Loading...
17-M-48 Reimbursement Agreement with CVS Pharmacy for construction of a water line extensionWHEREAS, a water main needs to be extended from FM 1103 at Old Wiederstein Road to Fairfax Drive to connect to an existing main on Sunridge Drive within the Riata Subdivision. WHEREAS, a water main extension across the frontage of the proposed Schertz Retail Center property is being built in accordance with the City's Unified Development Code. WHEREAS, the water main needs to be extended beyond the frontage of the proposed development in order to loop the water main to alleviate the potential for stagnant water in a dead -end main. WHEREAS, CVS Pharmacy, Inc., as the Developer of the Schertz Retail Center Subdivision, agrees to construct the entire water main extension of which a portion is more than what is required by this development. WHEREAS, the City Council finds that it is in the best interest of the City to enter into the Agreement with Developer for Construction of Public Improvement in order to avoid having a dead -end main. WHEREAS, Section 212.071, et. seq. of the Texas Local Government Code authorizes municipalities to enter into a contract with a developer of a subdivision or land in the municipality to construct public improvements related to the development without complying with the competitive sealed bidding procedures of Chapter 252 of the Texas Local Government Code; and WHEREAS, Section 212.071, et. seq. of the Texas Local Government Code limits the participation by the municipality at a level not to exceed 30 percent of the total contract price. NOW, THEREFORE, BE IT ORDAINED BY THE CITY COUNCIL OF THE CIYT OF SCHERTZ, TEXAS: The City Council hereby authorizes the City Manager to execute the agreement with Developer for Construction of Public Improvement with CVS Pharmacy, Inc., for infrastructure that will alleviate a dead -end main by looping the water main. Section 1. The recitals contained in the preamble hereof are hereby found to be true, and such recitals are hereby made a part of this Ordinance for all purposes and are adopted as a part of the judgment and findings of the City Council. Section 2. That should any section, clause, or provision of this ordinance be declared by a court of competent jurisdiction to be invalid, the same shall not affect the validity of this ordinance or any other ordinance of the City as a whole or any part thereof, other than the part so declared to be invalid. Section 3. That it is officially found, determined and declared that the meeting at which this Ordinance is adopted was open to the public and public notice of the time, place, and subject matter of the public business to be considered at such meeting, including this ordinance, was given, all as required by Chapter 551, as amended, Texas Government Code. Section 4. This Ordinance shall be effective upon the date of final adoption hereof and any publication required by law. Section 5. This Ordinance shall be cumulative of all other ordinances of the City of Schertz, and this Ordinance shall not operate to repeal or affect any other ordinances of the City of chertz except insofar as the provisions thereof might be inconsistent or in conflict with the provisions of this Ordinance, in which event such conflicting provisions, if any, are hereby repealed. i ecretary, Brenda Dennis L Now _2® 902� REIMBURSEMENT AGREEMENT WITH DEVELOPER FOR CONSTRUCTION OF PUBLIC IMPROVEMENT THE STATE OF TEXAS § § KNOW ALL PERSONS BY THESE PRESENTS: COUNTY OF GUADALUPE § This Development Agreement (the "Agreement ") is by and between the City of Schertz, a Texas municipal corporation (the "City"), and CVS Pharmacy, Inc., owner and developer of certain hereinafter described property located within the City (the "Developer "), all collectively referred to as "Parties ", and is effective upon the execution of this Agreement by the Developer and the City (the "Effective Date "). WHEREAS, Developer wishes to develop certain property (the "Property ") located within the City limits, which is approximately 6.850 acres of land situated in the Rafael Garza Survey No. 98, Abstract No. 1.38, in the City of Schertz, Guadalupe County, Texas; being portion of a 2.00 Acre Tract of Land Described in Volume 1474, Page 960, Being that same tract of Land as described as 1.91 Acres in Deed of Trust as recorded in Volume 3172 Page 535 and portion of a 10.0 Acre Tract of Land Described in Volume 1969, Page 269 of the Official Public Records or Guadalupe County, Texas. WHEREAS, the Property is the subject of the application for Subdivision Plat establishing Schertz Retail Center; and WHEREAS, the Property abuts an existing subdivision and ROW wherein all water and sewer infrastructure (collectively the "Improvements ") from the intersection of FM 1.1.03 and Old Wiederstein Road, to Fairfax Road and along Fairfax Road to Sunridge Road have not been completed; and WHEREAS, during the development planning stage for the Property, the Developer submitted to the City a request that the City participate in the completion of the Improvements, which will benefit portions of the City beyond the Schertz Retail. Center Subdivision; and WHEREAS, the City has no immediate plans to construct the required Improvements, but is willing to share in the cost of the construction of such facilities, and has funds appropriated and available to do so; and WHEREAS, Developer has requested that it be allowed to construct the required Improvements to serve the Property, and share the costs with the City; and WHEREAS, Section 212.071, et. seq. of the Texas Local Government Code authorizes municipalities to enter into a contract with a developer of a subdivision or land in the municipality to construct public improvements related to the development without complying with the competitive sealed bidding procedures of Chapter 252 of the Texas Local Government Code; and WHEREAS, Section 212.071, et. seq. of the Texas Local Government Code limits the participation by the municipality at a level not to exceed 30 percent of the total contract price. NOW THEREFORE, for and in consideration of the premises and mutual obligations, covenants, and benefits hereinafter set forth, the Parties agree as follows: ARTICLE I — Definitions. The following terms and phrases used in this Agreement shall have the meanings ascribed hereto: 1.1. "Agreement" means this agreement, including any amendments hereto, between. the City and Developer. 1.2. "Contractor" shall mean the person, firm, corporation, partnership, association, or other entity awarded the contact by Developer for the construction and installation of the Improvements. 1.3. " hmprovements" shall mean the improvements described on Exhibit "A" 1.4. "City's Participation Costs" shall mean costs associated with the construction of the Improvements, as designated on Exhibit `B" as City of Schertz responsibility. ARTICLE II — Construction of Improvements. 2.1. Construction of Improvements. Developer agrees to construct the Improvements in accordance with the plans and specifications approved by the City Engineer as illustrated in Exhibit "A" attached hereto. No change in the construction plans shall be made by Developer without the prior written consent of the City Engineer. The entire cost of the construction of the Improvements shall be the responsibility and obligation of Developer, except as herein provided. 2.2. Contracts for Construction. Developer shall contract with a qualified Contractor to construct the Improvements in accordance with the approved plans and specifications. The City Engineer shall review all contract documents and costs estimates, and shall approve the Contractor prior to the award of the contract for the Improvements. Developer shall be solely responsible for payment of the work as it is completed, and shall make all payments in a timely manner to the Contractor, sub - contractors, and other parties involved in the construction of the Improvements. 2.3. Performance, Payment and Maintenance Bonds. Developer shall post within the City faithful performance, payment, and maintenance bonds for construction of the Improvements to ensure completion of the project. The bond must be executed by a corporate surety in accordance with Chapter 2253, Texas Government Code. 2.4. Inspection. The City Engineer or designee shall periodically inspect the construction of the Improvements in the same manner, and shall possess the same authority, as is provided during the construction of subdivision improvements pursuant to the City of Schertz Subdivision Ordinance, as amended. 2.5. Insurance. The Contractor awarded the contract to construct the Improvements shall be required to carry Worker's Compensation Insurance on his employees and public liability and property damage insurance on his equipment and employees. The public liability insurance shall be not less than five hundred thousand dollars ($500,000.00) per person and one million dollars ($1,000,000.00) per occurrence, with property damage insurance of not less than five hundred thousand dollars ($500,000.00). In addition, City shall be furnished with Certificates of Insurance and shall be named an additional named insured on such Certificates, and City shall be notified within thirty calendar days of any cancellation of such insurance. 2.6. Accounting. Developer shall submit to City a complete accounting of all costs incurred by Developer in the construction of the Improvements. City will not contribute or pay for any costs incurred by Developer which were not approved by City prior to it being incurred. Developer shall maintain the accounting of the Improvements for a period of two years from the date of acceptance by the City, and the City may inspect the Developer's books and records related to the Improvements at any time with reasonable notice. 2.7. Indemnity. Developer agrees to protect, indemnify and save City harmless from and against all claims, demands and causes of action of every kind and character arising in favor of any third party on account of, or resulting from, the performance of this Agreement by Developer or Developer's agents, representatives, employees, contractors, or subcontractors. ARTICLE III — Obligations and Payments. 3. 1. City Obligations. The City agrees to pay to Developer City's Participation Costs which shall equate to the actual costs for the City's responsibility at as illustrated on Exhibit "A". Notwithstanding any provision of this Agreement to contrary, City's Obligation shall only b e for the reimbursement of costs incurred by Developer and shall not in any event exceed Seventy-Seven Thousand Eight Hundred Ninety-Seven Dollars and Fifty-Seven Cents ($77,897.57) (hereinafter the "City's Share"). 3.2. Payment Procedures. City shall deliver to Developer full payment of the City's Share as provided in this this section. 3.2.1 Submittal and review. Developer shall submit and the City Engineer shall review documentation, as may be reasonably required by City Engineer, showing final, actual construction costs paid by the Developer. 3.2.2 Upon the City Engineer's review and approval of the documents, a final inspection on the Improvements shall be conducted, noting any required corrections or repairs. Once corrections or repairs are made and deemed acceptable, the City will accept the Improvements. 3.2.3 Within 30 days of acceptance of the Improvements, the City will pay to Developer the City's Share. Any additional costs above Seventy- Seven. Thousand Eight Hundred Ninety -Seven Dollars and Fifty -Seven Cents ($77,897.57) must be approved by the City prior to being incurred. Article IV — Assignment, Modification and Waiver. 4.1. Assignment. This Agreement shall bind and benefit the respective Parties and their legal successors and shall not be assignable, in whole or in party, by any party without first obtaining written consent of the other party. 4.2. Amendment or Modification. Except as otherwise provided in this Agreement, this Agreement shall be subject to change, amendment or modification only in writing, and by the signatures and mutual consent of the Parties. 4.3. Parties in Interest. This Agreement shall be for the sole and exclusive benefit of the Parties hereto and shall not be construed to confer any rights upon any third party. 4.4. Remedies Not Exclusive. The rights and remedies contained in this Agreement shall not be exclusive, but shall be cumulative of all rights and remedies now or hereinafter existing, by law or in equity. 4.5. Waiver. The failure of any party to insist in any one or more instances on the performance of any of the terms, covenants or conditions of this Agreement, or to exercise any of its rights, shall not be construed as a waiver or relinquishment of such term, covenant, or condition, or right with respect to further performance. 4.6. Entire Agreement. This Agreement constitutes the entire agreement between the Parties related to the subject matter of this Agreement and supersedes any and all prior agreements, whether oral or written, dealing with the subject matter of this Agreement. 4.7. Venue. This Agreement shall be performable and enforceable in Guadalupe County, Texas, and shall be construed in accordance with the laws of the State of Texas. 4.8. Severability. If any term or provision of this Agreement is held to be invalid, void or unenforceable by a court of competent jurisdiction, the remainder of the terms and provisions of this Agreement shall remain in full force and effect and shall not in any way be invalidated, impaired or affected. 4.9. Notices. Any notice provided or permitted to be given under this Agreement must be in writing and may be served by (i) depositing the same in the United States mail, addressed to the party to be notified, postage prepaid, registered or certified mail, return receipt requested; or (ii) by delivering the same in person to such party; or (iii) by overnight or messenger delivery service that retains regular records of delivery and receipt; or (iv) by facsimile; provided a copy of such notice is sent within one (l) day thereafter by another method provided above. The initial addresses of the parties for the purpose of notice under this Agreement shall be as follows: If to City: CITY OF SCHERTZ 1400 Schertz Parkway Schertz, TX 78154 Attention: City Manager With copy to: Denton Navarro Rocha Bernal & Zech, P.C. 2417 N. Main Avenue San Antonio, TX 78212 Attention: Charles Zech If to Developer: CVS Pharmacy Inc. 1 CVS Drive, Woonsocket, RI 02895 4.10. No Joint Venture. Nothing contained in this Agreement is intended by the Parties to create a partnership or joint venture between the Parties and any implication to the contrary is hereby expressly disavowed. It is understood and agreed that this Agreement does not create a joint enterprise, nor does it appoint either Party as an agent of the other for any purpose whatsoever. Except, as otherwise specifically provided herein, neither Party shall in any way assume any of the liability of the other for acts of the other or obligations of the other. 4.11. Counterparts. This Agreement may be executed in multiple counterparts, each of which shall be considered an original, but all of which constitute one instrument. [Signatures and acknowledgments on the following pages-] Signature Page to Agreement with Developer for Construction of Public Improvement This Agreement has been executed by the parties as of the dates of the Acknowledgments to be effective as of the Effective Date. Developer: CVS PHARMACY, INC. by: Name: Kimberly A. Shardlow Title: Assistant Secretary THE STATE OF COUNTY OF This instrument was acknowledged before me on the day of , 2017 by Kimberly A. Shardlow, Assistant Secretary for CVS Pharmacy Inc,., for the purposes herein expressed. (SEAL) Notary Public in and for The State of Texas My Commission Expires: Signature Page to Agreement with Developer for Construction of Public Improvement This Community Facilities Agreement has been executed by the parties as of the dates of the Acknowledgments to be effective as of the Effective Date. City: CITY OF SCHERTZ, a Texas municipal corporation By: Name: John C. Kessel, its City Manager THE STATE OF TEXAS COUNTY OF GUADALUPE This instrument was acknowledged before me on the day of , 2017 by John C. Kessel, City Manager of the City of Schertz, Texas, a Texas municipal corporation, on behalf of said City. (SEAL) Notary Public in and for The State of Texas My Commission Expires: EXHIBIT A IMPROVEMENTS EXHIBIT B CITY'S PARTICIPATION COSTS UTILITY NOTES: 1) GUADALUPE VALLEY ELECTRIC COOPERATIVE, INC. WILL PROVIDE UNDERGROUND ELECTRICAL SERVICE FROM THE EXISTING SERVICE POLE TO THE TRANSFORMER PAD. CONTRACTOR MUST PROVIDE TWO 5" PVC (SCH 80) CONDUITS AND A PULL STRING FROM THE EXISTING ELECTRICAL SERVICE POLE TO THE PROPOSED TRANSFORMER LOCATION. THE CONTRACTOR IS ALSO RESPONSIBLE FOR INSTALLING THREE 5" PVC CONDUITS AND SECONDARY WIRING FROM THE TRANSFORMER PAD TO THE PROPOSED BUILDING. THE CONTRACTOR IS RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH THE POWER SERVICE INSTALLATION AND SHALL COORDINATE WITH THE POWER COMPANY FOR FINAL UNDERGROUND CONDUIT LOCATIONS. 2) CENTERPOINT ENERGY WILL PERFORM THE GAS SERVICE CONNECTION, INSTALL THE CONDUIT, AND SET THE METER FOR THE BUILDING. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING THE SERVICE FROM THE METER INTO THE PROPOSED BUILDING. THE CONTRACTOR MUST COORDINATE WITH CENTERPOINT ENERGY. 3) CONTRACTOR MUST PROVIDE AND INSTALL A 3" PVC CONDUIT WITH PULL STRING, FROM THE EXISTING TELEPHONE SERVICE POLE TO THE TELEPHONE BOARD IN THE BUILDING. THE CONTRACTOR MUST ALSO PROVIDE A #6 GROUND WIRE AT THE TELEPHONE BOARD FOR THE TELEPHONE COMPANY TO INSTALL A PHONE LINE. 4) CITY OF SCHERTZ WILL FURNISH THE DOMESTIC WATER METER, HOWEVER THE CONTRACTOR WILL BE REQUIRED TO FURNISH ALL EQUIPMENT AND PERFORM THE TAP AND INSTALLATION. THE CONTRACTOR MUST PROVIDE AND INSTALL THE METER BOX, DOUBLE CHECK BACKFLOW PREVENTER AND ENCLOSURE, AND THE WATER SERVICE LINE FROM THE WATER METER TO THE BUILDING. 5) CITY OF SCHERTZ WILL FURNISH THE IRRIGATION METER, HOWEVER THE CONTRACTOR WILL BE REQUIRED TO FURNISH ALL EQUIPMENT AND PERFORM THE TAP AND INSTALLATION.. THE CONTRACTOR MUST PROVIDE AND INSTALL THE METER BOX, DOUBLE CHECK BACKFLOW PREVENTER AND ENCLOSURE, AND THE IRRIGATION LINES TO THE AREAS SPECIFIED ON THIS SHEET AND ON SHEET 1 -1. 6) CONTRACTOR SHALL COORDINATE AS REQUIRED WITH CITY OF SCHERTZ INSPECTIONS DURING CONSTRUCTION FOR REQUIRED INSPECTIONS. 7) THIS SITE INDICATES POTABLE WATER SERVICE AND SANITARY SEWER LATERALS. THIS WORK TO BE INSTALLED BY A LICENSED PLUMBER IF STATE LAW REQUIRES. ALL WORK MUST BE INSPECTED BY CITY OF SCHERTZ CODES AND INSPECTION DEPARTMENT. 8) ALL ON -SITE PVC PIPE SHALL HAVE CLASS B BEDDING. 9) ALL CONDUIT, PIPE, AND CHASE PIPE SHALL BE WRAPPED WITH THE APPROPRIATE LOCATION WIRE AND TAPE. 10) NO PRESSURE REDUCING VALVES ARE TO BE INSTALLED ON FIRE LINES. ALL FIRE LINES ARE TO BE INSPECTED BY CITY OF SCHERTZ FIRE SERVICE PRIOR TO COVERING. 11) NOTIFY WATER AND SEWER INSPECTOR PRIOR TO START OF CONSTRUCTION. 12) CONTRACTOR SHALL PROVIDE A COMPLETE SET OF AS -BUILT DRAWINGS INCLUDING ALL RIM ELEVATIONS, INVERT ELEVATIONS, PIPE SIZES, AND PIPE MATERIAL FOR ALL PUBLIC MAINS TO THE ENGINEER AS SOON AS INSTALLATION IS COMPLETE. 13) OWNER SHALL BE RESPONSIBLE FOR ANY REPAIR OR REPLACEMENT OF ANY IMPROVEMENTS WITHIN THE SANITARY SEWER, WATER, DRAINAGE EASEMENT(S) DUE TO MAINTENANCE OF SEWER, WATER, STORM DRAIN OF CITY OF SCHERTZ. 14) CONTRACTOR SHALL INSTALL THE DOWNSTREAM SANITARY SEWER CONNECTION IN THE RIGHT OF WAY PRIOR TO THE INSTALLATION OF THE ON -SITE SERVICE LATERALS. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING UTILITIES SHOWN ON THE PLANS BY POT HOLING THE LINES. THE CONTRACTOR SHALL HAVE THE LINES SURVEYED, INCLUDING HORIZONTAL AND VERTICAL LOCATION, AND THE SURVEYED POINTS SENT TO THE PROJECT ENGINEER TO DETERMINE IF ANY UTILITY CONFLICTS WILL AFFECT THE CURRENT SANITARY SEWER DESIGN. 15) PVC WATER LINES LESS THAN 3" SHALL BE ASTM D 2241, SDR 21 WITH INTEGRALLY MOLDED BELL ENDS, ASTM D 2672. PVC WATER LINES 3" AND LARGER SHALL BE AWWA C900, RATED DR 18 (CLASS 150) WITH INTEGRALLY MOLDED BELL ENDS, ASTM D3139. DIP WATER LINES SHALL BE AWWA C151, THICKNESS CLASS 50. 16) PVC SANITARY SEWER LINES SHALL BE ASTM D 3034, RATED SDR 35 WITH INTEGRALLY MOLDED BELL ENDS, ASTM D 3034, TABLE 2, WITH FACTORY SUPPLIED ELECTROMETRIC GASKETS AND LUBRICANT. DIP SANITARY SEWER LINES SHALL BE ASTM A746, CLASS 50 WITH AWWA C111, RUBBER GASKET JOINT DEVICES. 17) DEMOLISHED UTILITIES NOT DEPICTED ON THIS SHEET. REFER TO THE DEMOLITION PLAN. 18) CONTRACTOR TO SAWCUT ANY SIDEWALK OR PAVEMENT THAT IS TO BE REMOVED FOR UTILITY INSTALLATION. CONTRACTOR IS RESPONSIBLE FOR REPLACING SIDEWALK, PAVEMENT AND EXISTING INFRASTRUCTURE THAT IS REMOVED /ALTERED DURING INSTALLATION OF WATER LINE. CONTRACTOR TO MATCH EXISTING CONDITION OF SIDEWALK AND PAVEMENT. 19) THE CONTRACTOR MUST FOLLOW AND ABIDE BY STANDARD NOTES AND REQUIREMENTS PROVIDED IN THE STANDARD DETAILS FOR THE CITY OF SCHERTZ PUBLIC WORKS. PLEASE REFER TO THE DETAIL SHEETS WITHIN THE DEVELOPMENT SET FOR DETAILS. SCHERTZ RETAIL CENTER EXHIBIT A iPS ♦ / t / I / r � / t \ \ \\ PROPOSED 30' >. UTILITY EASEMENT \ V A PROPOSED 6" SANITARY SEWER V A LATERAL FOR FUTURE \ EXISTING 95' DEVELOPMENT TIE IN \ V A UTILITYEASEMENT WATER CONNECTION DETAIL CONTRACTOR TO \ (2) 12" VALVES BUILT INTO EACH INSTALL WATER TEE GATE VALVE AND PLUG FOR FUTURE CONNECTION -'" / CONTRACTOR TO REMOVE $!� EXISTING BEND AND INSTALL 12" X 12" X 12" LATERAL TEE a 20 LF 12" C900 PVC WATER LINE CONTRACTOR TO 12" X 12" X 12" WATER TEE STUB 12" WATER MAIN FOR FUTURE CONNECTION 3 LF 12" C900 PVC WATER LINE 146.25 DEGREE WATER BEND 12" INLINE VALVE 81 107 LF 12" C900 PVC WATER LINE PROPOSED 16' WATER EASEMENT � I � I i N ` o NcA_ Knowwhat'sbelow Call before you dig V- 206 LF OF 12" C900 PVC WATER LINE 12" INLINE VALVE ♦ �— PROPOSED FIRE HYDRANT ASSEMBLY "i (CONTRACTOR TO REFER TO CITY OF SCHERTZ FIRE HYDRANT ASSEMBLY s DETAIL) 302 LF OF 12" C900 PVC WATER LINE EXISTING WA TER MAIN CONTRACTOR TO MAINTAIN A MINIMUM HORIZONTAL SEPARATION OF 4' FROM THE EXISTING MAIN TO THE PROPOSED MAIN. CONTRACTOR TO FOLLOW CITY OF SCHERTZ PAVED AREA TRENCH DETAIL FOR WATER MAIN INSTALLATION (TRENCH TO BE 6' WIDE CENTERED ON MAIN INSTALL, TOFF FACE OF CURB) CONTRACTOR TO COORDINATE WITH CITY OF SCHERTZ INSPECTOR FOR FLOWABLE FILL AREAS (REFER TO DETAIL C -7) APPROXIMA TE LOCA TION OF SANITARYFORCE MAIN SEE WATER CONNECTION DETAIL INSERT y' 115 LF OF 12" C900 PVC WATER LINE CONTRACTOR TO REMOVE PORTION OF CONCRETE RIPRAP FOR WATER MAIN INSTALLATION. CONTRACTOR TO SAWCUT AT EXTENTS OF TRENCH AND REMOVE AND REPLACE WITH SAME CONCRETE THICKNESS) PROPOSED FIRE HYDRANT ASSEMBLY (CONTRACTOR TO REFER TO CITY OF SCHERTZ FIRE HYDRANT ASSEMBLY DETAIL) rCVS pharmacy TM 14,698-LEFT i ■i ►I ■O ENGINEER: FORE Foresite Group, Inc. 1999 Bryan St. Suite 890 Dallas, TX 75201 CONSULTANT: REVISIONS: CITY COMMENTS 03/20/2017 CITY COMMENTS 03/30/2017 CITY COMMENTS 04/04/2017 CITY COMMENTS 04/06/2017 CITY COMMENTS 04/10/2017 CITY COMMENTS 4/17/2017 CITY COMMENTS 4/18/2017 CITY COMMENTS 4/19/2017 DRAWING BY: DK DATE: 02/24/2017 JOB NUMBER: 164.079 TITLE: UTILITIES PLAN SHEET NUMBER: C�3. COMMENTS: NOT RELEASED FOR CONSTRUCTION LEGEND EXISTING FENCE LINE PROPERTY LINE EXISTING UNDERGROUND COMMUNICATION LINE 0HP 0HP 11)HP EXISTING OVERHEAD POWER LINE — w — IN EXISTING WATER LINE EXISTING STORM LINE CATV CATV PROPOSED CABLE TELEVISION LINE — FOC FOC FOC — PROPOSED FIBER OPTIC LINE —OHP OHP OHP— PROPOSED OVERHEAD POWER LINE UG(E UGIE PROPOSED UNDERGROUND POWER LINE uGIT UGrr PROPOSED UNDERGROUND TELEPHONE LINE — GAS GAS GAS — PROPOSED GAS LINE — SS SS SS — PROPOSED SANITARY SEWER LINE —w w w— PROPOSED WATER LINE —Fw Fw Fw— PROPOSED FIRE WATER LINE ..__ _... PROPOSED STORM LINE PROPOSED UTILITY TRENCH AND PAVEMENT SCHERTZ RETAIL CENTER EXHIBIT A iPS ♦ / t / I / r � / t \ \ \\ PROPOSED 30' >. UTILITY EASEMENT \ V A PROPOSED 6" SANITARY SEWER V A LATERAL FOR FUTURE \ EXISTING 95' DEVELOPMENT TIE IN \ V A UTILITYEASEMENT WATER CONNECTION DETAIL CONTRACTOR TO \ (2) 12" VALVES BUILT INTO EACH INSTALL WATER TEE GATE VALVE AND PLUG FOR FUTURE CONNECTION -'" / CONTRACTOR TO REMOVE $!� EXISTING BEND AND INSTALL 12" X 12" X 12" LATERAL TEE a 20 LF 12" C900 PVC WATER LINE CONTRACTOR TO 12" X 12" X 12" WATER TEE STUB 12" WATER MAIN FOR FUTURE CONNECTION 3 LF 12" C900 PVC WATER LINE 146.25 DEGREE WATER BEND 12" INLINE VALVE 81 107 LF 12" C900 PVC WATER LINE PROPOSED 16' WATER EASEMENT � I � I i N ` o NcA_ Knowwhat'sbelow Call before you dig V- 206 LF OF 12" C900 PVC WATER LINE 12" INLINE VALVE ♦ �— PROPOSED FIRE HYDRANT ASSEMBLY "i (CONTRACTOR TO REFER TO CITY OF SCHERTZ FIRE HYDRANT ASSEMBLY s DETAIL) 302 LF OF 12" C900 PVC WATER LINE EXISTING WA TER MAIN CONTRACTOR TO MAINTAIN A MINIMUM HORIZONTAL SEPARATION OF 4' FROM THE EXISTING MAIN TO THE PROPOSED MAIN. CONTRACTOR TO FOLLOW CITY OF SCHERTZ PAVED AREA TRENCH DETAIL FOR WATER MAIN INSTALLATION (TRENCH TO BE 6' WIDE CENTERED ON MAIN INSTALL, TOFF FACE OF CURB) CONTRACTOR TO COORDINATE WITH CITY OF SCHERTZ INSPECTOR FOR FLOWABLE FILL AREAS (REFER TO DETAIL C -7) APPROXIMA TE LOCA TION OF SANITARYFORCE MAIN SEE WATER CONNECTION DETAIL INSERT y' 115 LF OF 12" C900 PVC WATER LINE CONTRACTOR TO REMOVE PORTION OF CONCRETE RIPRAP FOR WATER MAIN INSTALLATION. CONTRACTOR TO SAWCUT AT EXTENTS OF TRENCH AND REMOVE AND REPLACE WITH SAME CONCRETE THICKNESS) PROPOSED FIRE HYDRANT ASSEMBLY (CONTRACTOR TO REFER TO CITY OF SCHERTZ FIRE HYDRANT ASSEMBLY DETAIL) rCVS pharmacy TM 14,698-LEFT i ■i ►I ■O ENGINEER: FORE Foresite Group, Inc. 1999 Bryan St. Suite 890 Dallas, TX 75201 CONSULTANT: REVISIONS: CITY COMMENTS 03/20/2017 CITY COMMENTS 03/30/2017 CITY COMMENTS 04/04/2017 CITY COMMENTS 04/06/2017 CITY COMMENTS 04/10/2017 CITY COMMENTS 4/17/2017 CITY COMMENTS 4/18/2017 CITY COMMENTS 4/19/2017 DRAWING BY: DK DATE: 02/24/2017 JOB NUMBER: 164.079 TITLE: UTILITIES PLAN SHEET NUMBER: C�3. COMMENTS: NOT RELEASED FOR CONSTRUCTION UTILITY NOTES: 1) GUADALUPE VALLEY ELECTRIC COOPERATIVE, INC. WILL PROVIDE UNDERGROUND ELECTRICAL SERVICE FROM THE EXISTING SERVICE POLE TO THE TRANSFORMER PAD. CONTRACTOR MUST PROVIDE TWO 5" PVC (SCH 80) CONDUITS AND A PULL STRING FROM THE EXISTING ELECTRICAL SERVICE POLE TO THE PROPOSED TRANSFORMER LOCATION. THE CONTRACTOR IS ALSO RESPONSIBLE FOR INSTALLING THREE 5" PVC CONDUITS AND SECONDARY WIRING FROM THE TRANSFORMER PAD TO THE PROPOSED BUILDING. THE CONTRACTOR IS RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH THE POWER SERVICE INSTALLATION AND SHALL COORDINATE WITH THE POWER COMPANY FOR FINAL UNDERGROUND CONDUIT LOCATIONS. 2) CENTERPOINT ENERGY WILL PERFORM THE GAS SERVICE CONNECTION, INSTALL THE CONDUIT, AND SET THE METER FOR THE BUILDING. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING THE SERVICE FROM THE METER INTO THE PROPOSED BUILDING. THE CONTRACTOR MUST COORDINATE WITH CENTERPOINT ENERGY. 3) CONTRACTOR MUST PROVIDE AND INSTALL A 3" PVC CONDUIT WITH PULL STRING, FROM THE EXISTING TELEPHONE SERVICE POLE TO THE TELEPHONE BOARD IN THE BUILDING. THE CONTRACTOR MUST ALSO PROVIDE A #6 GROUND WIRE AT THE TELEPHONE BOARD FOR THE TELEPHONE COMPANY TO INSTALL A PHONE LINE. 4) CITY OF SCHERTZ WILL FURNISH THE DOMESTIC WATER METER, HOWEVER THE CONTRACTOR WILL BE REQUIRED TO FURNISH ALL EQUIPMENT AND PERFORM THE TAP AND INSTALLATION. THE CONTRACTOR MUST PROVIDE AND INSTALL THE METER BOX, DOUBLE CHECK BACKFLOW PREVENTER AND ENCLOSURE, AND THE WATER SERVICE LINE FROM THE WATER METER TO THE BUILDING. 5) CITY OF SCHERTZ WILL FURNISH THE IRRIGATION METER, HOWEVER THE CONTRACTOR WILL BE REQUIRED TO FURNISH ALL EQUIPMENT AND PERFORM THE TAP AND INSTALLATION.. THE CONTRACTOR MUST PROVIDE AND INSTALL THE METER BOX, DOUBLE CHECK BACKFLOW PREVENTER AND ENCLOSURE, AND THE IRRIGATION LINES TO THE AREAS SPECIFIED ON THIS SHEET AND ON SHEET 1 -1. 6) CONTRACTOR SHALL COORDINATE AS REQUIRED WITH CITY OF SCHERTZ INSPECTIONS DURING CONSTRUCTION FOR REQUIRED INSPECTIONS. 7) THIS SITE INDICATES POTABLE WATER SERVICE AND SANITARY SEWER LATERALS. THIS WORK TO BE INSTALLED BY A LICENSED PLUMBER IF STATE LAW REQUIRES. ALL WORK MUST BE INSPECTED BY CITY OF SCHERTZ CODES AND INSPECTION DEPARTMENT. 8) ALL ON -SITE PVC PIPE SHALL HAVE CLASS B BEDDING. 9) ALL CONDUIT, PIPE, AND CHASE PIPE SHALL BE WRAPPED WITH THE APPROPRIATE LOCATION WIRE AND TAPE. 10) NO PRESSURE REDUCING VALVES ARE TO BE INSTALLED ON FIRE LINES. ALL FIRE LINES ARE TO BE INSPECTED BY CITY OF SCHERTZ FIRE SERVICE PRIOR TO COVERING. 11) NOTIFY WATER AND SEWER INSPECTOR PRIOR TO START OF CONSTRUCTION. 12) CONTRACTOR SHALL PROVIDE A COMPLETE SET OF AS -BUILT DRAWINGS INCLUDING ALL RIM ELEVATIONS, INVERT ELEVATIONS, PIPE SIZES, AND PIPE MATERIAL FOR ALL PUBLIC MAINS TO THE ENGINEER AS SOON AS INSTALLATION IS COMPLETE. 13) OWNER SHALL BE RESPONSIBLE FOR ANY REPAIR OR REPLACEMENT OF ANY IMPROVEMENTS WITHIN THE SANITARY SEWER, WATER, DRAINAGE EASEMENT(S) DUE TO MAINTENANCE OF SEWER, WATER, STORM DRAIN OF CITY OF SCHERTZ. 14) CONTRACTOR SHALL INSTALL THE DOWNSTREAM SANITARY SEWER CONNECTION IN THE RIGHT OF WAY PRIOR TO THE INSTALLATION OF THE ON -SITE SERVICE LATERALS. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING UTILITIES SHOWN ON THE PLANS BY POT HOLING THE LINES. THE CONTRACTOR SHALL HAVE THE LINES SURVEYED, INCLUDING HORIZONTAL AND VERTICAL LOCATION, AND THE SURVEYED POINTS SENT TO THE PROJECT ENGINEER TO DETERMINE IF ANY UTILITY CONFLICTS WILL AFFECT THE CURRENT SANITARY SEWER DESIGN. 15) PVC WATER LINES LESS THAN 3" SHALL BE ASTM D 2241, SDR 21 WITH INTEGRALLY MOLDED BELL ENDS, ASTM D 2672. PVC WATER LINES 3" AND LARGER SHALL BE AWWA C900, RATED DR 18 (CLASS 150) WITH INTEGRALLY MOLDED BELL ENDS, ASTM D3139. DIP WATER LINES SHALL BE AWWA C151, THICKNESS CLASS 50. 16) PVC SANITARY SEWER LINES SHALL BE ASTM D 3034, RATED SDR 35 WITH INTEGRALLY MOLDED BELL ENDS, ASTM D 3034, TABLE 2, WITH FACTORY SUPPLIED ELECTROMETRIC GASKETS AND LUBRICANT. DIP SANITARY SEWER LINES SHALL BE ASTM A746, CLASS 50 WITH AWWA C111, RUBBER GASKET JOINT DEVICES. 17) DEMOLISHED UTILITIES NOT DEPICTED ON THIS SHEET. REFER TO THE DEMOLITION PLAN. 18) CONTRACTOR TO SAWCUT ANY SIDEWALK OR PAVEMENT THAT IS TO BE REMOVED FOR UTILITY INSTALLATION. CONTRACTOR IS RESPONSIBLE FOR REPLACING SIDEWALK, PAVEMENT AND EXISTING INFRASTRUCTURE THAT IS REMOVED /ALTERED DURING INSTALLATION OF WATER LINE. CONTRACTOR TO MATCH EXISTING CONDITION OF SIDEWALK AND PAVEMENT. 19) THE CONTRACTOR MUST FOLLOW AND ABIDE BY STANDARD NOTES AND REQUIREMENTS PROVIDED IN THE STANDARD DETAILS FOR THE CITY OF SCHERTZ PUBLIC WORKS. PLEASE REFER TO THE DETAIL SHEETS WITHIN THE DEVELOPMENT SET FOR DETAILS. SCHERTZ RETAIL CENTER EXHIBIT A /PS LEGEND EXISTING FENCE LINE PROPERTY LINE EXISTING UNDERGROUND COMMUNICATION LINE \E'P 0HP Dip EXISTING OVERHEAD POWER LINE v EXISTING WATER LINE „.. EXISTING STORM LINE CATV CATV PROPOSED CABLE TELEVISION LINE —FOC FOC FOC— PROPOSED FIBER OPTIC LINE -OHP OHP OHP— PROPOSED OVERHEAD POWER LINE uGie uGie PROPOSED UNDERGROUND POWER LINE uG(r u0 /T PROPOSED UNDERGROUND TELEPHONE LINE —GAS GAS GAS— PROPOSED GAS LINE — SS SS SS — PROPOSED SANITARY SEWER LINE —w w w— PROPOSED WATER LINE —Fw Fw Fw— PROPOSED FIRE WATER LINE PROPOSED STORM LINE PROPOSED UTILITY TRENCH AND PAVEMENT SCHERTZ RETAIL CENTER EXHIBIT A /PS \c / t � \ \ \ \ \ O \ \ \ . 1 ...v . 61 `\ q \ , v\ y�{ 400 / $ t , - PROPOSED 12" INLINE VALVE SGHtK I Z PAVEU AREA I HENGH DETAIL FOR WATER MAIN yz�;,..tt. # ' INSTALLATION (TRENCH TO BE 6' _�'-- 8" X 8" X 8" CUT IN WATER TEE WIDE CENTERED ON MAIN INSTALL, V — (2) 8" VALVES BUILT INTO WATER TEE 3' OFF FACE OF CURB) " — CONTRACTOR TO OPEN CUT ROADWAY FOR WATER MAIN EXTENSION ' l� „ UTILITY EXHIBIT Developer Responsibility - Wastewater Developer Responsibility -Water City Responsibility - Water 37 LF LF OF 8" C900 PVC WATER LINE i 12" X 8" WATER REDUCER 7 f 89 LF LF OF 12" C900 PVC WATER LINE - t "A� APPROX/MA TEL 0CAT/ON OF SANITARY SEWER MANHOLE APPROX/MA TEL OCAT /ON OF ` 18" SANITARY SEWER GRAV/TYMA /N EXISTING RIGHT -OF -WAY LINE i" p P` CONTRACTOR TO MAINTAIN A MINIMUM HORIZONTAL y7z -" SEPARATION OF 4' FROM THE EXISTING MAIN TO THE r -" PROPOSED MAIN. --� 290 LF OF 12" C900 PVC WATER LINE EXISTING GROUND MOUNTED ` TRANSFORMER (CONTRACTOR TO COORDINATE WITH GVEC DURING CONSTRUCTION TO MAINTAIN POWER SERVICE) PROPOSED FIRE HYDRANT (REFER TO CITY OF SCHERTZ FIRE HYDRANT ASSEMBLY 45 DEGREE WATER BEND DETAIL) — THRUST BLOCK (TYP.) %VCVS pharmacy TM 14,698-LEFT DIVIVE-TUVU BU, ►lPO ENGINEER: FORES11TE Foresite Group, Inc. 1999 Bryan St. Suite 890 Dallas, TX 75201 CONSULTANT: o 214.939.7123 f 888.765.8135 w ( www.fg- inc.net REVISIONS: CITY COMMENTS 03/20/2017 CITY COMMENTS 03/30/2017 CITY COMMENTS 04/04/2017 CITY COMMENTS 04/06/2017 CITY COMMENTS 04/10/2017 CITY COMMENTS 4/18/2017 CITY COMMENTS 4/19/2017 DRAWING BY: DK DATE: 02/24/2017 JOB NUMBER: 164.079 TITLE: UTILITIES PLAN SHEET NUMBER: C�3 ■ 1_ COMMENTS: NOT RELEASED FOR CONSTRUCTION i' \c / t � \ \ \ \ \ O \ \ \ . 1 ...v . 61 `\ q \ , v\ y�{ 400 / $ t , - PROPOSED 12" INLINE VALVE SGHtK I Z PAVEU AREA I HENGH DETAIL FOR WATER MAIN yz�;,..tt. # ' INSTALLATION (TRENCH TO BE 6' _�'-- 8" X 8" X 8" CUT IN WATER TEE WIDE CENTERED ON MAIN INSTALL, V — (2) 8" VALVES BUILT INTO WATER TEE 3' OFF FACE OF CURB) " — CONTRACTOR TO OPEN CUT ROADWAY FOR WATER MAIN EXTENSION ' l� „ UTILITY EXHIBIT Developer Responsibility - Wastewater Developer Responsibility -Water City Responsibility - Water 37 LF LF OF 8" C900 PVC WATER LINE i 12" X 8" WATER REDUCER 7 f 89 LF LF OF 12" C900 PVC WATER LINE - t "A� APPROX/MA TEL 0CAT/ON OF SANITARY SEWER MANHOLE APPROX/MA TEL OCAT /ON OF ` 18" SANITARY SEWER GRAV/TYMA /N EXISTING RIGHT -OF -WAY LINE i" p P` CONTRACTOR TO MAINTAIN A MINIMUM HORIZONTAL y7z -" SEPARATION OF 4' FROM THE EXISTING MAIN TO THE r -" PROPOSED MAIN. --� 290 LF OF 12" C900 PVC WATER LINE EXISTING GROUND MOUNTED ` TRANSFORMER (CONTRACTOR TO COORDINATE WITH GVEC DURING CONSTRUCTION TO MAINTAIN POWER SERVICE) PROPOSED FIRE HYDRANT (REFER TO CITY OF SCHERTZ FIRE HYDRANT ASSEMBLY 45 DEGREE WATER BEND DETAIL) — THRUST BLOCK (TYP.) %VCVS pharmacy TM 14,698-LEFT DIVIVE-TUVU BU, ►lPO ENGINEER: FORES11TE Foresite Group, Inc. 1999 Bryan St. Suite 890 Dallas, TX 75201 CONSULTANT: o 214.939.7123 f 888.765.8135 w ( www.fg- inc.net REVISIONS: CITY COMMENTS 03/20/2017 CITY COMMENTS 03/30/2017 CITY COMMENTS 04/04/2017 CITY COMMENTS 04/06/2017 CITY COMMENTS 04/10/2017 CITY COMMENTS 4/18/2017 CITY COMMENTS 4/19/2017 DRAWING BY: DK DATE: 02/24/2017 JOB NUMBER: 164.079 TITLE: UTILITIES PLAN SHEET NUMBER: C�3 ■ 1_ COMMENTS: NOT RELEASED FOR CONSTRUCTION EXHIBIT B SCHERTZ RETAIL CENTER WATER AND WASTEWATER EXTENSION COST Description Cost Quantity Unit Unit Cost Unit E manhole over existing stub $ 7,758.70 1 $ 7,758.70 LUMP 8 SDR 26 PCV Pipe $23,241.55 423 LF $ 54.94 LF 8 "x6" single clean out w Traffic Cover $ 2,263.50 1 $ 2,263.50 LUMP 5' Manholes with 32" Ring and Covers $ 28,878.80 4 $ 7,219.70 EACH 5' Risers $17,838.60 6 $ 2,973.10 EACH Road Bores with Pits $35,084.45 1 $ 35,084.45 LUMP 18 Casing $9,458.20 131 LF $ 72.20 LF 18" Ca sing Spacers and Seals $3,244.50 7 $ 463.50 EACH Detectable Warning Tape $ 167.75 1 $ 167.75 EACH Trench Excavation Protection $1,677.50 1 $ 1,677.50 LUMP Spoil Removal $ 2,200.00 1 $ 2,200.00 LUMP Manhole Testing $ 1,254.00 1 $ 1,254.00 LUMP Air Test $ 544.50 1 $ 544.50 LUMP Subtotal Offsite Sewer $ 133,612.05 12" MJ Cut In Tee with MegaLug $ 5,117.75 1 EACH $ 5,117.75 EACH 8" Ml Cut In Tee with Megalug $ 4,557.55 1 EACH $ 4,557.55 EACH 12" Ml Gate Valve with Box 1 EACH $14,694.30 8 EACH $ 1,836.79 EACH 8" Ml Gate Valve with Box $ 3,098.10 2 EACH $ 1,549.05 EACH 12" C -900 Dr -14 PVC Pipe $ 46,413.20 1220 LF $ 38.04 LF 8" C -900 Dr-14 PVC Pipe $ 598.00 37 LF $ 16.16 LF 6" PR 350 Ductile Iron Pipe $ 2,047.65 52 LF $ 39.38 LF MJ 1/32" deg Bend w Megalug $ 1,291.90 1 EACH $ 1,291.90 EACH MJ 1/16" deg Bend w Mega $ 660.90 1 EACH $ 660.90 EACH M11/8" deg Bend w Megalug $ 2,02120 3 EACH $ 674.40 EACH 12x6 MJ Anchor Tee $ 2,947.20 4 EACH $ 736.80 EACH 12 Ml Tee w Mega Lug $ 887.46 1 EACH $ 887.46 EACH 12x8 MJ Reducer w MegaLug $ 558.80 1 EACH $ 558.80 EACH 12" Vertical Offset $ 2,337.60 2 EACH $ 1,168.80 EACH 12x2 Temp Blow off $ 1,577.65 1 EACH $ 1,577.65 EACH 4 Std Hydrant Assy Complete $ 17,789.60 4 EACH $ 4,447.40 EACH 3000 PSI thrust block $ 4,033.80 5 EACH $ 806.76 EACH Detectable warning tape $ 312.25 2 EACH $ 156.13 EACH Hydrostatic Pressure Test $ 560.20 1 LUMP $ 560.20 LUMP Spoils Removal $ 4,950.00 1 LUMP $ 4,950.00 LUMP 2" asphalt repair $ 11,157.80 577 SQ. YD. $ 19.34 SQ. YD. Traffic Control $ 13,200.00 1 LUMP $ 13,200.00 LUMP Steel Plates $ 2,750.00 1 LUMP $ 2,750.00 LUMP 290 cu yds flowable Fill $ 38,280.00 290 Cu Yds $ 132.00 Cu Yds 2" adjust existing fire hydrant $ 1,244.90 1 EACH $ 1,244.90 EACH 2" demo existing meter at Tap $ 24930 1 EACH $ 249.90 EACH All costs by Five star (subdivided by Tenants) Schertz Retail Center Costs (To be split among tenants) City of Schertz Costs Cost Schertz Quantity Schertz Unit Unit Cost Unit $ - 0 EACH $ 5,117.75 EACH $ 4,557.55 1 EACH $ 4,557.55 EACH $ 1,836.79 1 EACH $ 1,836.79 EACH $ 3,098.10 2 EACH $ 1,549.05 EACH $20,315.29 534 LF $ 38.04 LF $ 598.00 37 LF $ 16.16 LF $ 1,023.83 26 LF $ 39.38 LF $ 1,29130 1 EACH $ 1,291.90 EACH $ - 0 EACH $ 660.90 EACH $ 1,348.80 2 EACH $ 674.40 EACH $ 1,473.60 2 EACH $ 736.80 EACH $ - EACH $ 887.46 EACH $ 558.80 1 EACH $ 558.80 EACH $ - 0 EACH $ 1,168.80 EACH $ - 0 EACH $ 1,577.65 EACH $ 8,894.80 2 EACH $ 4,447.40 EACH $ 2,420.28 3 EACH $ 806.76 EACH $ 156.13 1 EACH $ 156.13 EACH $ - 0 LUMP $ 560.20 LUMP $ - 0 LUMP $ 4,950.00 LUMP $ 4,737.71 245 SQ. YD. $ 19.34 SQ. YD. $ 6,600.00 0.5 LUMP $ 13,200.00 LUMP $ 2,750.00 1 LUMP $ 2,750.00 LUMP $16,236.00 123 Cu Yds $ 132.00 Cu Yds $ - 0 EACH $ 1,244.90 EACH $ - 0 EACH $ 249.90 EACH Schertz Retail Center Costs (To be split among tenants) Cost Five Star Quantity Five Star Unit Unit Cost Unit $ 5,117.75 1 EACH $ 5,117.75 EACH $ - 0 EACH $ 4,557.55 EACH $ 12,857.51 7 EACH $ 1,836.79 EACH $ - 0 EACH $ 1,549.05 EACH $ 26,097.91 686 LF $ 38.04 LF $ - 0 LF $ 16.16 LF $ 1,023.83 26 LF $ 39.38 LF $ - 0 EACH $ 1,29130 EACH $ 660.90 1 EACH $ 660.90 EACH $ 674.40 1 EACH $ 674.40 EACH $ 1,473.60 2 EACH $ 736.80 EACH $ 887.46 1 EACH $ 887.46 EACH $ - 0 EACH $ 558.80 EACH $ 2,337.60 2 EACH $ 1,168.80 EACH $ 1,577.65 1 EACH $ 1,577.65 EACH $ 8,894.80 2 EACH $ 4,447.40 EACH $ 1,613.52 2 EACH $ 806.76 EACH $ 156.13 1 EACH $ 156.13 EACH $ 560.20 1 LUMP $ 560.20 LUMP $ 4,950.00 1 LUMP $ 4,950.00 LUMP $ 6,420.09 332 SQ. YD. $ 19.34 SQ. YD. $ 6,600.00 0.5 LUMP $ 13,200.00 LUMP $ - 0 LUMP $ 2,750.00 LUMP $ 22,044.00 167 Cu Yds $ 132.00 Cu Yds $ 1,244.90 1 EACH $ 1,244.90 EACH $ 249.90 1 EACH $ 249.90 EACH Offsite Water Subtotal $ 183,339.71 $77,897.57 $105,442.14