Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Big League 4 Car Wash17969 IH 35 N
PROPOSED BUILDING FF ELEV 833.00' 5,317 SF EXIT ONLY EXIT ONLY © 2024 Microsoft Corporation © 2023 Maxar ©CNES (2023) Distribution Airbus DS SITE PLAN SHEET C.P.E. LOCATOR TELEPHONE LOCATOR TRENCH EXCAVATION SAFETY PROTECTION © NO DATE ISSUES AND REVISIONS BIG LEAGUE CAR WASH #4 GARDEN COMMERCIAL SUBDIVISION LOT 3, BLOCK 1 17969 N I35, SCHERTZ, TX OF 16 BIG LEAGUE CAR WASH 422 FM 306 NEW BRAUNFELS, TX 78130 9 LEGEND LOCATION MAP INT E R S T A T E 3 5 SITE F M 3 0 0 9 FOUR O A K S L N OWNER/DEVELOPER: WATERFALL KID, LLC DANIEL MCCUTCHEN 125 ASH JUNIPER NEW BRAUNFELS, TX 78132 (737) 335-7731 ENGINEER/SURVEYOR: INK CIVIL SAM KNOTTS, P.E. - ENGINEER 2021 SH 46 W. STE 105. NEW BRAUNFELS, TX. 78132 (830) 358-7127 D.A. MAWYER LAND SURVEYING, INC. DREW MAWYER, R.P.L.S. - SURVEYOR 5151 W. SH46 NEW BRAUNFELS, TEXAS 78132 (210) 325-0858 3/14/2024 PROPOSED BUILDING 5,317 SF EXIT ONLY EXIT ONLY NO PARKING FIRE LANE NO PARKING FIRE LANE NO PARKING FIRE LANE NO PARKING FIRE LANE 12 FIRE SITE PLAN SHEET C.P.E. LOCATOR TELEPHONE LOCATOR TRENCH EXCAVATION SAFETY PROTECTION © NO DATE ISSUES AND REVISIONS BIG LEAGUE CAR WASH #4 GARDEN COMMERCIAL SUBDIVISION LOT 3, BLOCK 1 17969 N I35, SCHERTZ, TX OF 16 BIG LEAGUE CAR WASH 422 FM 306 NEW BRAUNFELS, TX 78130 LEGEND N (NON SPRINKLERED) 3/7/2024 PAINT (EXTERIOR)EP-1 EXTERIOR FINISH SELECTIONS METAL COMPONENTS MTL-1 MTL-2 MTL-3 MASONRY CMU-1 STOREFRONT SYSTEM SF-1 EIFS CAST STONE CS-1 CMU MORTAR: SPECTRUM, MEDIUM BLACK A.ALL EXTERIOR FINISHES, MATERIALS, AND SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. B.ALL ARCHITECTURAL CMU BLOCK SHALL BE INTEGRALLY COLORED, PRE-SEALED AT THE FACTORY, UTILIZE MATCHING SMOOTH FACE PRE-COLORED CMU WHERE SHOWN & WHERE COMPONENTS, FLASHING, COPINGS WILL ATTACH, TYPICAL. C.ALL STANDARD CMU (NON-INTEGRALLY COLORED) SHALL BE COMPLETELY COVERED. D.PROVIDE L&M AQUAPEL ON ALL CMU SURFACES PRIOR TO FINAL PAINT OR COVERING. E.PAINT ALL EXPOSED STEEL STRUCTURE AS SCHEDULED. F.ALL EXPOSED METAL FLASHING/TRIM PIECES SHALL BE PRE-FINISHED METAL. G.ALL CONNECTIONS, FASTENERS AND TRIMS FOR GALVANIZED ITEMS SHALL BE GALVANIZED OR STAINLESS STEEL. EXTERIOR FINISH SELECTIONS NOTES: TEXAS BUILDING PRODUCT STACKED BOND FRIO BURNISHED CLEAR ANODIZED ALUMINUM PAC CLAD INTERSTATE BLUE, 24 GA. MBCI, PBD PANEL, SILVER PAC CLAD SLATE GREY, 24 GA. SHERWIN WILLIAMS MACROPOXY PRIMER W/ BENJAMIN MOORE DOWNPOUR BLUE 2063-20 EFS-1 EFS-2 DRYVIT 2" SYTEM, FINESSE TEXTURE, BENJAMIN MOORE 2125-10 BLACK PANTHER DRYVIT 2" SYTEM, FINESSE TEXTURE, BENJAMIN MOORE HC-179 PLATINUM GREY CLADDING FC-1 EQUITONE NATURA N211 TEXAS BUILDING PRODUCTS, CHARCOAL EP-2 BENJAMIN MOORE 2125-10 BLACK PANTHER (DUMPSTER GATES AND DOOR) MTL-4 PRE -FINISHED GUTTERS AND DOWNSPOUTS MATCH CMU -1 B, C, D, E WINDOW TYPES A NOTES: 1. DIMENSIONS SHOWN ARE NOMINAL AND DO NOT SHOW REQUIRED GAPS TO MASONRY. PROVIDE SYSTEMS THAT FIT WITHIN COURSED MASONRY. VERIFY ALL OPENINGS PRIOR TO SHOP DRAWINGS AND FABRICATION. 2. ALL GLAZING IN CONDITIONED SPACES SHALL COMPLY WITH IECC STANDARDS FOR CLIMATE ZONE. REFER TO COMCHECK FOR U FACTOR AND SHGC. SHGC RATING NOT REQUIRED ON WINDOWS INTO TUNNEL. 3. PER SPECIFICATIONS, GLAZING THICKNESS TO BE DETERMINED BY GLAZING MANUFACTURER, TAKING INTO ACCOUNT WIND LOADS, GLAZING SIZE, AND GLAZING LOCATION. SHOP DRAWINGS SHALL BE PROVIDED TO ARCHITECT FOR APPROVAL. 4. PROVIDE SHIM AND SEALANT BETWEEN STOREFRONT SYSTEM AND ADJACENT BUILDING MATERIAL, TYP. 4 1/2" ANODIZED ALUMINUM STORE FRONT SYSTEM, 1" DOUBLE GLAZED INSULATED GUARDIAN GLASS SNR 43 ON CLEAR 4 1/2" ANODIZED ALUMINUM STORE FRONT SYSTEM, SINGLE GLAZED CLEAR INSTALL STOREFRONT FRAME WITH EXTERIOR FACING INWARD (WEEPS INTO TUNNEL) (OFFICE ->EXT) (TUNNEL -> EXT) F 4 1/2" ANODIZED ALUMINUM STORE FRONT SYSTEM, 1" DOUBLE GLAZED INSULATED, CLEAR GLAZING, NO FILM OR TINT (OFFICE-> TUNNEL) G (LOUVER) PREFINISHED ALUMINUM LOUVER SYSTEM, LF08 NAILOR, GALVALUME INSTALL STOREFRONT FRAME WITH EXTERIOR FACING INTO TUNNEL. (WEEPS INTO TUNNEL) EXPOSED EXTERIOR CONCRETE: ALL EXPOSED EXTERIOR CONCRETE ABOVE GRADE SHALL HAVE SMOOTH RUBBED FINISH. EXTERIOR MOCKUP WALL: CONTRACTOR TO PROVIDE AN EXTERIOR FINISH MOCK-UP WALL, 4' WIDE BY 6' HIGH MINIMUM, FOR OWNER AND/OR ARCHITECT APPROVAL PRIOR TO ANY EXTERIOR FINISH CONSTRUCTION. MOCK-UP WALL SHALL HAVE ALL EXTERIOR COMPONENTS REPRESENTED INCLUDING GROUT, SEALANTS, FLASHING, ETC.. EXTERIOR CMU FINISH: PROVIDE MATCHING SMOOTH FACE CMU AT ALL WALL MOUNTED LIGHT FIXTURES, CANOPIES, FACIA, FLASHING AND ALL WALL MOUNTED ITEMS REQUIRING A FLAT SURFACE FOR INSTALLATION TYPICAL. FINISH FLOOR 100' -0" SF-1 MTL-1 STEEL STRUCT EP-1 REF STRUCT TYP. CANOPY EP-1 CMU-1 MTL-1 MTL -1 FC -1 O.H. DOOR REF SCHEDULE T.O. MASONRY 114' -6" T.O. PARAPET 125' -2" T.O. STEEL 134' -4" T.O. CANOPY 112' -3" T.O. MASONRY 121' -10" RF -1 N5 A5.1 J5 A5.1 LIGHT FIXTURE REF. MEP TYP. MTL-4 D LIGHT FIXT REF MEP 13' - 4 1/4"22' - 8 1/4"1' - 4 3/4" FINISH FLOOR 100' -0" FINISH FLOOR 100' -0" SF-1 FC-1 CANOPY EP-1 MTL-3 EFS-1 EFS-2 MTL -1 MTL -1 CMU-1 MTL-1 STEEL STRUCT EP-1 REF STRUCT TYP MTL-2 CMU-1 T.O. MASONRY 114' -6" T.O. PARAPET 125' -2" T.O. STEEL 134' -4" T.O. MASONRY 121' -10" F9 A5.1F5 A5.1 LED LIGHT CONT FIXTURE TYP LIGHT FIXT REF MEP TYP MTL -4 TYP F10 A5.1 E 4' - 0"6' - 0"134' - 5 3/4"26' - 4 1/4"4' - 6 3/4" FINISH FLOOR 100' -0" MTL-1 CANOPY EP-1 SF-1 TYP. MTL-1 LOUVER TYP FC -1 MTL -3 EFS -1 SF-1 MTL-1 STEEL STRUCT EP-1 REF STRUCT MTL -2 CMU -1 F9 A5.1 F5 A5.1 CMU-1 CMU-1 MTL -4 TYPICAL FINISH FLOOR 100' -0" LIGHT FIXTURE REF. MEP, TYP. F10 A5.1 A B C G T.O. MASONRY 114' -6" T.O. PARAPET 125' -2" T.O. STEEL 134' -4" T.O. MASONRY 121' -10" 26' - 1 7/8"134' - 8 3/4"6' - 0"4' - 0" FINISH FLOOR 100' -0" FC -1 TYP. CMU-1 MTL-3 EFS-1 MTL-1 MTL-1 RF-3 SOFFIT PANEL STEEL STRUCT EP-1 REF STRUCT MTL-2 T.O. MASONRY 114' -6" T.O. PARAPET 125' -2" T.O. STEEL 134' -4" O.H. DOOR REF SCHEDULE N5 A5.1 J5 A5.1 LIGHT FIXT REF MEP TYP. MTL-4 1' - 10 1/4"25' - 4 7/8"1' - 3" 2' - 6" 6' - 8" 5' - 4" 4' - 5" 2' - 3" C 9' - 2" 2' - 4" 4' - 9" 2' - 1" 6' - 1"3' - 3" 9' - 4" B TT T T T G 7' - 4" 6' - 6" 2' - 8" 3' - 2" 8' - 8" EQ EQ EQ EQ 15' - 4" A T T T T 6' - 8" 6' - 6" 3' - 0" F T T 2' - 6" 4' - 0" 2' - 8" 1' - 10" 4' - 2" E 6' - 0" 3' - 2" 2' - 1" 7' - 1" 9' - 2" 3' - 3"2' - 2"3' - 3" 8' - 8" 2' - 1" 4' - 7" 6' - 8" 2' - 6" D T TT T THIS SYMBOL DENOTES TEMPERED GLASS T 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 A B C D E F G H J K L M N Project No. Date REVISIONS No.DATE NOTE Trent W. Clark, Architect TX Registration # 17084 PRELIMINARY NOT FOR CONSTRUCTION THESE DRAWINGS ARE INCOMPLETE AND MAY NOT BE USED FOR REGULATORY APPROVAL, PERMIT, OR CONSTRUCTION. A PLUS DESIGN GROUP ARCHITECTURE INTERIORS CONSTRUCTION 972-724-4440 APDG.US COPYRIGHT A PLUS DESIGN GROUP 2024© A N E W C A R W A S H F O R : A3.1 EXTERIOR ELEVATIONS 23-0526 01-22-24 17 9 6 9 N I - 3 5 SC H E R T Z , T X . 7 8 1 5 4 BI G L E A G U E 1/8" = 1'-0"F4 WEST ELEVATION 1/8" = 1'-0"N4 SOUTH ELEVATION 1/8" = 1'-0"J4 NORTH ELEVATION 1/8" = 1'-0"F9 EAST ELEVATION 1/8" = 1'-0"B1 WINDOW ELEVATIONS EXIT ONLY EXIT ONLY C.P.E. LOCATOR TELEPHONE LOCATOR TRENCH EXCAVATION SAFETY PROTECTION LEGEND INCHES REMOVED INCHES SAVED INCHES TO BE MITIGATED 0 353 0 SHEET C.P.E. LOCATOR TELEPHONE LOCATOR TRENCH EXCAVATION SAFETY PROTECTION © NO DATE ISSUES AND REVISIONS BIG LEAGUE CAR WASH #4 GARDEN COMMERCIAL SUBDIVISION LOT 3, BLOCK 1 17969 N I35, SCHERTZ, TX OF 16 BIG LEAGUE CAR WASH 422 FM 306 NEW BRAUNFELS, TX 78130 5 3/7/2024 05/03/2024 4:28:04 PM Ap Approved By: Daisy Marquez, Planner Planning & Community Development