATERTIGHT SEAL, ALL MANHOLE JOINTS SHALL BE SEALED WITH A MINIMUM NINE (9) INCH WIDE EXTERIOR WRAP MEETING SPECIFICATION 02082 AND INSTALLED ACCORDING TO MANUFACTURER'S RECOMMENDATIONS. 9. APPROVED MANUFACTURER SPRAY LINERS ARE REQUIRED IN ALL MANHOLES. SPEC 02081 ° 5'0" TO 8'0" DIA PRECAST OR PREMIX CONCRETE INVERT A d ° d PRECAST CONCRETE BASE SECTION ° PROVIDE 6" BASE EXTENSION (TYPICAL) EXTERNAL WRAP /SEALING MATERIAL /TROWELLED MASTIC PER SPEC 02082 MINIMUM 2 ADJUSTMENT RINGS TO BE COMBINED AS NECESSARY (SEE NOTE 2) AND SEALED WITH APPROVED SEALANT 12„ d s a ° FOUNDATION MATERIAL PER Sit 12" PUBLIC WORKS SPECIFICATION I SANITARY SEWER 5'0" TO 8'0" DIAMETER PRECAST CONCRETE MANHOLE (NOT TO SCALE) OSHA TRENCH SAFETY 1. TRENCH EXCAVATION SHALL COMPLY WITH MINIMUM STANDARDS AS SET FORTH BY THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, REGULATIONS STANDARDS - 29 CFR - "EXCAVATION" - 1926 SUBPART P. 2. TRENCH SAFETY SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE SHOP DRAWINGS FOR DETAIL PLANS AND SPECIFICATIONS TO PROVIDE ADEQUATE SHORING AND SHEETING STANDARDS THAT MEET THE OSHA STANDARDS AS SET OUT BY STANDARDS - 29 CFR - EXCAVATION" - 1926 SUBPART P FOR TRENCH N_\911ra 3. CONTINUOUS INSPECTION OF ALL TRENCH EXCAVATION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR JOB SUPERINTENDENT. THE CONTRACTOR CONTROLS THE SIZE, WEIGHT, AND SPEED OF OPERATION OF EQUIPMENT AND PIPE INSTALLATION, WHICH DIRECTLY AFFECTS ALL SAFETY MEASURES IN A TRENCH. IF PROBABLE CAUSE OF UNSAFE TRENCH CONDITIONS EXIST, ALL WORK SHALL CEASE IMMEDIATELY UNTIL NECESSARY PRECAUTIONS TO SAFEGUARD EMPLOYEES ARE TAKEN. 01 A2G222 2.012 TCEO RULES AND REGULATIONS LAC TITLE 30 PART I CHAPTER 217.53.D "SEPARATION DISTANCES ". WHEN NEW SANITARY SEWERS ARE INSTALLED, THEY SHALL BE INSTALLED NO CLOSER TO WATERLINES THAN NINE FEET IN ALL DIRECTIONS. SEWERS THAT PARALLEL WATERLINES MUST BE INSTALLED IN SEPARATE TRENCHES. WHERE THE NINE FOOT SEPARATION DISTANCE CANNOT BE ACHIEVED, THE FOLLOWING GUIDELINES WILL APPLY. (A) WHERE A SANITARY SEWER PARAL_L -ILS A WATERLINE, THE SEWER SHALL_ BE CONSTRUCTED OF CAST IRON, DUCTILE IRON, OR PVC MF:FTING ASTM SPECIFICATIONS WITH A PRESSURE RATING FOR BOTH THE PIPE AND JOINTS OF 150 PSI. THE VERTICAL SEPARATION SHALL BE A MINIMUM OF TWO FFFF BETWEEN OUTSIDE. [DIAMETERS AND THE HORIZONTAL SFPARATION SHALL_ RE A MINIMUM OF FOUR FEET BF TWEFN OUTSIDE DIAMF FERS. THE SEWER SHALL BE L_OCATFD BELLOW THE WATERLINE. (B) WHERE A SANITARY SEWER CROSSES A WATERLINE AND THE SEWER IS CONSTRUCTED OF CAST IRON, DUCTILE IRON, OR PVC WITH A MINIMUM PRESSURE RATING OF 150 PSI, AN ABSOLUTE MINIMUM DISTANCE OF SIX INCHES BETWEEN OUTSIDE DIAMETERS SHALL BE MAINTAINED. IN ADDITION, THE SEWER SHALL BE LOCATED BELOW THE WATERLINE WHERE POSSIBLE AND ONE LENGTH OF THE SEWER PIPE MUST BE CENTERED ON THE WATERLINE. (C) WHERE A SEWER CROSSES UNDER A WATERLINE AND THE SEWER IS CONSLRLI OF ABS TRUSS PIPE, SIMILAR SEMI —RIGID PLASTIC COMPOSITE PIPE, CLAY PIPE, OR CONCRETE PIPE WITH GASKFTF.ID JOINTS, A MINIMUM TWO—FOOT SEPARATION DISTANCF SHALL BE MAINTAINED. THT_ INITIAL BACKFILL SHALL BE CEMENT STABILIZED SAND (TWO OR MORE BAGS OF CEMENT PER CUBIC YARD OF SAND) FOR ALL SECTIONS OF SEWER WITHIN NINE FFFF OF -THE WATERL_INK. THIS INITIAL BACKFIL_i_ SHALL BF, FROM ONE QUARTER DIAMETER BELOW THE CENTERLINE OF THE PIPE TO ONE PIPE DIAMETER (BUT NOT LESS THAN 12 INCHES) ABOVE THE TOP OF THE PIPE. (D) WHERE A SEWER CROSSES OVER A WATERLINE, AL_L PORTIONS OF THE SFWFR WITHIN NINE FEE[ OF THE WATERLINE SHALL_ BE CONSTRUCTED OF CAST IRON, DUCTILE IRON, OR PVC PIPE WITH A PRESSURE: RATING OF AT FAST 150 PSI USING APPROPRIATE ADAPTERS. IN I_iF_U OF -THIS PROCEDURE THE NEW CONVEYANCE MAY BE ENCASED IN A JOINT OF 150 PSI PRESSURE. CLASS PIPE. AI !--FAST- 18 FFFT i-_ONG AND TWO NOMINAL SIZES LARGER THAN THE NEW CONVEYANCE. TIFF SPACE AROUND THE CARRIER PIPE SHALL BE SUPPORTED AT FIVE FEET INTERVALS WITH SPACERS OR BE FILLED TO THE SPRING LINE WITH WASHED SAND. THE. FNCASFMENT PIPE SHOULD BF CENTERED ON THE CROSSING AND BOTH FINDS SFAI_FD WITH CEMENT GROUT OR MANN G2UND -� ,- 4.0' PROPOSED WATER LINE 9' MIN SEE TCEQ RULES ON SEPARATION DISTANCES •l' 1119 W, : 101 x w x : TYPICAL SANTIARY SEWER /WATER MAIN CROSSING D ETAI L Ir ANCHOR STRAPS NOTE: ALL CONCRETE USED FOR THRUST BLOCKING SHALL HAVE A MINIMUM CONCRETE STRENGTH OF 3500 PSI. TYPICAL THRUST BLOCKING (SEWER ONLY) %owmelm pov, FTAI R-m 1.24 lo KIM - 0. 1: TRENCH WALLS MUST BE VERTICAL TACK COAT BETWEEN EXISTING AND NEW PAVEMENT • 'E OF3 "TO D GRAVEL ING ZONE* * SEWER GRAVEL 6" MIN. OR 1/8 O.D. OF THE PIPE, WHICHEVER IS GREATER AS DIRECTED BY THE INSPECTOR k, 9 I'll I w 9 F, " 1604, ill anal IN 113 1 0 PAY LIMITS 6" MIN 6� "MIN O.D. -•� _ a I �a� v I C) I a O.D. v I a b 6" MIN A CLASS "B" CONCRETE -_ COVER c3.1717h[e3 NOT TO SCALE #4 BARS PAY LIMITS 1' 1' MIN-1—MIN SECTION A —A CONCRETE JOINTING COLLAR PAY LIMITS D. v a _+ c " MIN i" MIN CONCRETE COVER FOR FLEXIBLE PIPE 1.0 BE USED WHEREVER .TRENCH WID -T I- -1 IS GRIL =AT ER i I AN -TWO 'EEi (2') PLUS O.D. AFTER CENTERING PIPE ENDS, WRAP JOINTS WITH S" WIDE. POL_YVINL_Y TAPE OR RUBBER ADAPTER, CAN TEX. 1­70A OR EQUAL PIPE SECTIONS TO BE BLOCKED AND SUPPORTED SIMILAR TO THE ENCASEMENT DETAIL SHOWN BEI OW, (SUBJECT TO APPROVAL--) PAY LIMITS 6" MIN PAY 6" MIN ° LIMITS T ° ° VARIES a NOTE: ALL CONCRETE ENCASEMENT SHALL BE POURED AT A PLANE 6" ABOVE THE PIPE BETWEEN EXCAVATED TRENCH WALLS TYPICAL CONCRETE ENCASEMENT DETAILS *ONLY RAVEN 400, SPRAYROQ, SPRAYWALL & SEWPERCOAT ALLOWED AS SPRAYLINERS (SPEC 0281). - 5' MIN PIPE O.D. 5' MIN 12" MIN 12" MIN i WE J ( � Q � U ry 48" MIN. Ld > m V I Z J `— z U z W PAVED AREA TRENCH DETAIL SPEC -01731 (NOT TO SCAE� PAY LIMITS 6" MIN 6" MIN a PAY O.D. ° + LIMITS a ( a •° 4 v ° a 6" MIN PAVEMENT SURFACE COURSE (3" HMAC TYPE "D" MIN) TACK COAT BETWEEN EXISTING AND NEW PAVEMENT TACK COAT PRIME COAT PAVEMENT BASE MATERIAL (6" ATB MIN) 14 GA. SOLID CORE DETECTION WIRE TAPED TO PIPE. RING MADE FP""" 1/2" STEEL PL, TRIM ENDS OF ANGLES TO FIT MAIlill IIL Lei L■IaIEd1:1 PAY LIMITS 6" MIN O.D. a +- PAY LLIMITS ° 4 4 d. 6" MIN CONCRETE ENCASEMENT END VIEW • 60m, 0 1111 to] 00 CONCRETE CRADLE 1/4" DI, NOTES: ' 1• I KITIN • FITTINGS SIX INCHES (6 ") TO FIFTEEN INCHES (15 ") IN DIAMETER SHALL CONFORM TO ASTM D -3034. PVC PIPES AND FITTINGS EIGHTEEN INCHES (18 ") TO TWENTY —SEVEN INCHES (27 ") IN DIAMETER SHALL CONFORM TO ASTM F -679. THIS INFORMATION IS PROVIDED AS A REFERENCE. ALL DEFLECTION TESTING SHALL BE DONE IN ACCORDANCE WITH TCEQ RULES AND REGULATIONS, TAC TITLE 30 PART I CHAPTER 217.57. MAIlill IIL Lei L■IaIEd1:1 PAY LIMITS 6" MIN O.D. a +- PAY LLIMITS ° 4 4 d. 6" MIN CONCRETE ENCASEMENT END VIEW • 60m, 0 1111 to] 00 CONCRETE CRADLE 1/4" DI, NOTES: PVC PIPES AND FITTINGS SIX INCHES (6 ") TO FIFTEEN INCHES (15 ") IN DIAMETER SHALL CONFORM TO ASTM D -3034. PVC PIPES AND FITTINGS EIGHTEEN INCHES (18 ") TO TWENTY —SEVEN INCHES (27 ") IN DIAMETER SHALL CONFORM TO ASTM F -679. THIS INFORMATION IS PROVIDED AS A REFERENCE. ALL DEFLECTION TESTING SHALL BE DONE IN ACCORDANCE WITH TCEQ RULES AND REGULATIONS, TAC TITLE 30 PART I CHAPTER 217.57. 1/2" ANGLE IRON (9 REQ'D) JI VI_ VI\ I\J( VII_YY T ,.'.,... ►��ic�i�re�r•1�c7:►��•'l1m•x•III IML•]►I SEWER PIPE \IDLE BLOCK OR APPROVED SUBSTITUTE SUPPORT FOR VARIES ENCASEMENT OR CRADLE NOTES: 1) ALL CONCRETE ENCASEMENT SHALE BE POURED AT A PLANE 6" ABOVE THE PIPE BETWEEN EXCAVATED TRENCH WALLS. 2) AL-_.-_ SEWER MAIN WITH 1 -LESS THAN 4' OF COVER TO FINAL GRADE SHALL BE CONCRETE ENCASED. 3) ALL FORCE MAINS SHALL BE PROVIDED WITH THRUST BLOCKS, WHERE CHANCES IN DIRECTION OCCUR, AT TEES, BENDS, CROSSES, CHANGES IN SIZE, STOPS, OR AS DIRECTED BY ENGINEER. 1/2„ 1 " DIA ..,JND OFF CORNERS 01-AUGUST-2016 NOTES: 1. MATERIALS FOR SANITARY SEWER LATERAL SHALL CONFORM TO THE CITY OF SCHERTZ STANDARD SPECIFICATIONS FOR PRIVATE SEWAGE FACILITIES. ALL FLEXIBLE PIPE SHALL CONFORM TO A MINIMUM OF ATSM DESIGNATION D -3034 (SDR -35 OR BETTER) WITH COMPRESSION JOINT GASKETS OR SHALL BE SOLVENT, JOINT. 2. IF THE PROPERTY IS INSIDE SCHERTZ CITY LIMITS, A PERMIT IS REQUIRED FROM THE CITY EXISTING GROUND LEVEL OF SCHERTZ BUILDING AND ZONING PLUMBING SECTION. BEFORE LANDSCAPING OR FILLING IT WITH TOP SOIL 3. DEPTH AND GRADE OF SERVICE LATERALS AS SHOWN, ARE TYPICAL ONLY. ACTUAL DEPTH, ALIGNMENT AND GRADE OF SERVICE LATERALS SHALL BE DETERMINED BY THE ENGINEER SECONDARY BASED ON THE ELEVATIONS OF THE SEWER MAIN, STREET, NATURAL GROUND AND BUILDING BACKFILL TO BE SERVICED. INITIAL BACKFILL - GRAVEL OR 4. A MINIMUM OF 3' OF COVER TO SUBGRADE IS NECESSARY, OTHERWISE CONCRETE CRUSHED STONE ENCASEMENT WILL BE REQUIRED. 3' MIN 12" MIN (1/4" TO 1 3/4" SIZE) MIN. 6" LATERAL LATERAL TO BE IDENTIFIED AT THE PROPERTY LINE �- BEDDING - GRAVEL OR m WITH A -6" METALLIC 6 „ MIN CRUSHED STONE IDENTIFICATION TAPE , (1/4” TO 1 -3/4" SIZE) vn p CURB 0. D. 12" MAX D D " STREET 1. A MINIMUM OF THREE FEET (3') OF COVER OVER THE TOP OF THE LATERAL SHALL BE _ D D o __. D D D _� • d, MAINTAINED, OR THE LATERAL MUST BE: D D D ppD FF((,D,1� yDD��rD D D, D �9 3" MIN. A. ENCASED WITH SIX INCHES (6 ") OF CONCRETE HAVING A MINIMUM COMPRESSION i ­11A, STRENGTH OF 2500 P.S.I. (DETAIL "A "), OR CONCRETE ENCASE LATERAL CONNECTION 1 FOOT EACH SIDE OF LATERAL & 6" ALL AROUND PIPE. INCLUDE IN COST OF LATERAL SEWER MAII COIVIVLV I IVIV / •IVII BENDS (AS REQUIRED) Ww0u_ SEWER MAIN ul • �pPE 4� L HOUSE LATERAL (6" DIA. MIN.) B. INSTEAD OF CONCRETE ENCASEMENT, SLEEVING WITH BIGGER DIAMETER PIPE CAN BE USED FOR THE ENTIRE LENGTH OF LESS THAN THREE FEET (3') IN DEPTH 2% (DETAIL "B "). THE SLEEVING MATERIAL SHALL BE OF THE SAME MATERIAL AS THE LATERAL AND MUST HAVE AT LEAST NINE INCHES ( "9 ") OF COVER MATERIAL TO THE EXISTING GROUND LEVEL. sly-l1 8lifil PRECAST TEE WITH BEND MAY BE USED IN LIEU OF WYE HOUSE LATERAL DETAL LATERAL REDUCING COUPLING STUB -OUT LATERAL SADDLE ACCEPTABLE NOTE: -THE SADDI'_ _ E SHALL BE PERMANENTLY BONDED ..TO THE. EXISTING MAIN BY THF USE OF COMPOUNDS OR CLAMPS AS RECOMMENDED BY THE MANUEACT URFR. STUB -OUT UNACCEPTABLE LATERAL CONNECTION TO EXISTING SEWER MAINy%STUB -OUT z Lo SEE NOTE VARIES PAY LIMITS FOR STACKS NOTE "A" WHERE CROSSFALL EXISTS, ELEVATION OF TOP OF STACKS SHALL BE SHOWN ON PLANS, AS DIRECTED BY THE ENGINEER STACKS SHALL BE REQUIRED WHERE THE TOP OF THE SEWER MAIN IS AT A DEPTH OF EIGHT FEET (8') OR GREATER, HOWEVER, WHERE STACKS ARE REQUIRED, THEY SHALL BE SHOWN ON THE PLANS, AS DIRECTED BY THE ENGINEER, BASED ON ELEVATIONS OF THE SEWER MAIN, STREETS, NATURAL GROUND AND BUILDING TO BE SERVED 2. BEDDING — WHERE ACCCEPTABLE MATERIALS ARE ENCOUNTERED AT THE PIPE BEARING LEVEL, THEY SHALL BE ACCEPTABLE FOR BEDDING PURPOSES. WHERE UNACCEPTABLE MATERIALS, SUCH AS WATER, SILT, MUCK, TRASH, DEBRIS. OR ROCK IN LEDGE OR BOULDER, ARE FOUND AT THE PIPE BEARING LEVEL, OR IF FLEXIBLE PIPE IS USED, THE TRENCH SHOULD BE UNDER EXCAVATED AS DIRECTED AND BACKFILLED WITH CRUSHED STONE OR GRAVEL, 1/4" TO 1-3/4" SIZE. THE EMBEDDING SHALL EXTEND UP THE SIDES OF THE PIPE SUFFICIENTLY TO EMBED THE LOWER QUADRANT OF THE PIPE. �i � i :'� � � � 6 � � i �� • ► � !' ! � Lid i i� u n � �1 1 � � � i • • MIN. SLOPE ���•'� END STACKS WITH CURVE, OR BEND AND PLUG WHERE REQUIRED USE "Y" BRANCH WHEN HOUSE LATERALS ARE REQUIRED ON BOTH SIDES OF SEWER 6" DIA. PEG TO WALL OF TRENCH AT EACH JOINT WITH MIN. STAINLESS STEEL MATERIALS. OMIT "Y" A BRANCH WHEN HOUSE LATERAL IS REQUIRED ON ONLY ONE SIDE OF SEWER a ° ; • a 45° BEND HUB OF TEE G • C• G . ° TEE (AS REQUIRED) 0 CONCRETE ENCASEMENT NO SEPARATE PAY ITEM VERTICAL STACK DETAIL z z i� SECTION A —A NOTE: 01 CONCRETE ENCASEMENT TO BE 2" GREATER THAN THE FULL LENGTH OF TEE !`ITT x T nr n i a BLOCK UP 3" AS NECESSARY 222222 221