Loading...
HGV Investments Unit 2, Lot 1, Blk 2 Approved Site Plan 10-13-20 [SP]6'' W T R 6'' W T R 6'' WTR 1. 5 ' ' W T R 1. 5 ' ' W T R 1.5'' WTR x x x x x x x x x x x x x x x x x x xxxxxxxxxxxxxxxxx LOT 1, BLOCK 1 HGV INVESTMENTS UNIT-1 Doc. No. 201006000609 LAND USE: COMMERCIAL ZONED: M-1 REMAINDER OF CALLED 85.469 ACRES HGV INVESTMENTS, L.L.C. Doc. No. 200906010500 LAND USE: VACANT ZONED:M-1 LOT 1, BLOCK 1 CLOSNER-FM 2252 SUBDIVISION M-1 ZONING Vol. 15, Pg. 266, PRCCT CALLED 0.95 ACRE TIMOTHY G. KING KELLEY C. KING M-1 ZONING Doc. No. 201606037642 CALLED 0.94 ACRE TIMOTHY G. KING KELLEY C. KING M-1 ZONING Doc. No. 201506027307 CALLED 10.001 ACRES UFP WESTERN DIVISION, INC. Doc. No. 201106003599 UFP SCHERTZ SUBDIVISION M-1 ZONING CONSTRUCTION MATERIAL SALES CALLED 13.009 ACRES UNIVERSAL FOREST PRODUCTS TEXAS LIMITED PARTNERSHIP Doc. No. 9806028976 UFP SCHERTZ SUBDIVISION M-1 ZONING CONSTRUCTION MATERIAL SALES CALLED 15.00 ACRES TRACT 2 BELTWAY INVESTMENTS, INC. Doc. No. 9606025555 CALLED 19.350 ACRES TIFFANY BRICK CO., L.P. Vol. 984, Pg. 650 F.M. 2252 (R.O.W. VARIES) (ASPHALT SURFACE) VOL. 94, PG. 298 12'' WTR12'' WTR12'' WTR12'' WTR12'' WTR12'' WTR12'' WTR12'' WTR12'' WTR LOT 1 12.503 ACRES FIRM PANEL 48091C0420F EFFECTIVE SEPTEMBER 2, 2009 ZONE AE PER LOMR 09063497P EFFECTIVE AUGUST 13, 2010 LOT 2 BLDG. #1 4,266 SQ FT SHOWROOM / OFFICE SPACE FFE=746.65 BLDG. #2 5,546 SQ FT MATERIAL STORAGE FFE=745.37 SC A L E 50 ' J O I N T A C C E S S E A S E M E N T 60 ' S C H E R T Z W W E S M T 50' SCHERTZ WW ESMT 14' E.G.T. & T.V. EASEMENT 20' GVSUD ESMT VOL.____/ PG._____ 29.2' TXDOT ROW DEDICATION 20' SCHERTZ WW ESMT 14' E.G.T. & T.V. EASEMENT 20' GVSUD ESMT VOL.____/ PG._____ 96 . 0 0 ' 14 3 . 0 0 ' 5. 0 0 ' 14 0 . 5 0 ' 10.00' 10.00' TYP 51.00'74.00' 120.00' 12R @ 10' 6R @ 10' - 1HC (7 SPACES TOTAL) 5R @ 10' 47.00' 5. 0 0 ' R24 . 5 0 ' R 2 4 . 5 0 ' 35. 0 0 ' 35.00' 3 5 . 0 0 ' 25. 0 0 ' 15. 0 0 ' 22 1 . 2 5 ' 221 . 2 5 ' 15. 0 0 '25. 0 0 ' 20 . 0 0 ' T Y P 31 . 0 0 ' 45.00' 195.82'560.19'210.77'234.00' 20.00' 194.90' 190.92' 31 . 0 0 ' ADA CURB RAMP AND SIGNAGE ASPHALT DRIVEWAY NO PARKING - FIRE ZONE NO PARKING - FIRE ZONE DETENTION POND 64.00'45.33' R2 4 . 5 0 ' R24.50' 61.00' 12.05' 4. 6 2 ' R24.5 0 ' ASPHALT DRIVEWAY 21.95' 180.06' 173.35' 28 1 . 4 3 ' 72 . 5 4 ' 24 9 . 2 8 ' 95 . 7 6 ' R55 . 5 0 ' R 2 4 . 5 0 ' 31.00' 35 . 0 0 ' PALLETIZED MATERIAL STORAGE PALLETIZED MATERIAL STORAGE 15' x 15' x 7' TALL - DUMPSTER ENCLOSURE ON 15' x 15' x 6" THICK REINFORCE CONCRETE PAD (SEE DETAIL) SEPTIC SYSTEM (BY OTHERS) 73 5 740 745 750 730 73 5 73 5 73 1 73 273 2 73 3 73 3 73 4 73 4 73 5 73 2 733 73 4 73 6 73 7 73 8 SEE OUTLET STRUCTURE DETAIL SHEET 12 R3 9 . 5 0 ' R 3 9 . 5 0 ' R1 9 9 . 5 0 ' R1 9 9 . 5 0 ' 640.58' R39.5 0 ' R39 . 5 0 ' R39 . 5 0 ' R66 . 5 0 ' SIDEWALK TO BE BUILT WHEN LOT 2 IS DEVELOPED BULK MATERIAL STORAGE (THESE ARE NOT PARKING SPACE) BULK MATERIAL STORAGE (THESE ARE NOT PARKING SPACE) LOADING DOCK (THIS IS NOT A PARKING SPACE) LOADING DOCK (THIS IS NOT A PARKING SPACE) 20 . 0 0 ' T Y P 20 . 0 0 ' T Y P 10 . 0 0 ' T Y P 10 . 0 0 ' T Y P FLOOD PLAIN FLOOD PLAIN FLOOD PLAIN SIDEWALK TO BE BUILT WITH THIS PROJECT 6' TALL SCREEN WALL - 6" CMU BLOCK WITH STONE VENEER SEE DETAIL #5 ON SHEET 136' TALL SCREEN WALL - 6" CMU BLOCK WITH STONE VENEER SEE DETAIL #5 ON SHEET 13 0 60'120' SCALE: 1" = 60' Project No. Sheet No. Drawn By: Check by: Date: PR E P A R E D FO R : No . DA T E BY DE S C R I P T I O N THOMAS J. GROLL 90976 ◊ 5 2 0 8 P R Y O R L A N E , AU S T I N , T E X A S 7 8 7 3 4 ◊ (5 1 2 ) 848 - 57 9 6 ◊ TB P E F I R M # F - 9 7 9 9 ◊ ◊ W W W . T G - E N G . C O M ◊ FP H A C I E N D A P R O P E R T I E S , L L C BO X 7 0 6 JA R R E L L , T X 7 6 5 3 7 MBS TJG HG V I N V E S T M E N T S U N I T 2 , L O T 1 , B L O C K 1 CO B R A S T O N E R E T A I L O U T L E T 21 7 9 9 F M 2 2 5 2 SC H E R T Z , T X 7 8 1 5 4 N ---- 7 of 18 9/22/2020 SI T E P L A N PROPOSED CURB & GUTTER LEGEND PAINTED CURB ACCESSIBLE ROUTE SIDEWALK "NO PARKING - FIRE ZONE" HANDICAP RAMP LEGEND LANDSCAPE AREA REGULAR PARKING STALLS2R @ X' HANDICAP PARKING STALLS2HC @ X' PROPERTY LINE SINGLE POLE WITH SINGLE LED FIXTURE DOUBLE POLE WITH DOUBLE LED FIXTURE DIMENSIONAL SITE PLAN NOTES 1.PER 21.9.8 B(4)SCREENING OF TRASH RECEPTACLES. ALL TRASH RECEPTACLES SHALL BE SCREENED FROM PUBLIC VIEW BY A SOLID SCREENING WALL A MINIMUM OF EIGHT FEET (8') IN HEIGHT AND CONSTRUCTED OF A MASONRY MATERIAL. GATES SHALL BE OF SOLID METAL AND SHALL BE CLOSED AT ALL TIMES EXCEPT WHEN LOADING AND UNLOADING. 2.ALL WALLS 30" OR HIGHER THAN FINAL GRADE AND ALONG PEDESTRIAN OR VEHICULAR ROUTES MAY NEED HANDRAIL. CONTRACTOR TO COORDINATE HANDRAIL LOCATIONS WITH OWNER AND ENGINEER DURING CONSTRUCTION. 3.ALL DIMENSIONS ARE REFERENCED TO BACK OF CURB, OR TO EDGE OF GRAVEL DRIVEWAY WHERE CURB IS NOT PLANNED. 4.ALL DRIVING SURFACES SHALL BE ABLE TO BE ENGINEERED TO WITHSTAND 75,000 LBS. 2012 IFC 503 AND D102.1 MARKED PEDESTRIAN CROSSING PROJECT INFORMATION: COBRA STONE - SCHERTZ OWNER: FP HACIENDA PROPERTIES, LLC 297 LOGAN RANCH ROAD GEORGETOWN, TX 78628 CONTACT:PEDRO AGUADO PHONE;(512) 746-5600 EMAIL:pedro@cobrastone.com OWNER'S AGENT:THOMAS J. GROLL, P.E. TOM GROLL ENGINEERING, PC 5208 PRYOR LANE AUSTIN, TX 78734 FIRM #9799 SITE ADDRESS:21799 FM 2252 SCHERTZ, TX 78154 LEGAL DESC:20.503 ACRES CALVIN P. ABBOTT SURVEY ABSTRACT 262 COMAL COUNTY, TEXAS RECORDING INFO:DEED DOC. #201706009249 ZONING:M-1 (MANUFACTURING - LIGHT) SUBDIVISION:HACIENDA SUBDIVISION EXISTING USE:VACANT PROPOSED USE:COMMERCIAL (BUILDING MATERIALS SALES) FLOODPLAIN:ACCORDING TO FIRM PANEL 48091C0420F DATED SEPTEMBER 2, 2009 - 0.420 AC. IS LOCATED IN ZONE 'AE' PER LOMR DATED AUGUST 13, 2010 AND 12.084 AC. OF THIS SITE IS LOCATED IN ZONE X AND IS NOT WITHIN THE 100-YEAR FLOODPLAIN. IMPERVIOUS COVER: DRIVEWAYS/PARKING/MATERIAL STORAGE = 269,192 ft2 BUILDINGS = 9,812 ft2 SIDEWALKS = 1,960 ft2 TOTAL IMPERVIOUS COVER = 280,964 ft2 SITE AREA = 544,668 ft2 % IMPERVIOUS COVER = 51.58% PROPOSED BUILDING AREA:OFFICE/SHOWROOM = 4,266 ft2 STORAGE = 5,546 ft2 BUILDING HEIGHT:33' - 10” (MATERIALS STORAGE BLDG.) 23' - 4” (OFFICE/STORAGE BLDG.) 25' - 0” (CANOPY) PARKING RATIOS:1 SPACE/1,000 ft2/ FOR STORAGE BUILDING = 6 SPACES 1 SPACE/250 ft2/ FOR OFFICE BUILDING = 18 SPACES 1 VAN ACCESSIBLE SPACE REQUIRED PARKING PROVIDED:23 REGULAR 1 VAN ACCESSIBLE 24 TOTAL PARKING SPACES FLOOR AREA:9,812 ft2 LOT 1 AREA:544,668 ft2 (12.503 AC) FLOOR/AREA RATIO:0.018 THE AREA OF LOT 1 IS 12.503 ACRES (544,668 ft2) BLDG. #1 4,266 SQ FT SHOWROOM / OFFICE SPACE FFE=746.65 BLDG. #2 5,546 SQ FT MATERIAL STORAGE FFE=745.37 SC A L E 50 ' J O I N T A C C E S S E A S E M E N T 60 ' S C H E R T Z W W E S M T 50' SCHERTZ WW ESMT 14' E.G.T. & T.V. EASEMENT 20' GVSUD ESMT VOL.____/ PG._____ 29.2' TXDOT ROW DEDICATION 20' SCHERTZ WW ESMT 14' E.G.T. & T.V. EASEMENT 20' GVSUD ESMT VOL.____/ PG._____ x x x x x x x x x x x x x x x x x x xxxxxxxxxxxxxxxxx F.M. 2252 (R.O.W. VARIES) (ASPHALT SURFACE) VOL. 94, PG. 298 12'' WTR12'' WTR12'' WTR12'' WTR12'' WTR12'' WTR12'' WTR12'' WTR12'' WTR FIRM PANEL 48091C0420F EFFECTIVE SEPTEMBER 2, 2009 ZONE AE PER LOMR 09063497P EFFECTIVE AUGUST 13, 2010 ASPHALT DRIVEWAY DETENTION POND ASPHALT DRIVEWAY 6'' W T R 6'' W T R 6'' WTR 1. 5 ' ' W T R 1. 5 ' ' W T R 1.5'' WTR PALLETIZED MATERIAL STORAGE PALLETIZED MATERIAL STORAGE BULK MATERIAL STORAGE BULK MATERIAL STORAGE LANDSCAPE 0 60'120' SCALE: 1" = 60' Project No. Sheet No. Drawn By: Check by: Date: PR E P A R E D FO R : No . DA T E BY DE S C R I P T I O N THOMAS J. GROLL 90976 ◊ 5 2 0 8 P R Y O R L A N E , AU S T I N , T E X A S 7 8 7 3 4 ◊ (5 1 2 ) 848 - 57 9 6 ◊ TB P E F I R M # F - 9 7 9 9 ◊ ◊ W W W . T G - E N G . C O M ◊ FP H A C I E N D A P R O P E R T I E S , L L C BO X 7 0 6 JA R R E L L , T X 7 6 5 3 7 MBS TJG HG V I N V E S T M E N T S U N I T 2 , L O T 1 , B L O C K 1 CO B R A S T O N E R E T A I L O U T L E T 21 7 9 9 F M 2 2 5 2 SC H E R T Z , T X 7 8 1 5 4 N ---- 8 of 18 9/22/2020 SI T E L A N D U S E P L A N PROPOSED CURB & GUTTER LEGEND PAINTED CURB ACCESSIBLE ROUTE SIDEWALK "NO PARKING - FIRE ZONE" HANDICAP RAMP LEGEND LANDSCAPE AREA PROPERTY LINE SINGLE POLE WITH SINGLE LED FIXTURE DOUBLE POLE WITH DOUBLE LED FIXTURE MARKED PEDESTRIAN CROSSING ASPHALT / DRIVEWAY / FIRE LANE PARKING PALLETIZED MATERIAL STORAGE CRUSHED GRAVEL DRIVEWAY BULK MATERIAL STORAGE x x x x x x x x x x x x x x x x x x xxxxxxxxxxxxxxxxx LOT 1, BLOCK 1 HGV INVESTMENTS UNIT-1 Doc. No. 201006000609 LAND USE: COMMERCIAL ZONED: M-1 REMAINDER OF CALLED 85.469 ACRES HGV INVESTMENTS, L.L.C. Doc. No. 200906010500 LAND USE: VACANT ZONED:M-1 LOT 1, BLOCK 1 CLOSNER-FM 2252 SUBDIVISION M-1 ZONING Vol. 15, Pg. 266, PRCCT CALLED 0.95 ACRE TIMOTHY G. KING KELLEY C. KING M-1 ZONING Doc. No. 201606037642 CALLED 0.94 ACRE TIMOTHY G. KING KELLEY C. KING M-1 ZONING Doc. No. 201506027307 CALLED 10.001 ACRES UFP WESTERN DIVISION, INC. Doc. No. 201106003599 UFP SCHERTZ SUBDIVISION M-1 ZONING CONSTRUCTION MATERIAL SALES CALLED 13.009 ACRES UNIVERSAL FOREST PRODUCTS TEXAS LIMITED PARTNERSHIP Doc. No. 9806028976 UFP SCHERTZ SUBDIVISION M-1 ZONING CONSTRUCTION MATERIAL SALES CALLED 15.00 ACRES TRACT 2 BELTWAY INVESTMENTS, INC. Doc. No. 9606025555 CALLED 19.350 ACRES TIFFANY BRICK CO., L.P. Vol. 984, Pg. 650 F.M. 2252 (R.O.W. VARIES) (ASPHALT SURFACE) VOL. 94, PG. 298 12'' WTR12'' WTR12'' WTR12'' WTR12'' WTR12'' WTR12'' WTR12'' WTR12'' WTR LOT 1 12.503 ACRES FIRM PANEL 48091C0420F EFFECTIVE SEPTEMBER 2, 2009 ZONE AE PER LOMR 09063497P EFFECTIVE AUGUST 13, 2010 LOT 2 HP T C T C TC T C T C T C T C T C T C T C T C TC TC T C T C TC TC T C T C T C TC TC T C T C T C TC T C T C T C TC T C T C T C TC TC TC TC TC TC TC TC TC T C TC TC T C TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC SF = 1 5 0 L F @ - 3 . 1 % SCF = 545 LF @ -3.4% SC F = 9 0 0 L F @ - 0 . 7 % SF = 2 2 5 L F @ - 4 . 2 % SC F = 1 , 3 5 0 L F @ 1 . 1 7 % SCF = 1,35 0 L F @ 1 . 1 7 % S C F = 1 , 3 5 0 L F @ 1 . 1 7 % 73 5 73 5 74 0 745 750 755 760 73 2 73 2 73 3 733 73 4 734 73 6 736 737 738 73 9 74 1 742 743 7 4 4 746 747 748 749 751 752 753 754 756 757 758 759 761762 73 5 74 0 7 4 5 7 5 0 75 5 76 0 7 6 0 73 0 73 0 73 0 730 735 EX-1 10.57 AC EX-2 12.35 AC 0 60'120' SCALE: 1" = 60' Project No. Sheet No. Drawn By: Check by: Date: PR E P A R E D FO R : No . DA T E BY DE S C R I P T I O N THOMAS J. GROLL 90976 ◊ 5 2 0 8 P R Y O R L A N E , AU S T I N , T E X A S 7 8 7 3 4 ◊ (5 1 2 ) 848 - 57 9 6 ◊ TB P E F I R M # F - 9 7 9 9 ◊ ◊ W W W . T G - E N G . C O M ◊ FP H A C I E N D A P R O P E R T I E S , L L C BO X 7 0 6 JA R R E L L , T X 7 6 5 3 7 MBS TJG HG V I N V E S T M E N T S U N I T 2 , L O T 1 , B L O C K 1 CO B R A S T O N E R E T A I L O U T L E T 21 7 9 9 F M 2 2 5 2 SC H E R T Z , T X 7 8 1 5 4 N LEGEND PROPERTY BOUNDARY EXISTING CONTOUR THE LOCATION OF EXISTING UNDERGROUND AND OVERHEAD UTILITIES ARE SHOWN IN AN APPROXIMATE WAY ONLY. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK. HE AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT BE OCCASIONED BY HIS FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UNDERGROUND AND OVERHEAD UTILITIES. DRAINAGE DIVIDE TOC FLOWPATHTC DISCHARGE POINT DRAINAGE AREA CALLOUT EX DA5 8.39 AC ---- 5 of 18 9/22/2020 EX I S T I N G D R A I N A G E M A P x x x x x x x x x x x x x x x x x x xxxxxxxxxxxxxxxxx LOT 1, BLOCK 1 HGV INVESTMENTS UNIT-1 Doc. No. 201006000609 LAND USE: COMMERCIAL ZONED: M-1 REMAINDER OF CALLED 85.469 ACRES HGV INVESTMENTS, L.L.C. Doc. No. 200906010500 LAND USE: VACANT ZONED:M-1 LOT 1, BLOCK 1 CLOSNER-FM 2252 SUBDIVISION M-1 ZONING Vol. 15, Pg. 266, PRCCT CALLED 0.95 ACRE TIMOTHY G. KING KELLEY C. KING M-1 ZONING Doc. No. 201606037642 CALLED 0.94 ACRE TIMOTHY G. KING KELLEY C. KING M-1 ZONING Doc. No. 201506027307 CALLED 10.001 ACRES UFP WESTERN DIVISION, INC. Doc. No. 201106003599 UFP SCHERTZ SUBDIVISION M-1 ZONING CONSTRUCTION MATERIAL SALES CALLED 13.009 ACRES UNIVERSAL FOREST PRODUCTS TEXAS LIMITED PARTNERSHIP Doc. No. 9806028976 UFP SCHERTZ SUBDIVISION M-1 ZONING CONSTRUCTION MATERIAL SALES CALLED 15.00 ACRES TRACT 2 BELTWAY INVESTMENTS, INC. Doc. No. 9606025555 CALLED 19.350 ACRES TIFFANY BRICK CO., L.P. Vol. 984, Pg. 650 F.M. 2252 (R.O.W. VARIES) (ASPHALT SURFACE) VOL. 94, PG. 298 12'' WTR12'' WTR12'' WTR12'' WTR12'' WTR12'' WTR12'' WTR12'' WTR12'' WTR LOT 1 12.503 ACRES FIRM PANEL 48091C0420F EFFECTIVE SEPTEMBER 2, 2009 ZONE AE PER LOMR 09063497P EFFECTIVE AUGUST 13, 2010 LOT 2 HP LP TCTCTCTCTCTCTCTCTCTCTCTCTCTCTCTCTCTCTCTCTCTCTCTCTCTCTCTCTC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC T C TC TC TC TC TC TC TC TC TC TC TC TC T C TC TC TC TC TC T C T C TC TC TC TC T C T C TC TC TC TC T C T C TC TC TC TC TC T C TC TC TC TC TC T C TC TC TC TC TC TC TC TC TC TC TCTCTCTC TC TC TC TC TCTCTCTCTCTCTC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC TC SF = 100 LF @ -3.8% SF = 1 5 0 L F @ - 3 . 2 % SCF = 440 LF @ -3.3% SC F = 9 6 0 L F @ - 0 . 8 % SCF = 320 LF @ -3.5% SC F = 5 9 0 L F @ - 0 . 8 % SF = 2 2 5 L F @ - 4 . 2 % S C F = 1 , 3 5 0 L F @ 1 . 1 7 % BLDG. #1 4,266 SQ FT SHOWROOM / OFFICE SPACE FFE=746.65 BLDG. #2 5,546 SQ FT MATERIAL STORAGE FFE=745.37 SC A L E 50 ' J O I N T A C C E S S E A S E M E N T 60 ' S C H E R T Z W W E S M T 50' SCHERTZ WW ESMT 14' E.G.T. & T.V. EASEMENT 20' GVSUD ESMT VOL.____/ PG._____ 29.2' TXDOT ROW DEDICATION 20' SCHERTZ WW ESMT 14' E.G.T. & T.V. EASEMENT 20' GVSUD ESMT VOL.____/ PG._____ 7 3 0 7 3 0 735 73 5 74 0 7 4 5 75 0 755 730 73 5 74 0 7 4 5 7 5 0 7 5 5 76 0 73 5 74 0 74 5 75 0 735 73 5 73 5 740 745 750 6'' W T R 6'' W T R 6'' WTR 1. 5 ' ' W T R 1. 5 ' ' W T R 1.5'' WTR PROPOSED CHANNEL SEE SHEET#3 FOR DETAILS POND BOTTOM @ 1.0% SLOPE WITH 5-FT WIDE TRICKLE CHANNEL PER DETAIL ON SHEET# 11 . PROPOSED EARTH BERM DEV-1 11.04 AC DEV-2 8.95 AC OFF-1 2.92 AC 0 60'120' SCALE: 1" = 60' Project No. Sheet No. Drawn By: Check by: Date: PR E P A R E D FO R : No . DA T E BY DE S C R I P T I O N THOMAS J. GROLL 90976 ◊ 5 2 0 8 P R Y O R L A N E , AU S T I N , T E X A S 7 8 7 3 4 ◊ (5 1 2 ) 848 - 57 9 6 ◊ TB P E F I R M # F - 9 7 9 9 ◊ ◊ W W W . T G - E N G . C O M ◊ FP H A C I E N D A P R O P E R T I E S , L L C BO X 7 0 6 JA R R E L L , T X 7 6 5 3 7 MBS TJG HG V I N V E S T M E N T S U N I T 2 , L O T 1 , B L O C K 1 CO B R A S T O N E R E T A I L O U T L E T 21 7 9 9 F M 2 2 5 2 SC H E R T Z , T X 7 8 1 5 4 N LEGEND PROPERTY BOUNDARY EXISTING CONTOUR THE LOCATION OF EXISTING UNDERGROUND AND OVERHEAD UTILITIES ARE SHOWN IN AN APPROXIMATE WAY ONLY. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK. HE AGREES TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT BE OCCASIONED BY HIS FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL UNDERGROUND AND OVERHEAD UTILITIES. DRAINAGE DIVIDE TOC FLOWPATHTC DISCHARGE POINT DRAINAGE AREA CALLOUTDEV-1 8.39 AC ---- 6 of 18 9/22/2020 PR O P O S E D D R A I N A G E M A P FLOW ARROWS BLDG. #1 4,266 SQ FT SHOWROOM / OFFICE SPACE FFE=746.65 BLDG. #2 5,546 SQ FT MATERIAL STORAGE FFE=745.37 SC A L E 50 ' J O I N T A C C E S S E A S E M E N T 60 ' S C H E R T Z W W E S M T 50' SCHERTZ WW ESMT 14' E.G.T. & T.V. EASEMENT 20' GVSUD ESMT VOL.____/ PG._____ 29.2' TXDOT ROW DEDICATION 20' SCHERTZ WW ESMT 14' E.G.T. & T.V. EASEMENT 20' GVSUD ESMT VOL.____/ PG._____ x x x x x x x x x x x x x x x x x x xxxxxxxxxxxxxxxxx LOT 1, BLOCK 1 HGV INVESTMENTS UNIT-1 Doc. No. 201006000609 LAND USE: COMMERCIAL ZONED: M-1 REMAINDER OF CALLED 85.469 ACRES HGV INVESTMENTS, L.L.C. Doc. No. 200906010500 LAND USE: VACANT ZONED:M-1 LOT 1, BLOCK 1 CLOSNER-FM 2252 SUBDIVISION M-1 ZONING Vol. 15, Pg. 266, PRCCT CALLED 0.95 ACRE TIMOTHY G. KING KELLEY C. KING M-1 ZONING Doc. No. 201606037642 CALLED 0.94 ACRE TIMOTHY G. KING KELLEY C. KING M-1 ZONING Doc. No. 201506027307 CALLED 10.001 ACRES UFP WESTERN DIVISION, INC. Doc. No. 201106003599 UFP SCHERTZ SUBDIVISION M-1 ZONING CONSTRUCTION MATERIAL SALES CALLED 13.009 ACRES UNIVERSAL FOREST PRODUCTS TEXAS LIMITED PARTNERSHIP Doc. No. 9806028976 UFP SCHERTZ SUBDIVISION M-1 ZONING CONSTRUCTION MATERIAL SALES CALLED 15.00 ACRES TRACT 2 BELTWAY INVESTMENTS, INC. Doc. No. 9606025555 CALLED 19.350 ACRES TIFFANY BRICK CO., L.P. Vol. 984, Pg. 650 F.M. 2252 (R.O.W. VARIES) (ASPHALT SURFACE) VOL. 94, PG. 298 12'' WTR12'' WTR12'' WTR12'' WTR12'' WTR12'' WTR12'' WTR12'' WTR12'' WTR LOT 1 12.503 ACRES FIRM PANEL 48091C0420F EFFECTIVE SEPTEMBER 2, 2009 ZONE AE PER LOMR 09063497P EFFECTIVE AUGUST 13, 2010 LOT 2 6'' W T R 6'' W T R 6'' WTR 1. 5 ' ' W T R 1. 5 ' ' W T R 1.5'' WTR74 0 74 5 75 0 755 74 5 745 740 73 5 73 2 7 4 5 742 743 74 4 747 735 740 745 73 0 7 3 0 730 735 735 73 5 7 4 0 7 4 5 75 0 755 760 7 3 0 735 7 3 5 740 745 750 755 7 3 1 732 733 735 73 5 73 2 730 73 7 73 6 739 73 8 73 7 73 5 73 6 73 4 75 0 76 0 760 END 112" WATER LINE SEE MEP PLANS FOR CONTINUATION SEPTIC SYSTEM BY OTHERS 1 - 2 WAY CLEAN OUT 1 - STUB CONNECTION TO BLDG. SEE MEP PLANS 514" F.H. & LEAD PIPE1-6"X6" TEE 1-6" GATE VALVE 1-6"X112" REDUCER 112" TEE WITH 2 - 112"GATE VALVES 1-6"X6" TEE 2-6" GATE VALVES 1-6" STUB FOR FUTURE TIE FIRELINE TO EXISTING 6" SERVICE STUB ON 16" WL EXISTING 12" WL END 112" WATER LINESEE MEP PLANS FOR CONTINUATION INSTALL DOMESTIC METER ASSEMBLY (SIZE PER MEP) INSTALL IRRIGATION METER ASSEMBLY AND 2" BACKFLOW PREVENTER ASSEMBLY INSTALL 6" DCDA BFP ASSEMBLY 0 60'120' SCALE: 1" = 60' Project No. Sheet No. Drawn By: Check by: Date: PR E P A R E D FO R : No . DA T E BY DE S C R I P T I O N THOMAS J. GROLL 90976 ◊ 5 2 0 8 P R Y O R L A N E , AU S T I N , T E X A S 7 8 7 3 4 ◊ (5 1 2 ) 848 - 57 9 6 ◊ TB P E F I R M # F - 9 7 9 9 ◊ ◊ W W W . T G - E N G . C O M ◊ FP H A C I E N D A P R O P E R T I E S , L L C BO X 7 0 6 JA R R E L L , T X 7 6 5 3 7 MBS TJG HG V I N V E S T M E N T S U N I T 2 , L O T 1 , B L O C K 1 CO B R A S T O N E R E T A I L O U T L E T 21 7 9 9 F M 2 2 5 2 SC H E R T Z , T X 7 8 1 5 4 N ---- 10 of 18 9/22/2020 UT I L I T Y P L A N NOTE: CONTRACTOR SHALL LOCATE ALL EXISTING UTILITIES, BOTH HORIZONTALLY AND VERTICALLY, PRIOR TO BEGINNING ANY OTHER WORK. CONTRACTOR SHALL NOTIFY ENGINEER IMMEDIATELY OF ANY DISCREPANCY BETWEEN THE PLANS AND EXISTING UTILITIES IN THE FIELD. CONTRACTOR IS SOLELY RESPONSIBLE FOR ANY RE-WORK REQUIRED AS A RESULT OF SUCH DISCREPANCY UNLESS ENGINEER IS NOTIFIED PRIOR TO BEGINNING ANY OTHER WORK. CONTRACTOR IS RESPONSIBLE FOR ANY/ALL DAMAGE TO EXISTING UTILITIES, APPURTENANCES, SIGNAGE, FLATWORK, ETC. CAUSED BY THE CONSTRUCTION OF THIS PROJECT. LOCATION OF EXISTING UNDERGROUND AND OVERHEAD UTILITIES ARE APPROXIMATE LACATIONS ONLY. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF ALL EXISTING UTILITIES PRIOR TO BEGINNING WORK AND SHALL BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES WHICH MIGHT OCCUR. EASEMENT PROPERTY BOUNDARY RIGHT OF WAY PROPOSED WATER LINEWTR EASEMENT PROPOSED WASTEWATER LINEWW PROPOSED STORM LINE 4" SCHEDULE 40 PVC FOR FUTURE IRRIGATION EXISTING CONTOUR PROPOSED CONTOUR500 504 WASTEWATER FLOW ARROW PROPOSED WASTEWATER MANHOLE 5 14" FIRE HYDRANT W/ 6" GATE VALVE UTILITY PLAN NOTES 1.ALL FIRE DEPARTMENT ACCESS LANES SHALL BE DESIGNED TO WITHSTAND 75,000 LBS LOADING PER THE 2012 IFC 503 AND D102.1 17 of 18Sheet No. 18 of 18Sheet No. 14 of 18 Sheet No. 15 of 18 Sheet No. 9' - 6 " 9' - 6 " 9' - 6 " 16 of 18 Sheet No.